Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull

The purpose of the present theoretical study was to examine the spatial resolution of electroencephalography (EEG) by means of the accuracy of the inverse cortical EEG solution. The study focused on effect of the amount of measurement noise and the number of electrodes on the spatial resolution with different resistivity ratios for the scalp, skull and brain. The results show that if the relative skull resistivity is lower than earlier believed, the spatial resolution of different electrode systems is less sensitive to the measurement noise. Furthermore, there is then also greater advantage to be obtained with high-resolution EEG at realistic noise levels

[1]  Jaakko Malmivuo,et al.  Effect of skull resistivity on the spatial resolutions of EEG and MEG , 2004, IEEE Transactions on Biomedical Engineering.

[2]  Bin He,et al.  Estimating cortical potentials from scalp EEGs in a realistically shaped inhomogeneous head model by means of the boundary element method , 1999, IEEE Transactions on Biomedical Engineering.

[3]  J. Fermaglich Electric Fields of the Brain: The Neurophysics of EEG , 1982 .

[4]  S J Walker,et al.  Forward and Inverse Electrocardiographic Calculations Using Resistor Network Models of the Human Torso , 1987, Circulation research.

[5]  Christoph M. Michel,et al.  Epileptic source localization with high density EEG: how many electrodes are needed? , 2003, Clinical Neurophysiology.

[6]  P. V. van Rijen,et al.  Measurement of the Conductivity of Skull, Temporarily Removed During Epilepsy Surgery , 2004, Brain Topography.

[7]  D. A. Driscoll,et al.  EEG electrode sensitivity--an application of reciprocity. , 1969, IEEE transactions on bio-medical engineering.

[8]  P. Kauppinen,et al.  Effects of tissue resistivities on electroencephalogram sensitivity distribution , 1999, Medical & Biological Engineering & Computing.

[9]  M. Murray,et al.  EEG source imaging , 2004, Clinical Neurophysiology.

[10]  J Malmivuo,et al.  A software implementation for detailed volume conductor modelling in electrophysiology using finite difference method. , 1999, Computer methods and programs in biomedicine.

[11]  Robert Plonsey,et al.  Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields , 1995 .

[12]  Bin He,et al.  A computer simulation study of cortical imaging from scalp potentials , 1998, IEEE Transactions on Biomedical Engineering.

[13]  Jaakko Malmivuo,et al.  Effect of skull resistivity and measurement noise on the spatial resolution of EEG , 2005 .

[14]  Jaakko Malmivuo,et al.  Effect of electrode density and measurement noise on the spatial resolution of cortical potential distribution , 2004, IEEE Transactions on Biomedical Engineering.

[15]  R. B. Kearfott,et al.  Numerical tests of a method for simulating electrical potentials on the cortical surface , 1991, IEEE Transactions on Biomedical Engineering.

[16]  O. Dossel,et al.  Filtering characteristics of the human body and reconstruction limits in the inverse problem of electrocardiography , 1998, Computers in Cardiology 1998. Vol. 25 (Cat. No.98CH36292).

[17]  Per Christian Hansen,et al.  Rank-Deficient and Discrete Ill-Posed Problems , 1996 .

[18]  D. B. Smith,et al.  Experimental tests of the cortical imaging technique-applications to the response to median nerve stimulation and the localization of epileptiform discharges , 1992, IEEE Transactions on Biomedical Engineering.

[19]  John W Belliveau,et al.  Monte Carlo simulation studies of EEG and MEG localization accuracy , 2002, Human brain mapping.

[20]  A Gevins,et al.  High resolution EEG: 124-channel recording, spatial deblurring and MRI integration methods. , 1994, Electroencephalography and clinical neurophysiology.

[21]  Thom F. Oostendorp,et al.  The conductivity of the human skull: results of in vivo and in vitro measurements , 2000, IEEE Transactions on Biomedical Engineering.

[22]  J. Le,et al.  Method to reduce blur distortion from EEG's using a realistic head model , 1993, IEEE Transactions on Biomedical Engineering.

[23]  J. Malmivuo,et al.  Sensitivity distributions of EEG and MEG measurements , 1997, IEEE Transactions on Biomedical Engineering.

[24]  W. Drongelen,et al.  Estimation of in vivo human brain-to-skull conductivity ratio from simultaneous extra- and intra-cranial electrical potential recordings , 2005, Clinical Neurophysiology.