Influence of irradiation sterilization on a semi-solid poly(ortho ester)

Viscous poly(ortho ester) (POE), a promising polymer for controlled release is being investigated as an injectable drug delivery system for peptides, for antiproliferative agents after glaucoma filtering surgery and for antibiotics in the treatment of periodontitis. Due to the chemical lability of POE, the strategies for obtaining a sterile product are limited to aseptic processing and terminal sterilization using high energy radiation. In the first part of the present investigation, we used electron-paramagnetic-resonance (EPR) spectroscopy to evaluate radical formation and radical-induced polymer degradation after irradiation treatment. Due to the viscous nature of POE, radicals were only found at low temperatures or by using the method of ‘spin-trapping’. Several radical species could be distinguished by a variation of the microwave power and the differences of the thermal stability of the radicals. The incorporation of 5-fluorouracil accelerates the degradation of the polymer. In the second part, we have compared the effects of the two commonly applied methods for irradiation sterilization (i.e. gamma and beta rays) on POE and on POE with incorporated 5-fluorouracil and compared these methods to aseptically prepared devices. In addition, we have checked the possibility of preventing radical-induced degradation using two different protecting agents: α-tocopherol at a concentration of 0.1% (w/w) and sterilization under nitrogen monoxide. The weight and number average molecular weight of POE decreased drastically after irradiation treatment and subsequent to irradiation, an accelerated degradation was observed. Generally it was found that higher molecular weight polymers are more affected and that gamma irradiation leads to more degradation than beta treatment. Also, the addition of protecting agents did not significantly prevent polymer degradation. Therefore, we have concluded that irradiation sterilization of POE is not a viable process and aseptic preparation is preferred. Without sterilization POE is stable for about 1 year when kept as monodoses at low temperatures.

[1]  Robert Gurny,et al.  Semi-solid hydrophobic bioerodible poly(ortho ester) for potential application in glaucoma filtering surgery , 1994 .

[2]  Robert Gurny,et al.  Influence of Irradiation Sterilization on Polymers Used as Drug Carriers—A Review , 1997 .

[3]  N. Gopal Radiation sterilization of pharmaceuticals and polymers , 1978 .

[4]  T. Miyazaki,et al.  Electron spin resonance study of radiosterilization of antibiotics: ceftazidime. , 1994, Journal of pharmaceutical sciences.

[5]  G. Armitage,et al.  Development of a drug delivery system for the treatment of periodontal disease based on bioerodible poly(ortho esters). , 1995, Biomaterials.

[6]  R. Gurny,et al.  Subconjunctival biocompatibility of a viscous bioerodable poly(ortho ester). , 1998, Journal of biomedical materials research.

[7]  R. Duncan,et al.  Recent developments in the synthesis and utilization of poly (ortho esters) , 1991 .

[8]  K Mehta,et al.  Dosimetry for quality assurance in electron-beam sterilization of medical devices. , 1993, Medical device technology.

[9]  A. Domb,et al.  Gamma-sterilization-induced radicals in biodegradable drug delivery systems. , 1996, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[10]  J. Duroux,et al.  Gamma irradiation sterilisation of orciprenaline and fenoterol , 1996 .

[11]  R. Gurny,et al.  New generation of poly(ortho esters) : synthesis, characterization, kinetics, sterilization and biocompatibility , 1997 .

[12]  J. Heller,et al.  Pulsatile and delayed release of lysozyme from ointment-like poly(ortho esters) , 1992 .

[13]  L. Varshney,et al.  Effects of ionizing radiations on a pharmaceutical compound, chloramphenicol , 1994 .

[14]  Harold M. Swartz,et al.  The application of EPR spectroscopy in the field of pharmacy , 1994 .

[15]  M. Bernard,et al.  Influence of radiation treatment on theodrenaline: ESR and HPLC study , 1997 .

[16]  R. Gurny,et al.  Purity and stability assessment of a semi-solid poly(ortho ester) used in drug delivery systems. , 1996, Biomaterials.

[17]  R. Gurny,et al.  The use of acidic and basic excipients in the release of 5-fluorouracil and mitomycin C from a semi-solid bioerodible poly(ortho ester) , 1995 .

[18]  T. Miyazaki,et al.  Estimation of irradiation dose of radiosterilized antibiotics by electron spin resonance: ampicillin. , 1994, Journal of pharmaceutical sciences.

[19]  G. P. Jacobs,et al.  A review: Radiation sterilization of pharmaceuticals , 1985 .

[20]  Wilson Bk,et al.  Converting to gamma-radiation sterilization: an overview for medical device manufacturers. , 1993 .

[21]  R. Gurny,et al.  Synthesis and characterization of a new biodegradable semi-solid poly(ortho ester) for drug delivery systems. , 1993, Journal of biomaterials science. Polymer edition.

[22]  K. Bögl,et al.  Influence of Radiation Treatment on Pharmaceuticals-A Review: Alkaloids, Morphine Derivatives, and Antibiotics , 1996 .

[23]  G. P. Jacobs,et al.  A Review of the Effects of Gamma Radiation on Pharmaceutical Materials , 1995, Journal of biomaterials applications.