Percutaneous punctures with MR imaging guidance: comparison between MR imaging-enhanced fluoroscopic guidance and real-time MR Imaging guidance.

PURPOSE To evaluate and compare the technical accuracy and feasibility of magnetic resonance (MR) imaging-enhanced fluoroscopic guidance and real-time MR imaging guidance for percutaneous puncture procedures in phantoms and animals. MATERIALS AND METHODS The experimental protocol was approved by the institutional animal care and use committee. Punctures were performed in phantoms, aiming for markers (20 each for MR imaging-enhanced fluoroscopic guidance and real-time MR imaging guidance), and pigs, aiming for anatomic landmarks (10 for MR imaging-enhanced fluoroscopic guidance and five for MR imaging guidance). To guide the punctures, T1-weighted three-dimensional (3D) MR images of the phantom or pig were acquired. Additional axial and coronal T2-weighted images were used to visualize the anatomy in the animals. For MR imaging-enhanced fluoroscopic guidance, phantoms and pigs were transferred to the fluoroscopic system after initial MR imaging and C-arm computed tomography (CT) was performed. C-arm CT and MR imaging data sets were coregistered. Prototype navigation software was used to plan a puncture path with use of MR images and to superimpose it on fluoroscopic images. For real-time MR imaging, an interventional MR imaging prototype for interactive real-time section position navigation was used. Punctures were performed within the magnet bore. After completion, 3D MR imaging was performed to evaluate the accuracy of insertions. Puncture durations were compared by using the log-rank test. The Mann-Whitney U test was applied to compare the spatial errors. RESULTS In phantoms, the mean total error was 8.6 mm ± 2.8 with MR imaging-enhanced fluoroscopic guidance and 4.0 mm ± 1.2 with real-time MR imaging guidance (P < .001). The mean puncture time was 2 minutes 10 seconds ± 44 seconds with MR imaging-enhanced fluoroscopic guidance and 37 seconds ± 14 with real-time MR imaging guidance (P < .001). In the animal study, a tolerable distance (<1 cm) between target and needle tip was observed for both MR imaging-enhanced fluoroscopic guidance and real-time MR imaging guidance. The mean total error was 7.7 mm ± 2.4 with MR imaging-enhanced fluoroscopic guidance and 7.9 mm ± 4.9 with real-time MR imaging guidance (P = .77). The mean puncture time was 5 minutes 43 seconds ± 2 minutes 7 seconds with MR imaging-enhanced fluoroscopic guidance and 5 minutes 14 seconds ± 2 minutes 25 seconds with real-time MR imaging guidance (P = .68). CONCLUSION Both MR imaging-enhanced fluoroscopic guidance and real-time MR imaging guidance demonstrated reasonable and similar accuracy in guiding needle placement to selected targets in phantoms and animals.

[1]  Philippe L. Pereira,et al.  Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time , 2012, European Radiology.

[2]  J. Krücker,et al.  Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy. , 2007, Journal of vascular and interventional radiology : JVIR.

[3]  Robert Trampel,et al.  Navigation concepts for MR image‐guided interventions , 2008, Journal of magnetic resonance imaging : JMRI.

[4]  C Czerny,et al.  [Robot-assisted biopsies in a high-field MRI system - first clinical results]. , 2012, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[5]  Frank Sauer,et al.  An augmented reality system for MR image-guided needle biopsy: initial results in a swine model. , 2006, Radiology.

[6]  Martin Hoheisel,et al.  Electromagnetic field-based navigation for percutaneous punctures on C-arm CT: experimental evaluation and clinical application , 2008, European Radiology.

[7]  Martin G. Mack,et al.  Hybrid MR interventional imaging system: combined MR and angiography suites with single interactive table. Feasibility study in vascular liver tumor procedures , 2002, European Radiology.

[8]  T Kapapa,et al.  Image guided aneurysm surgery in a Brainsuite® ioMRI Miyabi 1.5 T environment. , 2011, Acta neurochirurgica. Supplement.

[9]  M. F. Reiser,et al.  Evaluation eines elektromagnetischen virtuellen Zielsystems (CT-Guide) für die Durchführung von CT-Interventionen , 2001 .

[10]  Bart Carelsen,et al.  Cone-beam computed tomography fusion and navigation for real-time positron emission tomography-guided biopsies and ablations: a feasibility study. , 2012, Journal of vascular and interventional radiology : JVIR.

[11]  M. Mack,et al.  Roboterunterstützte Punktion in einem Hochfeld-Kernspintomografen – erste klinische Ergebnisse , 2012 .

[12]  C. Ewertsen Image fusion between ultrasonography and CT, MRI or PET/CT for image guidance and intervention - a theoretical and clinical study. , 2010, Danish medical bulletin.

[13]  Alastair J. Martin,et al.  Carotid stent delivery in an XMR suite: immediate assessment of the physiologic impact of extracranial revascularization. , 2005, AJNR. American journal of neuroradiology.

[14]  P. Flandroy,et al.  A combined CT and angiography suite with a pivoting table. , 1996, Radiology.

[15]  M Reiser,et al.  [Evaluation of an electromagnetic virtual target system (CT-guide) for CT-guided interventions]. , 2001, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.