Independence of myoelectric control signals examined using a surface EMG model

The detection volume of the surface electromyographic (EMG) signal was explored using a finite-element model, to examine the feasibility of obtaining independent myoelectric control signals from regions of reinnervated muscle. The selectivity of the surface EMG signal was observed to decrease with increasing subcutaneous fat thickness. The results confirm that reducing the interelectrode distance or using double-differential electrodes can increase surface EMG selectivity in an inhomogeneous volume conductor. More focal control signals can be obtained, at the expense of increased variability, by using the mean square value, rather than the root mean square or average rectified value.

[1]  N. Dimitrova,et al.  Precise and fast calculation of the motor unit potentials detected by a point and rectangular plate electrode. , 1998, Medical engineering & physics.

[2]  T. Milner,et al.  The effects of skinfold thickness on the selectivity of surface EMG. , 1994, Electroencephalography and clinical neurophysiology.

[3]  D. Stegeman,et al.  Motor unit potential contribution to surface electromyography. , 1997, Acta physiologica Scandinavica.

[4]  P. Griffin,et al.  Physical processes associated with the deactivation of dopants in laser annealed silicon , 2002 .

[5]  Jiri Silny,et al.  Spatial Filtering of Noninvasive Multielectrode EMG: Part II-Filter Performance in Theory and Modeling , 1987, IEEE Transactions on Biomedical Engineering.

[6]  R.N. Scott,et al.  A new strategy for multifunction myoelectric control , 1993, IEEE Transactions on Biomedical Engineering.

[7]  Dario Farina,et al.  A novel approach for precise simulation of the EMG signal detected by surface electrodes , 2001, IEEE Trans. Biomed. Eng..

[8]  P. Rosenfalck Intra- and extracellular potential fields of active nerve and muscle fibres. A physico-mathematical analysis of different models. , 1969, Acta physiologica Scandinavica. Supplementum.

[9]  D. Stegeman,et al.  Volume conduction models for surface EMG; confrontation with measurements. , 1997, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[10]  A. Taflove,et al.  Finite element modeling of electromagnetic signal propagation in a phantom arm , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  V. Raicu,et al.  A quantitative approach to the dielectric properties of the skin. , 2000, Physics in medicine and biology.

[12]  D. Stegeman,et al.  Finite limb dimensions and finite muscle length in a model for the generation of electromyographic signals. , 1991, Electroencephalography and clinical neurophysiology.

[13]  Kevin B. Englehart,et al.  A wavelet-based continuous classification scheme for multifunction myoelectric control , 2001, IEEE Transactions on Biomedical Engineering.

[14]  D Graupe,et al.  Stochastic analysis of myoelectric temporal signatures for multifunctional single-site activation of prostheses and orthoses. , 1985, Journal of biomedical engineering.

[15]  H. Clamann Statistical analysis of motor unit firing patterns in a human skeletal muscle. , 1969, Biophysical journal.

[16]  M. Solomonow,et al.  Surface and wire EMG crosstalk in neighbouring muscles. , 1994, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[17]  Daniel W. Stashuk,et al.  Detection of motor unit action potentials with surface electrodes: influence of electrode size and spacing , 1992, Biological Cybernetics.

[18]  Roberto Merletti,et al.  Motor unit recruitment strategies investigated by surface EMG variables. , 2002, Journal of applied physiology.

[19]  C. D. De Luca,et al.  Surface myoelectric signal cross-talk among muscles of the leg. , 1988, Electroencephalography and clinical neurophysiology.

[20]  A. van Oosterom,et al.  Three-Layer Volume Conductor Model and Software Package for Applications in Surface Electromyography , 2002, Annals of Biomedical Engineering.

[21]  J. G. Dijk,et al.  A convenient method to reduce crosstalk in surface EMG , 2001, Clinical Neurophysiology.

[22]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[23]  Todd A. Kuiken,et al.  A multiple-layer finite-element model of the surface EMG signal , 2002, IEEE Transactions on Biomedical Engineering.

[24]  Jacques Duchêne,et al.  A model of EMG generation , 2000, IEEE Transactions on Biomedical Engineering.