Novel Conductive Carbon Black and Polydimethlysiloxane ECG Electrode: A Comparison with Commercial Electrodes in Fresh, Chlorinated, and Salt Water

Abstract In this study, we evaluated the performance of two novel conductive carbon black (CB) and polydimethlysiloxane (PDMS) bio-potential electrodes, with and without an integrated flexible copper mesh, against commercially available electrodes (Polar® textile, Silver-coated textile, and carbon rubber). The electrodes were tested in three types of water (fresh/unfiltered, chlorinated, and salt water). Our testing revealed that our CB/PDMS electrode with integrated copper mesh provided a high-fidelity ECG signal morphologies without any amplitude degradation in all of the types of water tested (N = 10). The non-meshed CB/PDMS electrodes were also subjected to a long-term durability test by the US Navy SCUBA divers during which the electrodes maintained ECG signal quality for a 6 h period of continuous use. The results of a material degradation analysis revealed the CB/PDMS composite material does not exhibit significant changes in physical integrity after prolonged exposure to the test conditions. The newly developed meshed CB/PDMS electrodes have the potential to be used in a wide variety of both dry and wet environments including the challenge of obtaining ECG signals in salt water environments.

[1]  E. Dick,et al.  Cutaneous lesions in swine after decompression: histopathology and ultrastructure. , 1998, Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc.

[2]  K. Chon,et al.  The autonomic effects of cardiopulmonary decompression sickness in swine using principal dynamic mode analysis. , 2013, American journal of physiology. Regulatory, integrative and comparative physiology.

[3]  Ki H. Chon,et al.  Novel Electrodes for Underwater ECG Monitoring , 2014, IEEE Transactions on Biomedical Engineering.

[4]  Patrick Gaydecki,et al.  The use of the Hilbert transform in ECG signal analysis , 2001, Comput. Biol. Medicine.

[5]  Ki H Chon,et al.  Impairment of the autonomic nervous function during decompression sickness in swine. , 2009, Journal of applied physiology.

[6]  T. Kanbayashi,et al.  Diazepam reduces both arterial blood pressure and muscle sympathetic nerve activity in human , 2004, Neuroscience Letters.

[7]  H. Dainer,et al.  Short oxygen prebreathing and intravenous perfluorocarbon emulsion reduces morbidity and mortality in a swine saturation model of decompression sickness. , 2007, Journal of applied physiology.

[8]  B. Takase,et al.  Effects of severe hyperbaric pressure on autonomic nerve functions. , 2002, Military medicine.

[9]  L. Faes,et al.  Cardiovascular and autonomic responses to physiological stressors before and after six hours of water immersion. , 2013, Journal of applied physiology.

[10]  A. Osman,et al.  Cerebro-spinal decompression sickness: report of two cases , 2007, Spinal Cord.

[11]  K. Hirayanagi,et al.  Autonomic nervous activity and stress hormones induced by hyperbaric saturation diving. , 2003, Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc.

[12]  Developmental changes in heart rate variability during exposure to prolonged hypercapnia in piglets , 2002, Autonomic Neuroscience.