A novel islanding detection scheme for synchronous distributed generation using rate of change of exciter voltage over reactive power at DG-Side

Penetration of distributed generation (DG) in distribution networks is rapidly increasing. DGs' application enhances system's reliability and power quality. However, along their benefits, there are some issues. One of the most important issues of DGs' application is the islanding. This paper presents a novel passive islanding detection scheme for synchronous DG based. In the proposed scheme, rate of change of exciter voltage over rate of change of reactive power at the DG-side (dE/dQDG) is taken into account. In reality, the voltage and reactive power of load depend on the exciter of the synchronous generator. Therefore, due to lack of inertia, response of these parameters to small changes is faster than the other passive parameters such as frequency. However, the sensitivity of reactive power at the DG-side and the exciter voltage is much more than reactive power and voltage of the load. So, the reactive power at DG-side and exciter voltage parameters are selected. The performance of the proposed method is investigated in MATLAB/Simulink software on a sample network in the presence of synchronous diesel-generator. The simulation results indicate that the proposed method is capable to detect all islanding and non-islanding conditions even with zero non-detection zones (NDZs) of active and reactive power mismatch.

[1]  Walmir Freitas,et al.  Characteristics of voltage relays for embedded synchronous generators protection , 2007 .

[2]  Ahad Kazemi,et al.  A new technique for islanding detection using voltage phase angle of inverter-based DGs , 2014 .

[3]  Asheesh K. Singh,et al.  A passive islanding detection approach for distributed generation using rate of change of negative sequence voltage and current , 2016, 2016 IEEE Uttar Pradesh Section International Conference on Electrical, Computer and Electronics Engineering (UPCON).

[4]  P. Garcia,et al.  Active Islanding Detection for Multiple Parallel-Connected Inverter-Based Distributed Generators Using High-Frequency Signal Injection , 2014, IEEE Transactions on Power Electronics.

[5]  R. Iravani,et al.  Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit , 2008, IEEE Transactions on Power Electronics.

[6]  Di Zhang,et al.  A novel islanding detection based on adaptive active current disturbance , 2014, 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific).

[7]  Yanjun Li,et al.  Islanding detection method based on system identification , 2016 .

[8]  S. R. Samantaray,et al.  Assessment of ROCPAD Relay for Islanding Detection in Distributed Generation , 2011, IEEE Transactions on Smart Grid.

[9]  Yongli Li,et al.  An Islanding Detection Algorithm for Inverter-Based Distributed Generation Based on Reactive Power Control , 2014, IEEE Transactions on Power Electronics.

[10]  Javad Olamaei,et al.  Islanding Detection based on ROCOV and ROCORP Parameters in the Presence of Synchronous DG Applying the Capacitor Connection Strategy , 2017 .

[11]  J.C.M. Vieira,et al.  Efficient coordination of ROCOF and frequency relays for distributed generation protection by using the application region , 2006, IEEE Transactions on Power Delivery.

[12]  Hamzah Arof,et al.  A Sensitivity Analysis of Different Power System Parameters on Islanding Detection , 2016, IEEE Transactions on Sustainable Energy.

[13]  Emilio Figueres,et al.  Review of anti-islanding techniques in distributed generators , 2010 .

[14]  Amin Kargarian,et al.  Islanding detection method for microgrid based on extracted features from differential transient rate of change of frequency , 2017 .

[15]  J. A. Laghari,et al.  A new islanding detection technique for multiple mini hydro based on rate of change of reactive power and load connecting strategy , 2013 .

[16]  Zhe Chen,et al.  A hybrid islanding detection technique using average rate of voltage change and real power shift , 2009, 2009 IEEE Power & Energy Society General Meeting.

[17]  K. M. Muttaqi,et al.  A Multifeature-Based Approach for Islanding Detection of DG in the Subcritical Region of Vector Surge Relays , 2014, IEEE Transactions on Power Delivery.

[18]  Ali Emadi,et al.  Fast Active Islanding Detection Method Based on Second Harmonic Drifting for Inverter-based Distributed Generation , 2016 .

[19]  Pankaj Gupta,et al.  Active ROCOF Relay for Islanding Detection , 2017, IEEE Transactions on Power Delivery.

[20]  Bhavesh R. Bhalja,et al.  A New Rate of Change of Impedance-based Islanding Detection Scheme in Presence of Distributed Generation , 2014 .

[21]  Rudra Prakash Maheshwari,et al.  Universal islanding detection technique based on rate of change of sequence components of currents for distributed generations , 2016 .

[22]  Bhavesh R. Bhalja,et al.  Islanding detection technique based on inverse hyperbolic secant function , 2016 .

[23]  Shenxing Shi,et al.  Islanding detection method adopting single-phase-operating circuit breaker , 2016 .

[24]  Manoj Fozdar,et al.  Hybrid islanding detection method and priority-based load shedding for distribution networks in the presence of DG units , 2017 .