A Modified Three-Phase Four-Wire UPQC Topology With Reduced DC-Link Voltage Rating

The unified power quality conditioner (UPQC) is a custom power device, which mitigates voltage and current-related PQ issues in the power distribution systems. In this paper, a UPQC topology for applications with non-stiff source is proposed. The proposed topology enables UPQC to have a reduced dc-link voltage without compromising its compensation capability. This proposed topology also helps to match the dc-link voltage requirement of the shunt and series active filters of the UPQC. The topology uses a capacitor in series with the interfacing inductor of the shunt active filter, and the system neutral is connected to the negative terminal of the dc-link voltage to avoid the requirement of the fourth leg in the voltage source inverter (VSI) of the shunt active filter. The average switching frequency of the switches in the VSI also reduces, consequently the switching losses in the inverters reduce. Detailed design aspects of the series capacitor and VSI parameters have been discussed in the paper. A simulation study of the proposed topology has been carried out using PSCAD simulator, and the results are presented. Experimental studies are carried out on three-phase UPQC prototype to verify the proposed topology.

[1]  M. Brenna,et al.  A New Proposal for Power Quality and Custom Power Improvement: OPEN UPQC , 2009, IEEE Transactions on Power Delivery.

[2]  J. Fernando A. da Silva,et al.  Multilevel Optimal Predictive Dynamic Voltage Restorer , 2010, IEEE Transactions on Industrial Electronics.

[3]  Patricia Liliana Arnera,et al.  Hybrid Active Filter for Reactive and Harmonics Compensation in a Distribution Network , 2009, IEEE Transactions on Industrial Electronics.

[4]  Robert Stala,et al.  Application of Balancing Circuit for DC-Link Voltages Balance in a Single-Phase Diode-Clamped Inverter With Two Three-Level Legs , 2011, IEEE Transactions on Industrial Electronics.

[5]  Hurng-Liahng Jou,et al.  Novel power converter topology for threephase four-wire hybrid power filter , 2008 .

[6]  Arindam Ghosh,et al.  Multiband Hysteresis Modulation and Switching Characterization for Sliding-Mode-Controlled Cascaded Multilevel Inverter , 2010, IEEE Transactions on Industrial Electronics.

[7]  Frede Blaabjerg,et al.  A Robust Control Scheme for Medium-Voltage-Level DVR Implementation , 2007, IEEE Transactions on Industrial Electronics.

[8]  F. Blaabjerg,et al.  Investigation and improvement of transient response of DVR at medium voltage level , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[9]  A. Ghosh,et al.  Control Strategies for Load Compensation Using Instantaneous Symmetrical Component Theory Under Different Supply Voltages , 2008, IEEE Transactions on Power Delivery.

[10]  Boon Teck Ooi,et al.  A Three-Phase Controlled-Current PWM Converter with Leading Power Factor , 1987, IEEE Transactions on Industry Applications.

[11]  Bhim Singh,et al.  A Comparison of Control Algorithms for DSTATCOM , 2009, IEEE Transactions on Industrial Electronics.

[12]  Frede Blaabjerg,et al.  Control and testing of a dynamic voltage restorer (DVR) at medium voltage level , 2004 .

[13]  B. Singh,et al.  A T-Connected Transformer and Three-leg VSC Based DSTATCOM for Power Quality Improvement , 2008, IEEE Transactions on Power Electronics.

[14]  Mahesh Kumar Mishra,et al.  DC Capacitor Voltage Equalization in Neutral Clamped Inverters for DSTATCOM Application , 2010, IEEE Transactions on Industrial Electronics.

[15]  Kamalakanta Mahapatra,et al.  Power Loss Estimation for PWM and Soft-switching Inverter using RDCLI , 2010 .

[16]  Donald W. Novotny,et al.  Current Control of VSI-PWM Inverters , 1985, IEEE Transactions on Industry Applications.

[17]  D. Mahinda Vilathgamuwa,et al.  A Novel Technique to Compensate Voltage Sags in Multiline Distribution System—The Interline Dynamic Voltage Restorer , 2006, IEEE Transactions on Industrial Electronics.

[18]  Hirofumi Akagi,et al.  A Transformerless Hybrid Active Filter Using a Three-Level Pulsewidth Modulation (PWM) Converter for a Medium-Voltage Motor Drive , 2010, IEEE Transactions on Power Electronics.

[19]  Bhim Singh,et al.  A comparative analysis of three-phase four-wire UPQC topologies , 2010, 2010 Joint International Conference on Power Electronics, Drives and Energy Systems & 2010 Power India.

[20]  Ambrish Chandra,et al.  A Novel Structure for Three-Phase Four-Wire Distribution System Utilizing Unified Power Quality Conditioner (UPQC) , 2006 .

[21]  Arindam Ghosh,et al.  Switching Characterization of Cascaded Multilevel-Inverter-Controlled Systems , 2008, IEEE Transactions on Industrial Electronics.

[22]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[23]  A. Chandra,et al.  A New Control Philosophy for a Unified Power Quality Conditioner (UPQC) to Coordinate Load-Reactive Power Demand Between Shunt and Series Inverters , 2008, IEEE Transactions on Power Delivery.

[24]  M.K. Mishra,et al.  Design of passive filter components for switching band controlled DVR , 2008, TENCON 2008 - 2008 IEEE Region 10 Conference.

[25]  Kamal Al-Haddad,et al.  Experimental Design of a Nonlinear Control Technique for Three-Phase Shunt Active Power Filter , 2010, IEEE Transactions on Industrial Electronics.

[26]  Pankaj Dahire,et al.  Simulation of D-Statcom and Dvr in Power Systems , 2013 .

[27]  María Isabel Milanés-Montero,et al.  Hybrid Multiconverter Conditioner Topology for High-Power Applications , 2011, IEEE Transactions on Industrial Electronics.

[28]  Li Xun,et al.  A direct control strategy for UPQC in three-phase four-wire system , 2006, 2006 CES/IEEE 5th International Power Electronics and Motion Control Conference.

[29]  M.K. Mishra,et al.  Design and analysis of voltage source inverter for active compensators to compensate unbalanced and non-linear loads , 2007, 2007 International Power Engineering Conference (IPEC 2007).

[30]  Ping Lam So,et al.  Model-Based $\hbox{H}_{\infty}$ Control of a Unified Power Quality Conditioner , 2009, IEEE Transactions on Industrial Electronics.

[31]  Arindam Ghosh,et al.  Characteristic Analysis for Multisampled Digital Implementation of Fixed-Switching-Frequency Closed-Loop Modulation of Voltage-Source Inverter , 2009, IEEE Transactions on Industrial Electronics.

[32]  Engin Özdemir,et al.  Synchronous-Reference-Frame-Based Control Method for UPQC Under Unbalanced and Distorted Load Conditions , 2011, IEEE Transactions on Industrial Electronics.

[33]  Li Xun,et al.  A New Control Strategy of UPQC in Three-phase Four-wire System , 2007, 2007 IEEE Power Electronics Specialists Conference.

[34]  B. Singh,et al.  Load Compensation for Diesel Generator Based Isolated Generation System Employing DSTATCOM , 2006, 2006 International Conference on Power Electronic, Drives and Energy Systems.

[35]  Mehrdad Kazerani,et al.  Modeling, control and implementation of three-phase PWM converters , 2003 .

[36]  Mahesh K. Mishra,et al.  DSTATCOM topologies for three-phase high power applications , 2010 .