Influence of optical aberrations on laser-induced plasma formation in water and their consequences for intraocular photodisruption

The influence of spherical aberrations on laser-induced plasma formation in water by 6-ns Nd:YAG laser pulses was investigated for focusing angles that are used in intraocular microsurgery. Waveform distortions of 5.5λ and 18.5λ between the optical axis and the 1/e2 irradiance values of the laser beam were introduced by replacement of laser achromats in the delivery system by planoconvex lenses. Aberrations of 18.5λ increased the energy threshold for plasma formation by a factor of 8.5 compared with the optimized system. The actual irradiance threshold for optical breakdown was determined from the threshold energy in the optimized system and the spot size measured with a knife-edge technique. For aberrations of 18.5λ the irradiance threshold was 48 times larger than the actual threshold when it was calculated by use of the diffraction-limited spot size but was 35 times smaller when it was calculated by use of the measured spot size. The latter discrepancy is probably due to hot spots in the focal region of the aberrated laser beam. Hence the determination of the optical-breakdown threshold in the presence of aberrations leads to highly erroneous results. In the presence of aberrations the plasmas are as much as 3 times longer and the transmitted energy is 17–20 times higher than without aberrations. Aberrations can thus strongly compromise the precision and the safety of intraocular microsurgery. They can further account for a major part of the differences in the breakdown-threshold and the plasma-transmission values reported in previous investigations.

[1]  U. Parlitz,et al.  Energy balance of optical breakdown in water at nanosecond to femtosecond time scales , 1999 .

[2]  Thomas F. Deutsch,et al.  Preferential ablation of calcified arterial plaque with laser-induced plasmas , 1987 .

[3]  P Artal,et al.  Contributions of the cornea and the lens to the aberrations of the human eye. , 1998, Optics letters.

[4]  C. Puliafito,et al.  Plasma shielding by Q-switched and mode-locked Nd-YAG lasers. , 1983, Ophthalmology.

[5]  Werner Lauterborn,et al.  Acoustic transient generation by laser‐produced cavitation bubbles near solid boundaries , 1988 .

[6]  F. Campbell,et al.  Optical quality of the human eye , 1966, The Journal of physiology.

[7]  J. H. Bechtel,et al.  Dielectric-breakdown threshold and nonlinear-refractive-index measurements with picosecond laser pulses , 1975 .

[8]  A Vogel,et al.  Cavitation bubble dynamics and acoustic transient generation in ocular surgery with pulsed neodymium: YAG lasers. , 1986, Ophthalmology.

[9]  Junzhong Liang,et al.  Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[10]  L. Rayleigh VIII. On the pressure developed in a liquid during the collapse of a spherical cavity , 1917 .

[11]  C. Ireland,et al.  Aberration effects in the interaction of focused laser beams with matter , 1974 .

[12]  D. Hammer,et al.  A first-order model for computation of laser-induced breakdown thresholds in ocular and aqueous media. II. Comparison to experiment , 1995 .

[13]  C. G. Morgan Laser-induced breakdown of gases , 1975 .

[14]  Anthony E. Siegman,et al.  Choice of clip levels for beam width measurements using knife-edge techniques , 1991 .

[15]  R Birngruber,et al.  Mechanisms of intraocular photodisruption with picosecond and nanosecond laser pulses , 1994, Lasers in surgery and medicine.

[16]  A. Vogel,et al.  Nonlinear absorption: intraocular microsurgery and laser lithotripsy. , 1997, Physics in medicine and biology.

[17]  W. M. Rosenblum,et al.  III Objective and Subjective Spherical Aberration Measurements of the Human Eye , 1976 .

[18]  R. D. Jones,et al.  Laser-produced plasmas in medicine , 1991 .

[19]  U. Parlitz,et al.  Shock wave emission and cavitation bubble generation by picosecond and nanosecond optical breakdown in water , 1996 .

[20]  A. Vogel,et al.  Plasma formation in water by picosecond and nanosecond Nd:YAG laser pulses. II. Transmission, scattering, and reflection , 1996 .

[21]  Gary D. Noojin,et al.  Ultrashort pulse laser induced bubble creation thresholds in ocular media , 1995, Photonics West.

[22]  J C Dainty,et al.  Single-pass measurements of the wave-front aberrations of the human eye by use of retinal lipofuscin autofluorescence. , 1999, Optics letters.

[23]  P. Kennedy A first-order model for computation of laser-induced breakdown thresholds in ocular and aqueous media. I. Theory , 1995 .

[24]  Dirk Theisen,et al.  Plasma formation in water by picosecond and nanosecond Nd:YAG laser pulses. I. Optical breakdown at threshold and superthreshold irradiance , 1996 .

[25]  C. A. Sacchi,et al.  Experimental Investigation of Optical Breakdown Thresholds in Ocular Media under Single Pulse Irradiation with Different Pulse Durations , 1986 .

[26]  J Mellerio,et al.  Study of the temporal and spatial dynamics of plasmas induced in liquids by nanosecond Nd:YAG laser pulses. 1: Analysis of the plasma starting times. , 1988, Applied optics.

[27]  F. Docchio,et al.  Shielding properties of laser-induced plasmas in ocular media irradiated by single Nd:YAG pulses of different durations. , 1988, Investigative ophthalmology & visual science.

[28]  A. Welch,et al.  Shielding properties of laser-induced breakdown in water for pulse durations from 5 ns to 125 fs. , 1997, Applied Optics.

[29]  C. Grey Morgan,et al.  Lens Aberration Effects in Optical-Frequency Breakdown of Gases , 1969 .

[30]  Reginald Birngruber,et al.  Intraocular Nd:YAG laser surgery: laser-tissue interaction, damage range, and reduction of collateral effects , 1990 .

[31]  F. Docchio Spatial and temporal dynamics of light attenuation and transmission by plasmas induced in liquids by nanosecond Nd:YAG laser pulses , 1991 .

[32]  C. Puliafito,et al.  Plasma formation and shielding by three ophthalmic neodymium-YAG lasers. , 1983, American journal of ophthalmology.