The basic scheme of modern medical imaging consists of the following steps: (1) data acquisition, (2) data (image) processing, (3) further data processing by the computer graphic system, (4) image display, and finally (5) visual perception and interpretation. Medical monitors represent a forgotten part of the whole chain. The purpose of this review is to present the key facts about the display technologies used today, as well as their characterization and quality assurance.

[1]  M. Ikeda,et al.  The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs , 2006, European Radiology.

[2]  H. P. Busch,et al.  Digital radiography Results of a survey (part A) and a consensus conference (part B) , 1997, European Radiology.

[3]  N J Hangiandreou,et al.  Cathode ray tube quality control and acceptance testing program: initial results for clinical PACS displays. , 2001, Radiographics : a review publication of the Radiological Society of North America, Inc.

[4]  T D Cradduck,et al.  National electrical manufacturers association , 1983, Journal of the A.I.E.E..

[5]  M. Prokop,et al.  Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions , 2005, European Radiology.

[6]  John E. Aldrich,et al.  Assessment of PACS Display Systems , 2005, Journal of Digital Imaging.

[7]  Ehsan Samei,et al.  Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report. , 2005, Medical physics.

[8]  T. Ishigaki,et al.  Influence of liquid crystal display monitors on observer performance for detection of diffuse pulmonary disease on chest radiographs , 2007, Radiation Medicine.

[9]  K. Y. Lim,et al.  Comparison of observer performance on soft-copy reading of digital chest radiographs: high resolution liquid-crystal display monitors versus cathode-ray tube monitors. , 2008, European journal of radiology.

[10]  Ehsan Samei,et al.  AAPM/RSNA physics tutorial for residents: technological and psychophysical considerations for digital mammographic displays. , 2005, Radiographics : a review publication of the Radiological Society of North America, Inc.

[11]  Mathias Prokop,et al.  Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: an observer preference study. , 2005, AJR. American journal of roentgenology.

[12]  Donald Laming,et al.  Stevens' Power Law , 1997 .

[13]  Mathias Prokop,et al.  Detectability of catheters on bedside chest radiographs: comparison between liquid crystal display and high-resolution cathode-ray tube monitors. , 2005, Radiology.

[14]  Paul Matthijs,et al.  Grayscale resolution : How much is enough? , 2003 .