Energy-efficient air conditioning system with combination of radiant cooling and periodic total heat exchanger

The main thrust of this paper is directed toward a novel air conditioning system that can maintain a healthy indoor environment and be energy-efficient. This system consists of a low-temperature regenerative periodic total heat exchanger, radiant ceiling-cooling coil, and conventional air conditioner. The natural cold energy of the tap water in the cooling coil provides comfortable and uniform cooling, and the desiccant-packed bed in the total heat exchanger recovers the indoor energy to handle the fresh air. The performance of each component is discussed, and the actual performance of the whole system is investigated in an office at the Taipei Water Department. The results indicate that using a radiant ceiling-cooling coil to precool the indoor environment enables the traditional window-type air conditioner to reduce two-thirds of the original operating time. In addition, the test of the whole system was conducted in the same office, and it was observed that using this system to handle the incoming air could save 13%–19% of the energy consumption per month during a year-round operation compared to directly introducing untreated fresh air.

[1]  S. Chirarattananon,et al.  An experimental investigation of application of radiant cooling in hot humid climate , 2006 .

[2]  Mehmet Kanoglu,et al.  Energy and exergy analyses of an experimental open-cycle desiccant cooling system. , 2004 .

[3]  Xiaohua Liu,et al.  Effect of regeneration mode on the performance of liquid desiccant packed bed regenerator , 2009 .

[4]  Hugh W. Coleman,et al.  Experimentation, Validation, and Uncertainty Analysis for Engineers , 2009 .

[5]  Ruzhu Wang,et al.  Development of a novel two-stage liquid desiccant dehumidification system assisted by CaCl2 solution using exergy analysis method , 2010 .

[6]  Philip Davies,et al.  Modelling and experimental verification of a solar-powered liquid desiccant cooling system for greenhouse food production in hot climates , 2012 .

[7]  Jianlei Niu,et al.  ENERGY SAVING POSSIBILITIES WITH COOLED-CEILING SYSTEMS , 1995 .

[8]  M. M. Bassuoni,et al.  An experimental study of structured packing dehumidifier/regenerator operating with liquid desiccant , 2011 .

[9]  R. Kosonen,et al.  Cool ceiling system : a European air-conditioning alternative , 1992 .

[10]  N. Enteria,et al.  The role of the thermally activated desiccant cooling technologies in the issue of energy and environment , 2011 .

[11]  Li-Zhi Zhang,et al.  Energy performance of independent air dehumidification systems with energy recovery measures , 2005, Energy.

[12]  K. Daou,et al.  Desiccant cooling air conditioning : a review , 2006 .

[13]  Yi Jiang,et al.  Analytical solutions of coupled heat and mass transfer processes in liquid desiccant air dehumidifier/regenerator , 2007 .

[14]  Tianshu Ge,et al.  Experimental investigation on a one-rotor two-stage rotary desiccant cooling system , 2008 .

[15]  Jianlei Niu,et al.  Indoor humidity behaviors associated with decoupled cooling in hot and humid climates , 2003 .

[16]  Jianlei Niu,et al.  Energy savings potential of chilled-ceiling combined with desiccant cooling in hot and humid climates , 2002 .

[17]  J. E. Janssen,et al.  Ventilation for acceptable indoor air quality , 1989 .

[18]  James R. Sand,et al.  Active desiccant integration with packaged rooftop HVAC equipment , 2005 .