Adaptive beamlet-based finite-size pencil beam dose calculation for independent verification of IMRT and VMAT.

PURPOSE The use of sophisticated dose calculation procedure in modern radiation therapy treatment planning is inevitable in order to account for complex treatment fields created by multileaf collimators (MLCs). As a consequence, independent volumetric dose verification is time consuming, which affects the efficiency of clinical workflow. In this study, the authors present an efficient adaptive beamlet-based finite-size pencil beam (AB-FSPB) dose calculation algorithm that minimizes the computational procedure while preserving the accuracy. METHODS The computational time of finite-size pencil beam (FSPB) algorithm is proportional to the number of infinitesimal and identical beamlets that constitute an arbitrary field shape. In AB-FSPB, dose distribution from each beamlet is mathematically modeled such that the sizes of beamlets to represent an arbitrary field shape no longer need to be infinitesimal nor identical. As a result, it is possible to represent an arbitrary field shape with combinations of different sized and minimal number of beamlets. In addition, the authors included the model parameters to consider MLC for its rounded edge and transmission. RESULTS Root mean square error (RMSE) between treatment planning system and conventional FSPB on a 10 × 10 cm(2) square field using 10 × 10, 2.5 × 2.5, and 0.5 × 0.5 cm(2) beamlet sizes were 4.90%, 3.19%, and 2.87%, respectively, compared with RMSE of 1.10%, 1.11%, and 1.14% for AB-FSPB. This finding holds true for a larger square field size of 25 × 25 cm(2), where RMSE for 25 × 25, 2.5 × 2.5, and 0.5 × 0.5 cm(2) beamlet sizes were 5.41%, 4.76%, and 3.54% in FSPB, respectively, compared with RMSE of 0.86%, 0.83%, and 0.88% for AB-FSPB. It was found that AB-FSPB could successfully account for the MLC transmissions without major discrepancy. The algorithm was also graphical processing unit (GPU) compatible to maximize its computational speed. For an intensity modulated radiation therapy (∼12 segments) and a volumetric modulated arc therapy fields (∼90 control points) with a 3D grid size of 2.0 × 2.0 × 2.0 mm(3), dose was computed within 3-5 and 10-15 s timeframe, respectively. CONCLUSIONS The authors have developed an efficient adaptive beamlet-based pencil beam dose calculation algorithm. The fast computation nature along with GPU compatibility has shown better performance than conventional FSPB. This enables the implementation of AB-FSPB in the clinical environment for independent volumetric dose verification.

[1]  Steve B Jiang,et al.  GPU-based ultra-fast dose calculation using a finite size pencil beam model. , 2009, Physics in medicine and biology.

[2]  Jin Sung Kim,et al.  Motion-map constrained image reconstruction (MCIR): application to four-dimensional cone-beam computed tomography. , 2013, Medical physics.

[3]  Steve B. Jiang,et al.  Liver motion during cone beam computed tomography guided stereotactic body radiation therapy. , 2012, Medical physics.

[4]  E. B. Butler,et al.  Intensity modulated radiation therapy (IMRT): a new promising technology in radiation oncology. , 1999, The oncologist.

[5]  Steve B. Jiang,et al.  Development of a GPU-based Monte Carlo dose calculation code for coupled electron–photon transport , 2009, Physics in medicine and biology.

[6]  T. Kron,et al.  A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer , 2012, Radiation oncology.

[7]  Jin Sung Kim,et al.  Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT. , 2012, Medical physics.

[8]  Benoît Ozell,et al.  A convolution-superposition dose calculation engine for GPUs. , 2010, Medical physics.

[9]  Robert D. Howe,et al.  GPU based real-time instrument tracking with three-dimensional ultrasound , 2007, Medical Image Anal..

[10]  Dwight E Heron,et al.  A dose verification method using a monitor unit matrix for dynamic IMRT on Varian linear accelerators , 2005, Physics in medicine and biology.

[11]  D A Jaffray,et al.  The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. , 1998, Physics in medicine and biology.

[12]  G C Sharp,et al.  GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration , 2007, Physics in medicine and biology.

[13]  K. Jabbari Review of Fast Monte Carlo Codes for Dose Calculation in Radiation Therapy Treatment Planning , 2011, Journal of medical signals and sensors.

[14]  G T Chen,et al.  A monitor unit verification calculation in intensity modulated radiotherapy as a dosimetry quality assurance. , 2000, Medical physics.

[15]  M Alber,et al.  A finite size pencil beam algorithm for IMRT dose optimization: density corrections , 2007, Physics in medicine and biology.

[16]  Xing Wu,et al.  A global optimization method for three-dimensional conformal radiotherapy treatment planning , 2001, Physics in medicine and biology.

[17]  K Parodi,et al.  Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy: one-year experimental results and Monte Carlo analysis of the involved uncertainties , 2013, Physics in medicine and biology.

[18]  Steve B. Jiang,et al.  Ultra-Fast Digital Tomosynthesis Reconstruction Using General-Purpose GPU Programming for Image-Guided Radiation Therapy , 2011, Technology in cancer research & treatment.

[19]  Y. Zhu,et al.  Refinements of the finite-size pencil beam model of three-dimensional photon dose calculation. , 1997, Medical physics.

[20]  M Oldham,et al.  The optimization and inherent limitations of 3D conformal radiotherapy treatment plans of the prostate. , 1995, The British journal of radiology.

[21]  A Brahme,et al.  Optimization of radiation therapy and the development of multi-leaf collimation. , 1993, International journal of radiation oncology, biology, physics.

[22]  G T Chen,et al.  Implementation of three dimensional conformal radiation therapy: prospects, opportunities, and challenges. , 1995, International journal of radiation oncology, biology, physics.

[23]  A. Ahnesjö,et al.  A pencil beam model for photon dose calculation. , 1992, Medical physics.

[24]  S Webb Optimization of conformal radiotherapy dose distributions by simulated annealing: 2. Inclusion of scatter in the 2D technique. , 1991, Physics in medicine and biology.

[26]  T LoSasso,et al.  Testing of dynamic multileaf collimation. , 1996, Medical physics.

[27]  Bo Lu,et al.  Comparison of analytic source models for head scatter factor calculation and planar dose calculation for IMRT , 2008, Physics in medicine and biology.

[28]  An MLC calibration method using a detector array. , 2009, Medical physics.

[29]  James M. Galvin,et al.  Initiation of multileaf collimator conformal radiation therapy , 1993 .

[30]  Steve B. Jiang,et al.  GPU-based ultrafast IMRT plan optimization , 2009, Physics in medicine and biology.

[31]  J. Madden,et al.  Potential for improved intelligence quotient using volumetric modulated arc therapy compared with conventional 3-dimensional conformal radiation for whole-ventricular radiation in children. , 2012, International journal of radiation oncology, biology, physics.

[32]  Jin Sung Kim,et al.  Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT. , 2011, Medical physics.

[33]  Russell H. Taylor,et al.  Real-time dose computation: GPU-accelerated source modeling and superposition/convolution. , 2010, Medical physics.

[34]  J J Battista,et al.  Dose calculations using convolution and superposition principles: the orientation of dose spread kernels in divergent x-ray beams. , 1993, Medical physics.

[35]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[36]  Cedric X. Yu,et al.  Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. , 2003, Medical physics.

[37]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.

[38]  L. Xing,et al.  Independent monitor unit calculation for intensity modulated radiotherapy using the MIMiC multileaf collimator. , 2002, Medical physics.

[39]  J. Lutterbach,et al.  Impact of Gantry Rotation Time on Plan Quality and Dosimetric Verification – Volumetric Modulated Arc Therapy (VMAT) vs. Intensity Modulated Radiotherapy (IMRT) , 2011, Strahlentherapie und Onkologie.

[40]  S. Senan,et al.  Volumetric modulated arc therapy versus conventional intensity modulated radiation therapy for stereotactic spine radiotherapy: a planning study and early clinical data. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[41]  Yixue Chen,et al.  'A finite size pencil beam for IMRT dose optimization'--a simpler analytical function for the finite size pencil beam kernel. , 2006, Physics in medicine and biology.

[42]  Steve B. Jiang,et al.  GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation , 2010 .

[43]  Linda Hong,et al.  The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator. , 2003, Medical physics.

[44]  N Papanikolaou,et al.  Calculation of portal dose using the convolution/superposition method. , 1996, Medical physics.

[45]  Tufve Nyholm,et al.  Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience. , 2007, Physics in medicine and biology.

[46]  P. Biggs Evidence for a significant timer error on a linear accelerator: consequences for a special therapy application. , 1998, Physics in medicine and biology.

[47]  Bongyong Song,et al.  GateCT™ surface tracking system for respiratory signal reconstruction in 4DCT imaging. , 2011, Medical physics.

[48]  Li Chen,et al.  Independent verification of monitor unit calculation for radiation treatment planning system. , 2010, Chinese journal of cancer.

[49]  M Alber,et al.  A finite size pencil beam for IMRT dose optimization , 2005, Physics in medicine and biology.

[50]  C. De Wagter,et al.  An inter-centre quality assurance network for IMRT verification: results of the ESTRO QUASIMODO project. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[51]  Deshan Yang,et al.  Automated radiotherapy treatment plan integrity verification. , 2012, Medical physics.

[52]  J D Bourland,et al.  A finite-size pencil beam model for photon dose calculations in three dimensions. , 1992, Medical physics.

[53]  Joao Seco,et al.  Evaluation of two methods of predicting MLC leaf positions using EPID measurements. , 2006, Medical physics.

[54]  G. Starkschall,et al.  A two-dimensional pencil-beam algorithm for calculation of arc electron dose distributions. , 1989, Physics in medicine and biology.

[55]  Xun Jia,et al.  GPU-based fast gamma index calculation. , 2011, Physics in medicine and biology.

[56]  I Martínez-Rovira,et al.  Monte Carlo-based dose calculation engine for minibeam radiation therapy. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[57]  Y Chen,et al.  Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm. , 2000, Physics in medicine and biology.

[58]  Xun Jia,et al.  A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation. , 2011, Physics in medicine and biology.

[59]  J. Palta,et al.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. , 1994, Medical physics.

[60]  IMRT: high-definition radiation therapy in a community hospital. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[61]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[62]  James L. Bedford,et al.  Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study , 2008, Acta oncologica.