Enhanced chemiluminescence as a means of increasing the sensitivity of western blot assays for HIV antibody.

Chemiluminescence indicator systems offer several advantages for diagnostic assays and have been used successfully to increase the sensitivity of antibody and antigen assays. A technique of enhanced chemiluminescence (ECL) was applied as a replacement for routine chromogenic substrates on HIV-1 Western blots. The results indicated that the enhanced chemiluminescence detection system increased the sensitivity by greater than 10-fold over routine chromogenic indicator systems when testing diluted, reactive sera. When testing 9 seroconversion panels, the use of ECL indicated that early detection of HIV infection was elicited in six panels up to 31 days (average 11.4 days) prior to detection by routine FDA-licensed Western blots, and could be detected in all panels up to 43 days (average 18.8 days) prior to detection by in-house Western blots. In no case was the ECL Western blot system less sensitive than any of the chromogenic Western blots, and in several cases the maximum potential of the ECL system for early detection of antibody could not be determined. The ECL system was capable of detecting antibodies to envelope antigens at a 20-fold increase over chromogenic Western blots. The time of detection of seropositivity by the ECL Western blot was equal to that of most ELISAs in 5 panels and was 31 days earlier than ELISA in one panel. Permanent documentation of Western blot profiles was accomplished using a simple instamatic camera system capable of detecting the chemiluminescence signal, and blots could be re-probed using a second sample.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  I. Bronstein,et al.  1,2-dioxetanes: novel chemiluminescent enzyme substrates. Applications to immunoassays. , 1989, Journal of bioluminescence and chemiluminescence.

[2]  K. Hyams,et al.  Evaluation of five hepatitis C virus screening tests and two supplemental assays: performance when testing sera from sexually transmitted diseases clinic attendees in the USA. , 1993, Clinical and diagnostic virology.

[3]  B. Strehler,et al.  Firefly luminescence in the study of energy transfer mechanisms. I. Substrate and enzyme determination. , 1952, Archives of biochemistry and biophysics.

[4]  L. Heyndrickx,et al.  Confirmation and differentiation of antibodies to human immunodeficiency virus 1 and 2 with a strip-based assay including recombinant antigens and synthetic peptides. , 1991, Clinical chemistry.

[5]  C. Ewing,et al.  The erasable Western blot. , 1987, Analytical biochemistry.

[6]  L J Kricka,et al.  Chemiluminescent and bioluminescent techniques. , 1991, Clinical chemistry.

[7]  R. Wilks,et al.  Distinguishing between HTLV-I and HTLV-II by western blot , 1990, The Lancet.

[8]  C. Milstein,et al.  Luminescent detection method for immunodot, Western, and Southern blots. , 1986, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[9]  I. Weeks,et al.  Chemiluminescence immunoassay: an overview. , 1986, Clinical science.

[10]  L. Giunchedi,et al.  A chemiluminescent immunoassay for the diagnosis of grapevine closteroviruses on nitrocellulose membrane. , 1993, Journal of virological methods.

[11]  D. Armstrong,et al.  Differences in human immunodeficiency virus type 1 (HIV-1) anti-p24 reactivities in serum of HIV-1-infected and uninfected subjects: analysis of indeterminate western blot reactions. , 1991, The Journal of infectious diseases.

[12]  D. Watts,et al.  Retroviral Testing: Essentials For Quality Control and Laboratory Diagnosis , 1992 .

[13]  D. Burke Laboratory diagnosis of human immunodeficiency virus infection. , 1989, Clinics in laboratory medicine.

[14]  N. Constantine Serologic tests for the retroviruses: approaching a decade of evolution. , 1993, AIDS.

[15]  L. Kricka,et al.  Improved chemiluminescent detection of alkaline phosphatase. , 1990, BioTechniques.

[16]  Richard F. Dudley Chemiluminescence Immunoassay: An Alternative to RIA , 1990 .

[17]  R. Valdiserri,et al.  Interpretation and Use of the Western Blot Assay for Serodiagnosis of Human Immunodeficiency Virus Type 1 Infections , 1989, Infection Control & Hospital Epidemiology.

[18]  R. Ashley,et al.  Highly sensitive enhanced chemiluminescence immunodetection method for herpes simplex virus type 2 Western immunoblot , 1992, Journal of clinical microbiology.