The electrical conductivity of human cerebrospinal fluid at body temperature

The electrical conductivity of human cerebrospinal fluid (CSF) from seven patients was measured at both room temperature (25/spl deg/C) and body temperature (37/spl deg/C). Across the frequency range of 10 Hz-10 kHz, room temperature conductivity was 1.45 S/m, but body temperature conductivity was 1.79 S/m, approximately 23% higher. Modelers of electrical sources in the human brain have underestimated human CSF conductivity by as much as 44% for nearly two decades, and this should be corrected to increase the accuracy of source localization models.

[1]  G. Crile,et al.  THE ELECTRICAL CONDUCTIVITY OF ANIMAL TISSUES UNDER NORMAL AND PATHOLOGICAL CONDITIONS , 1922 .

[2]  H. Merritt,et al.  The cerebrospinal fluid , 1938 .

[3]  H. C. Burger,et al.  Specific electric resistance of body tissues. , 1961, Physics in medicine and biology.

[4]  L. Geddes Electrodes and the measurement of bioelectric events , 1972 .

[5]  Anthony Sances,et al.  The Contributions of Intracerebral Currents to the EEG and Evoked Potentials , 1978, IEEE Transactions on Biomedical Engineering.

[6]  D. Cohen,et al.  Comparison of the magnetoencephalogram and electroencephalogram. , 1979, Electroencephalography and clinical neurophysiology.

[7]  Anistropy and Postmortem Changes in the Electrical Resistivity and Capacitance of Skeletal Muscle , 1980 .

[8]  J. G. Webster,et al.  Impedance of Skeletal Muscle from 1 Hz to 1 MHz , 1984, IEEE Transactions on Biomedical Engineering.

[9]  Charles Polk,et al.  CRC Handbook of Biological Effects of Electromagnetic Fields , 1986 .

[10]  Cees J. Stok,et al.  The influence of model parameters on EEG/MEG single dipole source estimation , 1987, IEEE Transactions on Biomedical Engineering.

[11]  Onno W. Weier,et al.  On the numerical accuracy of the boundary element method (EEG application) , 1989, IEEE Transactions on Biomedical Engineering.

[12]  M. Hämäläinen,et al.  Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data , 1989, IEEE Transactions on Biomedical Engineering.

[13]  R. Srebro Realistic modeling of vep topography , 1990, Vision Research.

[14]  C. Nicholson,et al.  Distortion of magnetic evoked fields and surface potentials by conductivity differences at boundaries in brain tissue. , 1990, Biophysical journal.

[15]  K. W. Pratt,et al.  Proposed New Electrolytic Conductivity Primary Standards for KCl Solutions , 1991, Journal of research of the National Institute of Standards and Technology.

[16]  D H Fender,et al.  Models of the Human Brain and the Surrounding Media: Their Influence on the Reliability of Source Localization , 1991, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[17]  A. van Oosterom,et al.  Computation of the potential distribution in a four-layer anisotropic concentric spherical volume conductor , 1992, IEEE Transactions on Biomedical Engineering.

[18]  V. Jousmäki,et al.  Effects of 45-Hz magnetic fields on the functional state of the human brain. , 1993, Bioelectromagnetics.

[19]  J. Le,et al.  Method to reduce blur distortion from EEG's using a realistic head model , 1993, IEEE Transactions on Biomedical Engineering.

[20]  S. Harik Cerebrospinal Fluid in Diseases of the Nervous System, 2nd Ed. , 1994, Neurology.

[21]  B. Lutkenhoner,et al.  Localization of a dipolar source in a skull phantom: realistic versus spherical model , 1994, IEEE Transactions on Biomedical Engineering.

[22]  P. Berg,et al.  A fast method for forward computation of multiple-shell spherical head models. , 1994, Electroencephalography and clinical neurophysiology.

[23]  J. Haueisen,et al.  Influence of tissue resistivities on neuromagnetic fields and electric potentials studied with a finite element model of the head , 1997, IEEE Transactions on Biomedical Engineering.