Fuzzy Logic Controller Based Shunt Active Filter with Different MFs for Current Harmonics Elimination

One of the major power quality concerns in modern times is the problem of current harmonics. The current harmonics is caused due to the increase in non-linear loads which is largely dominated by power electronics devices. The Shunt active filtering is one of the best solutions for mitigating current harmonics. This paper describes a fuzzy logic controller based (FLC) based three Phase Shunt active Filter to achieve low current harmonic distortion (THD) and Reactive power compensation. The performance of fuzzy logic controller is analysed under both balanced sinusoidal and unbalanced sinusoidal source condition. The above controller serves the purpose of maintaining DC Capacitor Voltage constant. The proposed shunt active filter uses hysteresis current controller for current control of IGBT based PWM inverter. The simulation results of model in Simulink MATLAB reveals satisfying results. Keywords—Shunt active filter, Current harmonics, Fuzzy logic controller, Hysteresis current controller.

[1]  Thomas A. Runkler,et al.  Selection of appropriate defuzzification methods using application specific properties , 1997, IEEE Trans. Fuzzy Syst..

[2]  E.R. Cadaval,et al.  Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems , 2007, IEEE Transactions on Power Electronics.

[3]  Anup Kumar Panda,et al.  Real-time implementation of PI and fuzzy logic controllers based shunt active filter control strategies for power quality improvement , 2012 .

[4]  Hirofumi Akagi,et al.  New trends in active filters for power conditioning , 1996 .

[5]  P. Kirawanich,et al.  Fuzzy logic control of an active power line conditioner , 2004, IEEE Transactions on Power Electronics.

[6]  P. Kirawanich,et al.  Fuzzy logic control of an active power line conditioner , 2002, The 2002 45th Midwest Symposium on Circuits and Systems, 2002. MWSCAS-2002..

[7]  Fumio Harashima,et al.  A Closed-Loop Control System for the Reduction of Reactive Power Required by Electronic Converters , 1976, IEEE Transactions on Industrial Electronics and Control Instrumentation.

[8]  Anup Kumar Panda,et al.  Performance analysis and real‐time implementation of shunt active filter Id‐Iq control strategy with type‐1 and type‐2 FLC triangular M.F , 2014 .

[9]  Myung Jin Chung,et al.  Robustness of fuzzy logic control for an uncertain dynamic system , 1998, IEEE Trans. Fuzzy Syst..

[10]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[11]  Chi-Seng Lam,et al.  Active Power Filters , 2016 .

[12]  D. J. Adams,et al.  Harmonic and reactive power compensation based on the generalized instantaneous reactive power theory for three-phase four-wire systems , 1998 .