Research on Three-phase Optimal Power Flow for Distribution Networks Based on Constant Hessian Matrix

The optimal power flow (OPF) problem for active distribution networks with distributed generation (DG) and a variety of discretely adjustable devices (e.g. on-load tap-changers, OLTCs) is essentially a non-convex, non-linear, mixed-integer optimisation problem. In this study, the quadratic model of three-phase OLTCs is proposed by adding branch currents as unknown variables, which guarantee a constant Hessian matrix throughout iterations. This study proposes a three-phase OPF model for active distribution networks, considering a three-phase DG model. The OPF model is solved by an interior point method incorporating a quadratic penalty function as opposed to a Gaussian penalty function. Furthermore, a voltage regulator is also incorporated into the OPF model to form an integrated regulation strategy. The methodology is tested and validated on the IEEE 13-bus three-phase unbalanced test system.

[1]  R. Jabr,et al.  A Primal-Dual Interior Point Method for Optimal Power Flow Dispatching , 2002, IEEE Power Engineering Review.

[2]  E. Sortomme,et al.  Optimal Power Flow for a System of Microgrids with Controllable Loads and Battery Storage , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[3]  Fang Liu,et al.  Decomposed Predictor-Corrector Interior Point Method for Dynamic Optimal Power Flow , 2011, IEEE Transactions on Power Systems.

[4]  S. Conti,et al.  Optimal Dispatching of Distributed Generators and Storage Systems for MV Islanded Microgrids , 2012, IEEE Transactions on Power Delivery.

[5]  Boming Zhang,et al.  Three-phase DFIG steady model and fast three-phase load flow algorithm for distribution power systems , 2010, 2010 International Conference on Power System Technology.

[6]  Wanxing Sheng,et al.  A parallel algorithm of optimal power flow on Hadoop platform , 2016, 2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC).

[7]  Zhengchun Du,et al.  AC–DC optimal reactive power flow model via predictor–corrector primal-dual interior-point method , 2013 .

[8]  G. L. Torres,et al.  Robust Optimal Power Flow Solution Using Trust Region and Interior-Point Methods , 2011, IEEE Transactions on Power Systems.

[9]  Wei Qiao,et al.  Robust AC Optimal Power Flow for Power Networks With Wind Power Generation , 2016, IEEE Transactions on Power Systems.

[10]  Hongbin Sun,et al.  An Extension of FBS Three-Phase Power Flow for Handling PV Nodes in Active Distribution Networks , 2014, IEEE Transactions on Smart Grid.

[11]  Guo Qinglai A Large-scale Reactive Power Optimization Method Based on Gaussian Penalty Function With Discrete Control Variables , 2013 .

[12]  Liu Fang A NEW MODEL OF REACTIVE OPTIMIZATION BASED ON PREDICTOR CORRECTOR PRIMAL DUAL INTERIOR POINT METHOD , 2005 .

[13]  Liao Ping Impact of Wind Speed Correlation on Optimal Power Flow , 2013 .

[14]  Yi Lin,et al.  ADN_Modelica: An Open Source Sequence-Phase Coupled Frame Program for Active Distribution Network Steady State Analysis , 2016 .

[15]  L. Chen A NONLINEAR PREDICTOR-CORRECTOR INTERIOR POINT METHOD FOR REACTIVE POWER OPTIMIZATION IN POWER SYSTEM , 2005 .

[16]  Ju Yunta Three-phase Steady-state Models for Distributed Generators , 2014 .

[17]  R. E. Marsten,et al.  A direct nonlinear predictor-corrector primal-dual interior point algorithm for optimal power flows , 1993 .