Strength and stiffness of post-heated columns repaired with ferrocement and fibre reinforced polymer jackets

Abstract This paper presents the results of an experimental study carried out to compare the effectiveness of ferrocement and fibre reinforced polymers (FRPs) jackets for the repair of post-heated square and circular reinforced concrete columns. The suite of test specimens comprised (a) non-heated and non-repaired; (b) post-heated and non-repaired and (c) post-heated and repaired, columns. Glass fibre reinforced polymer (GFRP), carbon fibre reinforced polymer (CFRP) and ferrocement jackets were used to repair the heated columns. All the columns were tested under axial compression. The test results covering the axial compressive strength, stiffness (secant stiffness), ductility, deformation and energy dissipation for the non-heated and non-repaired, and post-heated and non-repaired columns, were explored and compared with those of the post-heated columns repaired with FRP and ferrocement jackets. The test results showed that the FRP jackets increased the compressive strength, ductility, deformation ability and energy dissipation capacity of post-heated columns but did not increase the stiffness. However, the ferrocement jackets enhanced both the strength and stiffness of the post-heated columns. It is concluded that a possible combination of ferrocement and FRP jackets is the optimum solution to restore the required strength, stiffness and ductility following structural damage from a fire.

[1]  Abdullah,et al.  An investigation into the behavior and strength of reinforced concrete columns strengthened with ferrocement jackets , 2003 .

[2]  Mohsen A. Issa,et al.  Experimental and Parametric Study of Circular Short Columns Confined with CFRP Composites , 2009 .

[3]  Paul Nedwell,et al.  Axial capacity of post-heated square columns wrapped with FRP composites , 2011 .

[4]  Kristian Dahl Hertz,et al.  Concrete strength for fire safety design , 2005 .

[5]  Habib Abdelhak Mesbah,et al.  Behaviour of square concrete column confined with GFRP composite warp , 2008 .

[6]  Colin Bailey,et al.  Cross sectional shape effects on the performance of post-heated reinforced concrete columns wrapped with FRP composites , 2011 .

[7]  Tamer El Maaddawy,et al.  Post-repair performance of eccentrically loaded RC columns wrapped with CFRP composites , 2008 .

[8]  Muhammad N. S. Hadi,et al.  Behaviour of eccentric loading of FRP confined fibre steel reinforced concrete columns , 2009 .

[9]  Zhong Tao,et al.  Compressive behaviour of CFRP-confined rectangular concrete columns , 2008 .

[10]  Z. Tao,et al.  Compressive and flexural behaviour of CFRP-repaired concrete-filled steel tubes after exposure to fire , 2007 .

[11]  Behaviour of ferrocement confined reinforced concrete (FCRC) under axial compression , 1998 .

[12]  Ezzat H. Fahmy,et al.  Repairing reinforced concrete columns using ferrocement laminates , 1999 .

[13]  B. Doran,et al.  Compressive behavior of large-scale square reinforced concrete columns confined with carbon fiber reinforced polymer jackets , 2010 .

[14]  Eric Walter Marchant A complete guide to fire and buildings , 1972 .

[15]  P. Rathish Kumar,et al.  Ferrocement confinement of plain and reinforced concrete , 2004 .

[16]  Fabio Matta,et al.  Behavior of full-scale glass fiber-reinforced polymer reinforced concrete columns under axial load , 2010 .

[17]  W. N. Al-Rifaie,et al.  Strength of ferrocement-brick composite columns , 2000 .

[18]  Colin Bailey,et al.  Repair of fire damaged circular reinforced concrete columns with FRP composites , 2011 .

[19]  R. Vaidyanathan,et al.  Behaviour of reinforced concrete rectangular columns strengthened using GFRP , 2007 .

[20]  P Paramasivam,et al.  Ferrocement Short Columns Under Axial and Eccentric Compression , 1990 .

[21]  Surendra P. Shah,et al.  GUIDE FOR THE DESIGN, CONSTRUCTION, AND REPAIR OF FERROCEMENT. , 1988 .

[22]  Z. Tao,et al.  Behaviour of fire-exposed concrete-filled steel tubular beam columns repaired with CFRP wraps , 2007 .

[23]  Abdullah,et al.  SHEAR STRENGTHENING OF REINFORCED CONCRETE COLUMNS USING FERROCEMENT JACKET , 2001 .

[24]  Jeremy Ingham,et al.  Forensic engineering of fire-damaged structures , 2009 .

[25]  Jack A. Gilbert,et al.  Behavior of Large-Scale Rectangular Columns Confined with FRP Composites , 2010 .

[26]  John Purkiss,et al.  Fire Safety Engineering Design of Structures , 1996 .

[27]  B. Kondraivendhan,et al.  Effect of ferrocement confinement on behavior of concrete , 2009 .

[28]  M. Shahria Alam,et al.  Experimental investigation of the use of ferrocement laminates for repairing masonry in filled RC frames , 2007 .