Cobalt–nickel microcantilevers for biosensing

We present microcantilevers that utilize magnetic actuation for use as mass sensors for bioapplications. The microcantilevers are made of electroplated cobalt–nickel that has low coercivity and high saturation magnetization. The microcantilevers are actuated by applying magnetic fields, and the deflection is measured using a laser Doppler vibrometer. The microfabrication of the microcantilevers is based on two lithography steps, an electroplating step and a sacrificial layer etching step. The magnetic actuation and optical readout using the fabricated cobalt–nickel microcantilever were successfully demonstrated in air under atmospheric pressure and in deionized water. A feedback circuit is used to enhance the quality factor of the microcantilever. The quality factor increased from approximately 550 to 1600 in air and from 7.3 to 10.6 in deionized water. The microcantilevers can be readily functionalized with selective binding molecules and used as a biomass sensor.

[1]  B. Nelson,et al.  Effects of the anion in glycine-containing electrolytes on the mechanical properties of electrodeposited Co–Ni films , 2011 .

[2]  C. Hierold,et al.  An in-plane cobalt-nickel microresonator sensor with magnetic actuation and readout , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[3]  Silvan Schmid,et al.  Superparamagnetic photocurable nanocomposite for the fabrication of microcantilevers , 2011 .

[4]  D. Davis,et al.  Effect of Sulfur Incorporation on Coercivity in CoFe Nanowires , 2010 .

[5]  C. Fonstad,et al.  Use of patterned magnetic films to retain and orient micro-components during fluidic assembly , 2009 .

[6]  Silvan Schmid,et al.  Damping mechanisms of single-clamped and prestressed double-clamped resonant polymer microbeams , 2008 .

[7]  C. Hierold,et al.  Electrostatically actuated nonconductive polymer microresonators in gaseous and aqueous environment , 2008 .

[8]  Jake J. Abbott,et al.  Modeling Magnetic Torque and Force for Controlled Manipulation of Soft-Magnetic Bodies , 2007, IEEE Transactions on Robotics.

[9]  Hans H. Gatzen,et al.  Thin film SmCo magnets for use in electromagnetic microactuators , 2006 .

[10]  Sergio Preidikman,et al.  A semi-analytical tool based on geometric nonlinearities for microresonator design , 2006 .

[11]  Anja Boisen,et al.  Effect of gold coating on the Q-factor of a resonant cantilever , 2005 .

[12]  Wanjun Wang,et al.  A quantitative study on the adhesion property of cured SU-8 on various metallic surfaces , 2005 .

[13]  A. Boisen,et al.  Enhanced functionality of cantilever based mass sensors using higher modes and functionalized particles , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[14]  Tae Song Kim,et al.  Immunoassay of prostate-specific antigen (PSA) using resonant frequency shift of piezoelectric nanomechanical microcantilever. , 2005, Biosensors & bioelectronics.

[15]  Bradley J. Nelson,et al.  Electrodeposition of low residual stress CoNiMnP hard magnetic thin films for magnetic MEMS actuators , 2005 .

[16]  Anja Boisen,et al.  Investigation of the bond strength between the photo-sensitive polymer SU-8 and gold , 2005 .

[17]  Christiane Ziegler,et al.  Cantilever-based biosensors , 2004, Analytical and bioanalytical chemistry.

[18]  M. Sepaniak,et al.  Cantilever transducers as a platform for chemical and biological sensors , 2004 .

[19]  C. Ziegler,et al.  A new cantilever system for gas and liquid sensing. , 2003, Ultramicroscopy.

[20]  N. Myung,et al.  Development of electroplated magnetic materials for MEMS , 2003 .

[21]  T. Thundat,et al.  Bioassay of prostate-specific antigen (PSA) using microcantilevers , 2001, Nature Biotechnology.

[22]  M. Allen,et al.  Development of magnetic materials and processing techniques applicable to integrated micromagnetic devices , 1998 .

[23]  B. Nelson,et al.  Morphology, structure and magnetic properties of cobalt–nickel films obtained from acidic electrolytes containing glycine , 2011 .

[24]  M. Miles,et al.  Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor. , 2001, Ultramicroscopy.