Modiolar Proximity of Three Perimodiolar Cochlear Implant Electrodes

A new generation of cochlear implant electrodes has been designed to position the stimulating contacts close to the modiolus in order to reduce power consumption and increase stimulation selectivity. The purpose of this study was to assess electrode position in the cochlea for three recently designed electrodes. Fifteen cadaveric temporal bones were implanted with one of three perimodiolar electrode arrays: Nucleus Contour; Med-El Combi40+ PM (developmental version); and Clarion HiFocus II. Image-enhanced videofluoroscopy and computer morphometrics were used to assess stimulating contact position relative to the modiolus. The mean distance ( - 1 standard deviation) to the modiolus for all electrode contacts was 0.33 ( - 0.24), 0.30 ( - 0.27) and 0.16 mm ( - 0.19) for the Contour, Combi40+ PM and HiFocus II arrays, respectively. In addition, dynamic videofluoroscopy was used to correlate device-specific insertion characteristics with contact-to-modiolus distance. All three devices were successful in terms of locating electrode contacts very close to the modiolar wall.

[1]  T Lenarz,et al.  A silastic positioner for a modiolus-hugging position of intracochlear electrodes: electrophysiologic effects. , 2000, The American journal of otology.

[2]  Graeme M. Clark,et al.  Computer-Aided Three-Dimensional Reconstruction in Human Cochlear Maps: Measurement of the Lengths of Organ of Corti, Outer Wall, Inner Wall, and Rosenthal's Canal , 1996, The Annals of otology, rhinology, and laryngology.

[3]  A. Hodges,et al.  Novel Intracochlear Electrode Positioner: Effects on Electrode Position , 2000, The Annals of otology, rhinology & laryngology. Supplement.

[4]  G M Clark,et al.  Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array. , 1996, The American journal of otology.

[5]  J. Fayad,et al.  The Clarion electrode positioner: temporal bone studies. , 2000, The American journal of otology.

[6]  W Baumgartner,et al.  Intracochlear position of cochlear implant electrodes. , 1999, Acta oto-laryngologica.

[7]  Antje Aschendorff,et al.  The Nucleus Contour Electrode Array: A Radiological and Histological Study , 2001, The Laryngoscope.

[8]  G. Wang,et al.  In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays. , 1998, The Annals of otology, rhinology & laryngology. Supplement.

[9]  N. Cohen,et al.  Electrode to modiolus proximity: a fluoroscopic and histologic analysis. , 2000, The American journal of otology.

[10]  M. Merzenich,et al.  Strategies to improve electrode positioning and safety in cochlear implants , 1999, IEEE Transactions on Biomedical Engineering.

[11]  M W Skinner,et al.  Localization of cochlear implant electrodes in radiographs. , 2000, Medical physics.