Contrast-enhanced ultrasound and/or colour duplex ultrasound for surveillance after endovascular abdominal aortic aneurysm repair: a systematic review and economic evaluation.

BACKGROUND Endovascular abdominal aortic aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) is less invasive than open surgery, but may be associated with important complications. Patients receiving EVAR require long-term surveillance to detect abnormalities and direct treatments. Computed tomography angiography (CTA) has been the most common imaging modality adopted for EVAR surveillance, but it is associated with repeated radiation exposure and the risk of contrast-related nephropathy. Colour duplex ultrasound (CDU) and, more recently, contrast-enhanced ultrasound (CEU) have been suggested as possible, safer, alternatives to CTA. OBJECTIVES To assess the clinical effectiveness and cost-effectiveness of imaging strategies, using either CDU or CEU alone or in conjunction with plain radiography, compared with CTA for EVAR surveillance. DATA SOURCES Major electronic databases were searched, including MEDLINE, EMBASE, Science Citation Index, Scopus' Articles-in-Press, Cochrane Central Register of Controlled Trials (CENTRAL), Database of Abstracts of Reviews of Effects (DARE) and NHS Economic Evaluation Database from 1996 onwards. We also searched for relevant ongoing studies and conference proceedings. The final searches were undertaken in September 2016. METHODS We conducted a systematic review of randomised controlled trials and cohort studies of patients with AAAs who were receiving surveillance using CTA, CDU and CEU with or without plain radiography. Three reviewers were involved in the study selection, data extraction and risk-of-bias assessment. We developed a Markov model based on five surveillance strategies: (1) annual CTA; (2) annual CDU; (3) annual CEU; (4) CDU together with CTA at 1 year, followed by CDU on an annual basis; and (5) CEU together with CTA at 1 year, followed by CEU on an annual basis. All of these strategies also considered plain radiography on an annual basis. RESULTS We identified two non-randomised comparative studies and 25 cohort studies of interventions, and nine systematic reviews of diagnostic accuracy. Overall, the proportion of patients who required reintervention ranged from 1.1% (mean follow-up of 24 months) to 23.8% (mean follow-up of 32 months). Reintervention was mainly required for patients with thrombosis and types I-III endoleaks. All-cause mortality ranged from 2.7% (mean follow-up of 24 months) to 42% (mean follow-up of 54.8 months). Aneurysm-related mortality occurred in < 1% of the participants. Strategies based on early and mid-term CTA and/or CDU and long-term CDU surveillance were broadly comparable with those based on a combination of CTA and CDU throughout the follow-up period in terms of clinical complications, reinterventions and mortality. The economic evaluation showed that a CDU-based strategy generated lower expected costs and higher quality-adjusted life-year (QALYs) than a CTA-based strategy and has a 63% probability of being cost-effective at a £30,000 willingness-to-pay-per-QALY threshold. A CEU-based strategy generated more QALYs, but at higher costs, and became cost-effective only for high-risk patient groups. LIMITATIONS Most studies were rated as being at a high or moderate risk of bias. No studies compared CDU with CEU. Substantial clinical heterogeneity precluded a formal synthesis of results. The economic model was hindered by a lack of suitable data. CONCLUSIONS Current surveillance practice is very heterogeneous. CDU may be a safe and cost-effective alternative to CTA, with CTA being reserved for abnormal/inconclusive CDU cases. FUTURE WORK Research is needed to validate the safety of modified, more-targeted surveillance protocols based on the use of CDU and CEU. The role of radiography for surveillance after EVAR requires clarification. STUDY REGISTRATION This study is registered as PROSPERO CRD42016036475. FUNDING The National Institute for Health Research Health Technology Assessment programme.

[1]  Michael J Sweeting,et al.  Endovascular versus open repair of abdominal aortic aneurysm in 15-years' follow-up of the UK endovascular aneurysm repair trial 1 (EVAR trial 1): a randomised controlled trial , 2016, The Lancet.

[2]  A. Karthikesalingam,et al.  Multicentre Post-EVAR Surveillance Evaluation Study (EVAR-SCREEN). , 2019, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[3]  G. Pratesi,et al.  FT11. The Influence of the Timing of Onset of Type II Endoleak on the Late Outcomes of Endovascular Repair of Abdominal Aortic Aneurysms , 2016 .

[4]  M. Boult,et al.  Predictors of 1-Year Survival After Endovascular Aneurysm Repair. , 2016, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[5]  Charles M. LoPresti,et al.  Contrast-enhanced ultrasound after endovascular aortic repair-current status and future perspectives. , 2015, Cardiovascular diagnosis and therapy.

[6]  C. Catalano,et al.  EVAR: Benefits of CEUS for monitoring stent-graft status. , 2015, European journal of radiology.

[7]  B. Hill,et al.  Type II endoleak with or without intervention after endovascular aortic aneurysm repair does not change aneurysm-related outcomes despite sac growth. , 2015, Journal of vascular surgery.

[8]  S. Neequaye,et al.  Late Rupture of Abdominal Aortic Aneurysm After Previous Endovascular Repair , 2015, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[9]  T. Bisdas,et al.  The PROTAGORAS study to evaluate the performance of the Endurant stent graft for patients with pararenal pathologic processes treated by the chimney/snorkel endovascular technique. , 2015, Journal of vascular surgery.

[10]  A. Banerjee,et al.  Age‐specific incidence, risk factors and outcome of acute abdominal aortic aneurysms in a defined population , 2015, The British journal of surgery.

[11]  B. Hill,et al.  A multiregional registry experience using an electronic medical record to optimize data capture for longitudinal outcomes in endovascular abdominal aortic aneurysm repair. , 2015, Journal of vascular surgery.

[12]  J. Mancini,et al.  Aneurysm sac shrinkage after endovascular repair: predictive factors and long-term follow-up. , 2015, Annals of vascular surgery.

[13]  J. Becquemin,et al.  Predictive factors for limb occlusions after endovascular aneurysm repair. , 2015, Journal of vascular surgery.

[14]  B. Hill,et al.  Adherence to endovascular aortic aneurysm repair device instructions for use guidelines has no impact on outcomes. , 2015, Journal of vascular surgery.

[15]  A. Karthikesalingam,et al.  International validation of a risk score for complications and reinterventions after endovascular aneurysm repair , 2015, The British journal of surgery.

[16]  Spencer S. Kirk,et al.  From the Midwestern Vascular Surgical Society Role of type II endoleak in sac regression after endovascular repair of infrarenal abdominal aortic aneurysms , 2015 .

[17]  A. Thakor,et al.  Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications. , 2015, Clinical radiology.

[18]  J. Teijink,et al.  Risk factors for proximal neck complications after endovascular aneurysm repair using the endurant stentgraft. , 2015, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[19]  A. Kordzadeh,et al.  Contrast-enhanced ultrasound (CEUS) versus computed tomography angiography (CTA) in detection of endoleaks in post-EVAR patients. Are delayed type II endoleaks being missed? A systematic review and meta-analysis , 2015, Journal of Ultrasound.

[20]  B. Hill,et al.  Early and delayed rupture after endovascular abdominal aortic aneurysm repair in a 10-year multicenter registry. , 2014, Journal of vascular surgery.

[21]  A. Freyrie,et al.  Results of the endovascular abdominal aortic aneurysm repair using the Anaconda aortic endograft. , 2014, Journal of vascular surgery.

[22]  T. Bisdas,et al.  Durability of the Endurant stent graft in patients undergoing endovascular abdominal aortic aneurysm repair. , 2014, Journal of vascular surgery.

[23]  N. Kansal,et al.  Essentials of endovascular abdominal aortic aneurysm repair imaging: postprocedure surveillance and complications. , 2014, AJR. American journal of roentgenology.

[24]  R. Goldberg,et al.  Follow-up compliance after endovascular abdominal aortic aneurysm repair in Medicare beneficiaries. , 2014, Journal of vascular surgery.

[25]  Georgios I. Karaolanis,et al.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now? , 2014, International Journal of Angiology.

[26]  Anahita Dua,et al.  Epidemiology of aortic aneurysm repair in the United States from 2000 to 2010. , 2014, Journal of vascular surgery.

[27]  D. Tse,et al.  Surveillance After Endovascular Abdominal Aortic Aneurysm Repair , 2014, CardioVascular and Interventional Radiology.

[28]  S. Wilson,et al.  Surveillance computed tomographic arteriogram does not change management before 3 years in patients who have a normal post-EVAR study. , 2014, Annals of vascular surgery.

[29]  C. Murray,et al.  Estimation of global and regional incidence and prevalence of abdominal aortic aneurysms 1990 to 2010. , 2014, Global heart.

[30]  B. Hill,et al.  Abstract 16031: Aligning Information Technology With Longitudinal Outcomes Surveillance: A Multiregional Vascular Registry Experience , 2013 .

[31]  S. Vallabhaneni,et al.  Defining a role for contrast-enhanced ultrasound in endovascular aneurysm repair surveillance. , 2013, Journal of vascular surgery.

[32]  R. Edwards,et al.  Surveillance of patients post-endovascular abdominal aortic aneurysm repair (EVAR). A web-based survey of practice in the UK. , 2013, Clinical radiology.

[33]  A. Carriero,et al.  Endovascular treatment of abdominal aortic aneurysms: 6 years of experience at a single centre , 2013, La radiologia medica.

[34]  P. Hayes,et al.  Comparison of the Endurant Bifurcated Endograft vs. Aortouni-iliac Stent-Grafting in Patients With Abdominal Aortic Aneurysms: Experience From the ENGAGE Registry , 2013, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[35]  L. E. Staxrud,et al.  Review of postoperative CT and ultrasound for endovascular aneurysm repair using Talent stent graft: Can we simplify the surveillance protocol and reduce the number of CT scans? , 2013, Acta radiologica.

[36]  David Murray,et al.  A meta-analysis of outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile and friendly neck anatomy. , 2013, Journal of vascular surgery.

[37]  T. Rand,et al.  Quality Improvement Guidelines for Imaging Detection and Treatment of Endoleaks following Endovascular Aneurysm Repair (EVAR) , 2013, CardioVascular and Interventional Radiology.

[38]  A. Karthikesalingam,et al.  Systematic review and meta‐analysis of duplex ultrasonography, contrast‐enhanced ultrasonography or computed tomography for surveillance after endovascular aneurysm repair , 2012, The British journal of surgery.

[39]  D. Böckler,et al.  Early results from the ENGAGE registry: real-world performance of the Endurant Stent Graft for endovascular AAA repair in 1262 patients. , 2012, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[40]  J. Slaven,et al.  Estimating the risk of solid organ malignancy in patients undergoing routine computed tomography scans after endovascular aneurysm repair. , 2012, Journal of vascular surgery.

[41]  P. Geisbüsch,et al.  Current clinical practice in postoperative endovascular aneurysm repair imaging surveillance. , 2012, Journal of vascular and interventional radiology : JVIR.

[42]  Bradley Hill,et al.  Ten-year results of endovascular abdominal aortic aneurysm repair from a large multicenter registry. , 2012, Journal of vascular surgery.

[43]  L. Lawler,et al.  Use of colour duplex ultrasound as a first line surveillance tool following EVAR is associated with a reduction in cost without compromising accuracy. , 2012, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[44]  A. S. Blom,et al.  Duplex ultrasound imaging to detect limb stenosis or kinking of endovascular device. , 2012, Journal of vascular surgery.

[45]  Alan Karthikesalingam,et al.  Predictive Value of Peak Systolic Velocity for the Development of Graft Limb Complications After Endovascular Aneurysm Repair , 2012, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[46]  D. Reid,et al.  Early clinical experience with the Anaconda re-deployable endograft in 106 patients with abdominal aortic aneurism: the west of Scotland Anaconda registry , 2012, Scottish medical journal.

[47]  F. Setacci,et al.  Surveillance imaging modality does not affect detection rate of asymptomatic secondary interventions following EVAR. , 2012, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[48]  M. Bots,et al.  Annual rupture risk of abdominal aortic aneurysm enlargement without detectable endoleak after endovascular abdominal aortic repair. , 2011, Journal of vascular surgery.

[49]  M M Thompson,et al.  Heterogeneity in surveillance after endovascular aneurysm repair in the UK. , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[50]  M. Björck,et al.  Treatment of abdominal aortic aneurysm in nine countries 2005-2009: a vascunet report. , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[51]  P. Harris,et al.  Reprinted article "Realistic expectations for patients with stent-graft treatment of abdominal aortic aneurysms. Results of a European multicentre registry". , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[52]  S. Vallabhaneni,et al.  Surveillance after EVAR based on duplex ultrasound and abdominal radiography. , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[53]  F. Sorba,et al.  Endovascular aneurysm repair: experience of 12 years in a single institution , 2011 .

[54]  M. Clarke,et al.  Methodology in conducting a systematic review of systematic reviews of healthcare interventions , 2011, BMC medical research methodology.

[55]  S. Rose,et al.  Clinical practice guidelines for endovascular abdominal aortic aneurysm repair: written by the Standards of Practice Committee for the Society of Interventional Radiology and endorsed by the Cardiovascular and Interventional Radiological Society of Europe and the Canadian Interventional Radiology As , 2010, Journal of vascular and interventional radiology : JVIR.

[56]  P. Kreienberg,et al.  A Prospective Evaluation of the Impact of Balloon-Expandable Palmaz Stent Placement in Aortic Neck During EVAR , 2010 .

[57]  A. Freyrie,et al.  Ring-stents supported infrarenal aortic endograft fits well in abdominal aortic aneurysms with tortuous anatomy. , 2010, The Journal of cardiovascular surgery.

[58]  R. Ghotbi,et al.  New results with 100 Excluder cases. , 2010, Journal of Cardiovascular Surgery.

[59]  J. Brazier,et al.  Populating an economic model with health state utility values: moving toward better practice. , 2010, Value in health : the journal of the International Society for Pharmacoeconomics and Outcomes Research.

[60]  A. Karthikesalingam,et al.  Secondary interventions following endovascular aneurysm repair (EVAR) and the enduring value of graft surveillance. , 2010, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[61]  M M Thompson,et al.  Risk of reintervention after endovascular aortic aneurysm repair , 2010, The British journal of surgery.

[62]  A. Karthikesalingam,et al.  Duplex ultrasound and contrast-enhanced ultrasound versus computed tomography for the detection of endoleak after EVAR: systematic review and bivariate meta-analysis. , 2010, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[63]  F. Verzini,et al.  Endoleak after endovascular aortic repair: classification, diagnosis and management following endovascular thoracic and abdominal aortic repair. , 2010, The Journal of cardiovascular surgery.

[64]  S. Vallabhaneni,et al.  Adjunctive Iliac Stents Reduce the Risk of Stent-Graft Limb Occlusion following Endovascular Aneurysm Repair with the Zenith Stent-Graft , 2010, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[65]  K. Calligaro,et al.  From the Society for Clinical Vascular Surgery Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance : A cost analysis study and prospective comparison with computed tomography scan , 2022 .

[66]  T. Carrell,et al.  Long‐term surveillance with computed tomography after endovascular aneurysm repair may not be justified , 2009, The British journal of surgery.

[67]  Aravinda Nanjundappa,et al.  The correlation of aortic neck length to early and late outcomes in endovascular aneurysm repair patients. , 2009, Journal of vascular surgery.

[68]  Elliot L Chaikof,et al.  The care of patients with an abdominal aortic aneurysm: the Society for Vascular Surgery practice guidelines. , 2009, Journal of vascular surgery.

[69]  N. Cheshire,et al.  Update: Complications and management of infrarenal EVAR. , 2009, European journal of radiology.

[70]  B. Sonesson,et al.  Is there a benefit of frequent CT follow-up after EVAR? , 2009, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[71]  M. Makaroun,et al.  Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: a safe alternative for stable aneurysms. , 2009, Journal of vascular surgery.

[72]  A. Freyrie,et al.  The advantages of Anaconda endograft for AAA. , 2009, The Journal of cardiovascular surgery.

[73]  Maria Luigia Storto,et al.  Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair. , 2009, Journal of vascular surgery.

[74]  C. Bartolozzi,et al.  Ultrasonographic Surveillance with Selective CTA after Endovascular Repair of Abdominal Aortic Aneurysm , 2009, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[75]  R. Greenberg,et al.  From the Southern Association for Vascular Surgery Redefining postoperative surveillance after endovascular aneurysm repair : Recommendations based on 5-year follow-up in the US Zenith multicenter trial , 2008 .

[76]  J. Kaufman,et al.  Follow-up of endovascular aneurysm repair: plain radiography, ultrasound, CT/CT angiography, MR imaging/MR angiography, or what? , 2008, Journal of vascular and interventional radiology : JVIR.

[77]  S. Walsh,et al.  Renal Consequences of Endovascular Abdominal Aortic Aneurysm Repair , 2008, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[78]  C. Kyriakides,et al.  Surveillance of patients post-endovascular aneurysm repair , 2007, Postgraduate Medical Journal.

[79]  D. Brenner,et al.  Computed tomography--an increasing source of radiation exposure. , 2007, The New England journal of medicine.

[80]  J. T. Collins,et al.  Ultrasound surveillance of endovascular aneurysm repair: a safe modality versus computed tomography. , 2007, Annals of vascular surgery.

[81]  O. Rowiński,et al.  Late aneurysm rupture after endovascular abdominal aneurysm repair. , 2007, Interactive cardiovascular and thoracic surgery.

[82]  P. Desgranges,et al.  Limb graft occlusion following EVAR: clinical pattern, outcomes and predictive factors of occurrence. , 2007, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[83]  S. Stavropoulos,et al.  Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. , 2007, Radiology.

[84]  F. Speziale,et al.  Contrast ultrasound imaging: the best method to detect type II endoleak during endovascular aneurysm repair follow-up. , 2007, Interactive cardiovascular and thoracic surgery.

[85]  P. Harris,et al.  Secondary interventions after elective endovascular repair of degenerative thoracic aortic aneurysms: results of the European collaborators registry (EUROSTAR). , 2007, Journal of vascular and interventional radiology : JVIR.

[86]  David Moher,et al.  Development of AMSTAR: a measurement tool to assess the methodological quality of systematic reviews , 2007, BMC medical research methodology.

[87]  L. Bonomo,et al.  Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? , 2006, Radiology.

[88]  M. Macari,et al.  Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? , 2006, Radiology.

[89]  M. Bown,et al.  Duplex ultrasound scanning is reliable in the detection of endoleak following endovascular aneurysm repair. , 2006, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[90]  P. Dagnelie,et al.  Influence of Infrarenal Neck Length on Outcome of Endovascular Abdominal Aortic Aneurysm Repair , 2006, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[91]  B. Katzen,et al.  Complications of Endovascular Repair of Abdominal Aortic Aneurysms: A Review , 2006, CardioVascular and Interventional Radiology.

[92]  J. Buth,et al.  Secondary interventions following endovascular abdominal aortic aneurysm repair using current endografts. A EUROSTAR report. , 2006, Journal of vascular surgery.

[93]  Zhonghua Sun Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. , 2006, Journal of vascular and interventional radiology : JVIR.

[94]  P. Glasziou,et al.  The GATE frame: critical appraisal with pictures , 2006, Evidence-based nursing.

[95]  A. Lumsden,et al.  Contrast-enhanced Duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique. , 2006, Journal of vascular surgery.

[96]  R. Laheij,et al.  What Determines and Are the Consequences of Surveillance Intensity after Endovascular Abdominal Aortic Aneurysm Repair? , 2005, Annals of vascular surgery.

[97]  EVAR trial participants,et al.  Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial , 2005, The Lancet.

[98]  S. Thomas,et al.  Results from the prospective registry of endovascular treatment of abdominal aortic aneurysms (RETA): mid term results to five years. , 2005, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[99]  E. Choke,et al.  Color Duplex Ultrasonography is Insensitive for the Detection of Endoleak after Aortic Endografting: A Systematic Review , 2005, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[100]  C. Bartolozzi,et al.  Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. , 2004, Radiology.

[101]  J. Buth,et al.  The multicenter experience with a third-generation endovascular device for abdominal aortic aneurysm repair. A report from the EUROSTAR database. , 2004, The Journal of cardiovascular surgery.

[102]  P. Bachleda,et al.  Endovascular treatment of abdominal aortic aneurysms--6 years of experience with Ella stent-graft system. , 2004, European journal of radiology.

[103]  Andrew Briggs,et al.  Cost-effectiveness acceptability curves--facts, fallacies and frequently asked questions. , 2004, Health economics.

[104]  P. Harris,et al.  Diameter of abdominal aortic aneurysm and outcome of endovascular aneurysm repair: does size matter? A report from EUROSTAR. , 2004, Journal of vascular surgery.

[105]  F. Moll,et al.  AneuRx Stent-Graft Failure Four Years after TAA Exclusion , 2004 .

[106]  P. Harris,et al.  Is a type II endoleak after EVAR a harbinger of risk? Causes and outcome of open conversion and aneurysm rupture during follow-up. , 2004, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[107]  J. Semmens,et al.  Follow-up after Endovascular Aortic Aneurysm Repair: The Plain Radiograph Has an Essential Role in Surveillance , 2003 .

[108]  S. Geller,et al.  Imaging guidelines for abdominal aortic aneurysm repair with endovascular stent grafts. , 2003, Journal of vascular and interventional radiology : JVIR.

[109]  P. Harris,et al.  Endoleaks during follow-up after endovascular repair of abdominal aortic aneurysm. Are they all dangerous? , 2003, The Journal of cardiovascular surgery.

[110]  H. Rousseau,et al.  Midterm Outcomes of Thoracic Aortic Stent-Grafts: Complications and Imaging Techniques , 2003, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[111]  P. Bendick,et al.  Duplex Ultrasound Imaging with an Ultrasound Contrast Agent: The Economic Alternative to CT Angiography for Aortlc Sten tGraft Surveillance , 2003, Vascular and endovascular surgery.

[112]  Larry H Hollier,et al.  Predicting iliac limb occlusions after bifurcated aortic stent grafting: anatomic and device-related causes. , 2002, Journal of vascular surgery.

[113]  G. Rubin,et al.  Changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm. , 2002, Journal of vascular surgery.

[114]  F. Verzini,et al.  Does the presence of an iliac aneurysm affect outcome of endoluminal AAA repair? An analysis of 336 cases. , 2002, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[115]  G. Upchurch,et al.  Endovascular Abdominal Aortic Aneurysm Repair , 2002, Circulation.

[116]  Rodney A. White,et al.  Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. , 2002, Journal of vascular surgery.

[117]  S. Money,et al.  Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. , 2002, Journal of vascular surgery.

[118]  G. Meier,et al.  Endotension after endovascular aneurysm repair: the Ancure experience. , 2001, Journal of vascular surgery.

[119]  S. Rao Vallabhaneni,et al.  Internationale Fachliteratur , 2001, Gefässchirurgie.

[120]  A. Lumsden,et al.  Mid-term results after endovascular repair of the abdominal aortic aneurysm. , 2001, Journal of vascular surgery.

[121]  P L Harris,et al.  Need for secondary interventions after endovascular repair of abdominal aortic aneurysms. Intermediate‐term follow‐up results of a European collaborative registry (EUROSTAR) , 2000, The British journal of surgery.

[122]  G. Rubin,et al.  Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. , 2000, Journal of vascular surgery.

[123]  S. Dyer,et al.  Colour Doppler diagnosis of perigraft flow following endovascular repair of abdominal aortic aneurysm. , 2000, International angiology : a journal of the International Union of Angiology.

[124]  Pascal Desgranges,et al.  Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience , 2000 .

[125]  D. Raithel,et al.  Aortic Aneurysm Size and Graft Behavior after Endovascular Stent-Grafting: Clinical Experiences and Observations over 3 Years , 2000, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[126]  F. Verzini,et al.  Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair. , 2000, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[127]  M. Stewart,et al.  Late abdominal aortic aneurysm rupture after AneuRx repair: a report of three cases. , 2000, Journal of vascular surgery.

[128]  P. Harris,et al.  Realistic expectations for patients with stent-graft treatment of abdominal aortic aneurysms. Results of a European multicentre registry. , 1999, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[129]  H. Vet,et al.  The Delphi list: a criteria list for quality assessment of randomized clinical trials for conducting systematic reviews developed by Delphi consensus. , 1998, Journal of clinical epidemiology.

[130]  B. Herts,et al.  Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. , 1998, Journal of vascular surgery.

[131]  N. Black,et al.  The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions. , 1998, Journal of epidemiology and community health.

[132]  M J Al,et al.  Costs, effects and C/E-ratios alongside a clinical trial. , 1994, Health economics.

[133]  J. Parodi,et al.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms , 1991, Annals of vascular surgery.

[134]  M. Mcfarlane,et al.  The epidemiologic necropsy for abdominal aortic aneurysm. , 1991, JAMA.

[135]  P. Parfrey,et al.  Contrast material-induced renal failure in patients with diabetes mellitus, renal insufficiency, or both. A prospective controlled study. , 1989, The New England journal of medicine.

[136]  N. Volodos',et al.  [A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm]. , 1988, Grudnaia khirurgiia.

[137]  S. Wilson Methods for the economic evaluation of health care programmes , 1987 .

[138]  S. Golder,et al.  Good Practice Guidelines for Decision-Analytic Modelling in Health Technology Assessment , 2012, PharmacoEconomics.

[139]  M. Sculpher,et al.  The UK EndoVascular Aneurysm Repair (EVAR) trials: randomised trials of EVAR versus standard therapy. , 2012, Health technology assessment.

[140]  S. Haulon,et al.  Management of abdominal aortic aneurysms clinical practice guidelines of the European society for vascular surgery. , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[141]  J. Ricco,et al.  Each Generation will Reap what the Former Generation has Sown , 2011 .

[142]  J. Kline,et al.  Incidence of contrast-induced nephropathy after contrast-enhanced computed tomography in the outpatient setting. , 2010, Clinical journal of the American Society of Nephrology : CJASN.

[143]  D. Moher,et al.  Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. , 2010, International journal of surgery.

[144]  M. Reiser,et al.  Imaging of endoleaks after endovascular aneurysm repair (EVAR) with contrast-enhanced ultrasound (CEUS). A pictorial comparison with CTA. , 2009, Clinical hemorheology and microcirculation.

[145]  P. Lin,et al.  Aneurysm rupture after EVAR: can the ultimate failure be predicted? , 2009, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[146]  D. Moore,et al.  Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography. , 2009, Journal of vascular surgery.

[147]  Akers,et al.  Systematic Reviews [ressource électronique]. CRD's guidance for undertaking reviews in health care , 2009 .

[148]  M. Makaroun,et al.  What is the clinical utility of a 6-month computed tomography in the follow-up of endovascular aneurysm repair patients? , 2008, Journal of vascular surgery.

[149]  R. Laheij,et al.  Long-term results of endovascular abdominal aortic aneurysm treatment with the first generation of commercially available stent grafts. , 2007, Archives of surgery.

[150]  C. Zarins Lifeline registry of endovascular aneurysm repair: long-term primary outcome measures. , 2005, Journal of vascular surgery.

[151]  Lifeline Registry of Endovascular Aneurysm Repair: Registry data report. , 2002, Journal of vascular surgery.

[152]  P. Gaines,et al.  Short-term (30-day) outcome of endovascular treatment of abdominal aortic aneurism: results from the prospective Registry of Endovascular Treatment of Abdominal Aortic Aneurism (RETA). , 2001, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[153]  D. Bergqvist,et al.  Increasing prevalence of abdominal aortic aneurysms. A necropsy study. , 1992, The European journal of surgery = Acta chirurgica.