Optimization of PET–MR registrations for nonhuman primates using mutual information measures: A Multi-Transform Method (MTM)

An important step in PET brain kinetic analysis is the registration of functional data to an anatomical MR image. Typically, PET-MR registrations in nonhuman primate neuroreceptor studies used PET images acquired early post-injection, (e.g., 0-10 min) to closely resemble the subject's MR image. However, a substantial fraction of these registrations (~25%) fail due to the differences in kinetics and distribution for various radiotracer studies and conditions (e.g., blocking studies). The Multi-Transform Method (MTM) was developed to improve the success of registrations between PET and MR images. Two algorithms were evaluated, MTM-I and MTM-II. The approach involves creating multiple transformations by registering PET images of different time intervals, from a dynamic study, to a single reference (i.e., MR image) (MTM-I) or to multiple reference images (i.e., MR and PET images pre-registered to the MR) (MTM-II). Normalized mutual information was used to compute similarity between the transformed PET images and the reference image(s) to choose the optimal transformation. This final transformation is used to map the dynamic dataset into the animal's anatomical MR space, required for kinetic analysis. The chosen transforms from MTM-I and MTM-II were evaluated using visual rating scores to assess the quality of spatial alignment between the resliced PET and reference images. One hundred twenty PET datasets involving eleven different tracers from 3 different scanners were used to evaluate the MTM algorithms. Studies were performed with baboons and rhesus monkeys on the HR+, HRRT, and Focus-220. Successful transformations increased from 77.5%, 85.8%, to 96.7% using the 0-10 min method, MTM-I, and MTM-II, respectively, based on visual rating scores. The Multi-Transform Methods proved to be a robust technique for PET-MR registrations for a wide range of PET studies.

[1]  Kevin J Black,et al.  Atlas template images for nonhuman primate neuroimaging: baboon and macaque. , 2004, Methods in enzymology.

[2]  J. Cheverud,et al.  Heritability of brain size and surface features in rhesus macaques (Macaca mulatta). , 1990, Journal of Heredity.

[3]  J. Mazziotta,et al.  MRI‐PET Registration with Automated Algorithm , 1993, Journal of computer assisted tomography.

[4]  Nasser Kehtarnavaz,et al.  Brain Functional Localization: A Survey of Image Registration Techniques , 2007, IEEE Transactions on Medical Imaging.

[5]  D L Hill,et al.  Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. , 1997, Medical physics.

[6]  R. Kahn,et al.  Quantitative genetic modeling of variation in human brain morphology. , 2001, Cerebral cortex.

[7]  Ralph Myers,et al.  The application of PET-MR image registration in the brain. , 2002, The British journal of radiology.

[8]  Sterling C. Johnson,et al.  A population-average MRI-based atlas collection of the rhesus macaque , 2009, NeuroImage.

[9]  Yu-Shin Ding,et al.  [11C]GR103545: novel one-pot radiosynthesis with high specific activity. , 2011, Nuclear medicine and biology.

[10]  Richard E Carson,et al.  High-resolution imaging of brain 5-HT 1B receptors in the rhesus monkey using [11C]P943. , 2010, Nuclear medicine and biology.

[11]  Roger N. Gunn,et al.  A pharmacokinetic PET study of NK1 receptor occupancy , 2012, European Journal of Nuclear Medicine and Molecular Imaging.

[12]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[13]  Karl J. Friston,et al.  MRI and PET Coregistration—A Cross Validation of Statistical Parametric Mapping and Automated Image Registration , 1997, NeuroImage.

[14]  Jeih-San Liow,et al.  Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[15]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[16]  A. Brownell,et al.  Synthesis and preliminary biological evaluation of 3‐[18F]fluoro‐5‐(2‐pyridinylethynyl)benzonitrile as a PET radiotracer for imaging metabotropic glutamate receptor subtype 5 , 2007, Synapse.

[17]  Richard E. Carson,et al.  Evaluation of [11C]MRB for assessment of occupancy of norepinephrine transporters: Studies with atomoxetine in non-human primates , 2011, NeuroImage.

[18]  Ronald Boellaard,et al.  HRRT Versus HR+ Human Brain PET Studies: An Interscanner Test–Retest Study , 2009, Journal of Nuclear Medicine.

[19]  Ariel Graff-Guerrero,et al.  Brain region binding of the D2/3 agonist [11C]‐(+)‐PHNO and the D2/3 antagonist [11C]raclopride in healthy humans , 2008, Human brain mapping.

[20]  Dean F. Wong,et al.  Quantification of cerebral cannabinoid receptors subtype 1 (CB1) in healthy subjects and schizophrenia by the novel PET radioligand [11C]OMAR , 2010, NeuroImage.

[21]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[22]  Sylvain Houle,et al.  Radiosynthesis and initial evaluation of [18F]-FEPPA for PET imaging of peripheral benzodiazepine receptors. , 2008, Nuclear medicine and biology.

[23]  Wencke Lehnert,et al.  Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner , 2006, Physics in medicine and biology.

[24]  Guy Marchal,et al.  Automated multi-moda lity image registration based on information theory , 1995 .

[25]  Bristol-Myers Squibb,et al.  Short Communication Assessing the Sensitivity of ( 11 C)P943, a Novel 5-HT IB Radioligand, to Endogenous Serotonin Release , 2011 .

[26]  Guy Marchal,et al.  Automated multi-modality image registration based on information theory , 1995 .

[27]  Richard E Carson,et al.  Assessing the sensitivity of [11C]p943, a novel 5‐HTIB radioligand, to endogenous serotonin release , 2011, Synapse.

[28]  Christos Davatzikos,et al.  Accuracy and Sensitivity of Detection of Activation Foci in the Brain via Statistical Parametric Mapping: A Study Using a PET Simulator , 2001, NeuroImage.

[29]  Hiroto Kuwabara,et al.  Naloxone-induced cortisol predicts mu opioid receptor binding potential in specific brain regions of healthy subjects , 2011, Psychoneuroendocrinology.

[30]  Marc Laruelle,et al.  A new positron emission tomography imaging agent for the serotonin transporter: synthesis, pharmacological characterization, and kinetic analysis of [11C]2-[2-(dimethylaminomethyl)phenylthio]-5-fluoromethylphenylamine ([11C]AFM). , 2004, Nuclear medicine and biology.

[31]  Balraj Naren,et al.  Medical Image Registration , 2022 .

[32]  Bostjan Likar,et al.  A protocol for evaluation of similarity measures for rigid registration , 2006, IEEE Transactions on Medical Imaging.