An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device

This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.

[1]  Ming Li,et al.  Pneumatic Actuated Robotic Assistant System for Aortic Valve Replacement Under MRI Guidance , 2011, IEEE Transactions on Biomedical Engineering.

[2]  U-Xuan Tan,et al.  Design and Control of a 1-DOF MRI-Compatible Pneumatically Actuated Robot With Long Transmission Lines , 2011, IEEE/ASME Transactions on Mechatronics.

[3]  Zion Tsz Ho Tse,et al.  Haptic Needle Unit for MR-Guided Biopsy and Its Control , 2012, IEEE/ASME Transactions on Mechatronics.

[4]  M. C. Cavusoglu,et al.  In Touch with Robotics: Neurosurgery for the Future , 2005, Neurosurgery.

[5]  Kemal Tuncali,et al.  3T MR‐guided in‐bore transperineal prostate biopsy: A comparison of robotic and manual needle‐guidance templates , 2015, Journal of magnetic resonance imaging : JMRI.

[6]  Robert J. Webster,et al.  Design and Control of an Magnetic Resonance Compatible Precision Pneumatic Active Cannula Robot , 2014 .

[7]  Aaron Becker,et al.  Achieving Commutation Control of an MRI-Powered Robot Actuator , 2015, IEEE Transactions on Robotics.

[8]  T. Podder,et al.  Robotic system for prostate brachytherapy , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[9]  Weijian Shang,et al.  Teleoperation of MRI-Compatible Robots with Hybrid Actuation and Haptic Feedback , 2015 .

[10]  Bo Yang,et al.  Design, development, and evaluation of a master–slave surgical system for breast biopsy under continuous MRI , 2014, Int. J. Robotics Res..

[11]  Aaron Fenster,et al.  Mechatronic system for in‐bore MRI‐guided insertion of needles to the prostate: An in vivo needle guidance accuracy study , 2015, Journal of magnetic resonance imaging : JMRI.

[12]  Jaydev P. Desai,et al.  Towards a teleoperated needle driver robot with haptic feedback for RFA of breast tumors under continuous MRI , 2009, Medical Image Anal..

[13]  Ian Young,et al.  The Feasibility of MR-Image Guided Prostate Biopsy Using Piezoceramic Motors Inside or Near to the Magnet Isocentre , 2006, MICCAI.

[14]  Nobuhiko Hata,et al.  Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy , 2015, IEEE/ASME Transactions on Mechatronics.

[15]  Paolo Dario,et al.  A Miniaturized Mechatronic System Inspired by Plant Roots for Soil Exploration , 2011, IEEE/ASME Transactions on Mechatronics.

[16]  Jaydev P. Desai,et al.  Toward a Meso-Scale SMA-Actuated MRI-Compatible Neurosurgical Robot , 2012, IEEE Transactions on Robotics.

[17]  Gang Li,et al.  In‐bore prostate transperineal interventions with an MRI‐guided parallel manipulator: system development and preliminary evaluation , 2016, The international journal of medical robotics + computer assisted surgery : MRCAS.

[18]  K Chinzei,et al.  Towards MRI guided surgical manipulator. , 2001, Medical science monitor : international medical journal of experimental and clinical research.

[19]  G. Fichtinger,et al.  Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention , 2013, IEEE/ASME Transactions on Mechatronics.

[20]  Gang Li,et al.  Teleoperation system with hybrid pneumatic-piezoelectric actuation for MRI-guided needle insertion with haptic feedback , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[21]  Hao Su,et al.  Real-time MRI-guided needle placement robot with integrated fiber optic force sensing , 2011, 2011 IEEE International Conference on Robotics and Automation.

[22]  Tom W J Scheenen,et al.  Feasibility of a pneumatically actuated MR-compatible robot for transrectal prostate biopsy guidance. , 2011, Radiology.

[23]  Lucas J. van Vliet,et al.  Expiration-Phase Template-Based Motion Correction of Free-Breathing Abdominal Dynamic Contrast Enhanced MRI , 2015, IEEE Transactions on Biomedical Engineering.

[24]  T. K. Gangopadhyay,et al.  Prospects for Fibre Bragg Gratings and Fabry-Perot Interferometers in fibre-optic vibration sensing , 2004 .

[25]  Gang Li,et al.  Closed-loop asymmetric-tip needle steering under continuous intraoperative MRI guidance , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[26]  Hao Su,et al.  Robotic System for MRI-Guided Stereotactic Neurosurgery , 2015, IEEE Transactions on Biomedical Engineering.

[27]  John Strang,et al.  Robotic system for prostate brachytherapy. , 2007 .