A practical guide to non-invasive foetal electrocardiogram extraction and analysis

Non-Invasive foetal electrocardiography (NI-FECG) represents an alternative foetal monitoring technique to traditional Doppler ultrasound approaches, that is non-invasive and has the potential to provide additional clinical information. However, despite the significant advances in the field of adult ECG signal processing over the past decades, the analysis of NI-FECG remains challenging and largely unexplored. This is mainly due to the relatively low signal-to-noise ratio of the FECG compared to the maternal ECG, which overlaps in both time and frequency. This article is intended to be used by researchers as a practical guide to NI-FECG signal processing, in the context of the above issues. It reviews recent advances in NI-FECG research including: publicly available databases, NI-FECG extraction techniques for foetal heart rate evaluation and morphological analysis, NI-FECG simulators and the methodology and statistics for assessing the performance of the extraction algorithms. Reference to the most recent work is given, recent findings are highlighted in the form of intermediate summaries, references to open source code and publicly available databases are provided and promising directions for future research are motivated. In particular we emphasise the need and specifications for building a new open reference database of NI-FECG signals, and the need for new algorithms to be benchmarked on the same database, employing the same evaluation statistics. Finally we motivate the need for research in NI-FECG to address morphological analysis, since this represent one of the most promising avenues for this foetal monitoring modality.

[1]  L. Burattini,et al.  Noninvasive Fetal Electrocardiography: An Overview of the Signal Electrophysiological Meaning, Recording Procedures, and Processing Techniques , 2015, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc.

[2]  N. Wessel,et al.  Fetal QRS Detection by means of Kalman Filtering and using the Event Synchronous Canceller , 2012 .

[3]  Reza Sameni,et al.  Extraction of Fetal Cardiac Signals from an Array of Maternal Abdominal Recordings , 2008 .

[4]  K G Rosén,et al.  ECG waveform, short term heart rate variability and plasma catecholamine concentrations in response to hypoxia in intrauterine growth retarded guinea-pig fetuses. , 1991, Journal of developmental physiology.

[5]  Gari D Clifford,et al.  Multimodal heart beat detection using signal quality indices , 2015, Physiological measurement.

[6]  Luigi Raffo,et al.  Identification of fetal QRS complexes in low density non-invasive biopotential recordings , 2013, Computing in Cardiology 2013.

[7]  David A. Clifton,et al.  Fusing Continuous-Valued Medical Labels Using a Bayesian Model , 2015, Annals of Biomedical Engineering.

[8]  Gari D Clifford,et al.  An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms , 2016, Physiological measurement.

[9]  Asoke K. Nandi,et al.  Noninvasive fetal electrocardiogram extraction: blind separation versus adaptive noise cancellation , 2001, IEEE Transactions on Biomedical Engineering.

[10]  B. Brambati,et al.  THE INTRAVENTRICULAR CONDUCTION TIME OF FETAL HEART IN UNCOMPLICATED PREGNANCIES , 1980, British journal of obstetrics and gynaecology.

[11]  Christian Jutten,et al.  Fetal ECG Extraction by Extended State Kalman Filtering Based on Single-Channel Recordings , 2013, IEEE Transactions on Biomedical Engineering.

[12]  B. Hayes-Gill,et al.  Intrapartum signal quality with external fetal heart rate monitoring: a two way trial of external Doppler CTG ultrasound and the abdominal fetal electrocardiogram , 2012, Archives of Gynecology and Obstetrics.

[13]  P. Boyce,et al.  Increased risk of postnatal depression after emergency caesarean section , 1992, The Medical journal of Australia.

[14]  R. Freeman,et al.  Signal ambiguity resulting in unexpected outcome with external fetal heart rate monitoring. , 2008, American journal of obstetrics and gynecology.

[15]  J. Bernardes,et al.  Twenty‐five years after the FIGO guidelines for the use of fetal monitoring: Time for a simplified approach? , 2010, International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics.

[16]  J. Neilson Fetal electrocardiogram (ECG) for fetal monitoring during labour. , 2012, The Cochrane database of systematic reviews.

[17]  S. Cerutti,et al.  Variability analysis of fetal heart rate signals as obtained from abdominal electrocardiographic recordings , 1986, Journal of perinatal medicine.

[18]  Jinwei Sun,et al.  A multichannel nonlinear adaptive noise canceller based on generalized FLANN for fetal ECG extraction , 2015 .

[19]  Ikaro Silva,et al.  Robust detection of heart beats in multimodal data , 2015, Physiological measurement.

[20]  Christian Jutten,et al.  Multichannel ECG and Noise Modeling: Application to Maternal and Fetal ECG Signals , 2007 .

[21]  Gari D Clifford,et al.  Non-invasive fetal ECG analysis , 2014, Physiological measurement.

[22]  David A. Borkholder,et al.  Fetal ECG extraction from abdominal recordings using array signal processing , 2013, Computing in Cardiology 2013.

[23]  S. Lange,et al.  Multicentre study of fetal cardiac time intervals using magnetocardiography , 2002, BJOG : an international journal of obstetrics and gynaecology.

[24]  Radek Martinek,et al.  Enhanced processing and analysis of multi-channel non-invasive abdominal foetal ECG signals during labor and delivery , 2015 .

[25]  A. Boulesteix,et al.  What is the “normal” fetal heart rate? , 2013, PeerJ.

[26]  L. Billeci,et al.  An efficient unsupervised fetal QRS complex detection from abdominal maternal ECG , 2014, Physiological measurement.

[27]  Javier Jiménez Candil,et al.  [QT interval and acute myocardial ischemia: past promises, new evidences]. , 2008, Revista espanola de cardiologia.

[28]  Hagen Malberg,et al.  Robust fetal ECG extraction and detection from abdominal leads , 2014, Physiological measurement.

[29]  Christian Jutten,et al.  A Nonlinear Bayesian Filtering Framework for ECG Denoising , 2007, IEEE Transactions on Biomedical Engineering.

[30]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[31]  George B. Moody,et al.  An Open-source Toolbox for Analysing and Processing PhysioNet Databases in MATLAB and Octave , 2014, Journal of open research software.

[32]  Shuang Song,et al.  Influence of Electrode Placement on Signal Quality for Ambulatory Pregnancy Monitoring , 2014, Comput. Math. Methods Medicine.

[33]  Thom F. Oostendorp,et al.  Modelling the fetal ECG , 1989 .

[34]  Zulfiqar A Bhutta,et al.  Stillbirths: what difference can we make and at what cost? , 2011, The Lancet.

[35]  H. Jongsma,et al.  Electrical properties of tissues involved in the conduction of foetal ECG , 1989, Medical and Biological Engineering and Computing.

[36]  Barrie Hayes-Gill,et al.  Accuracy and Reliability of Uterine Contraction Identification Using Abdominal Surface Electrodes , 2012 .

[37]  Gerardo Chowell,et al.  Theoretical perspectives on the infectiousness of Ebola virus disease , 2015, Theoretical Biology and Medical Modelling.

[38]  Guangchen Liu,et al.  An adaptive integrated algorithm for noninvasive fetal ECG separation and noise reduction based on ICA-EEMD-WS , 2015, Medical & Biological Engineering & Computing.

[39]  Qiao Li,et al.  ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction , 2013, IEEE Transactions on Biomedical Engineering.

[40]  Joachim Behar,et al.  A Comparison of Single Channel Fetal ECG Extraction Methods , 2014, Annals of Biomedical Engineering.

[41]  Sandy Weininger,et al.  Fetal pulse oximetry and cesarean delivery. , 2006, The New England journal of medicine.

[42]  G. Clifford,et al.  Clinically accurate fetal ECG parameters acquired from maternal abdominal sensors. , 2011, American journal of obstetrics and gynecology.

[43]  G D Clifford,et al.  Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms , 2012, Physiological measurement.

[44]  Hartmut Dickhaus,et al.  Fetal QRS detection and RR interval measurement in noninvasively registered abdominal ECGs , 2013, Computing in Cardiology 2013.

[45]  G. Clifford,et al.  A Review of Fetal ECG Signal Processing; Issues and Promising Directions. , 2010, The open pacing, electrophysiology & therapy journal.

[46]  J. Stinstra The reliability of the fetal magnetocardiogram , 2001 .

[47]  D. Maulik,et al.  Guidelines and recommendations for safe use of Doppler ultrasound in perinatal applications , 2001, The Journal of maternal-fetal medicine.

[48]  E. Mulder,et al.  Fetal electrocardiography: feasibility of long‐term fetal heart rate recordings , 2009, BJOG : an international journal of obstetrics and gynaecology.

[49]  R. Modre-Osprian,et al.  A robust algorithm for fetal QRS detection using non-invasive maternal abdomenal ECGs , 2013, Computing in Cardiology 2013.

[50]  G. Saha,et al.  Fetal ECG extraction from single-channel maternal ECG using singular value decomposition , 1997, IEEE Transactions on Biomedical Engineering.

[51]  Vito Starc Non-invasive fetal multilead RR interval determination from maternal abdominal recordings: The Physionet/CinC Challenge 2013 , 2013, Computing in Cardiology 2013.

[52]  J. Bernardes,et al.  Evaluation of interobserver agreement of cardiotocograms , 1997, International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics.

[53]  Henggui Zhang,et al.  A multi-step method with signal quality assessment and fine-tuning procedure to locate maternal and fetal QRS complexes from abdominal ECG recordings , 2014, Physiological measurement.

[54]  Said Raghay,et al.  A new method for the extraction of fetal ECG from the dependent abdominal signals using blind source separation and adaptive noise cancellation techniques , 2015, Theoretical Biology and Medical Modelling.

[55]  Lenka Lhotská,et al.  Advanced signal processing techniques for fetal ECG analysis , 2013, Computing in Cardiology 2013.

[56]  Gari D Clifford,et al.  Combining and benchmarking methods of foetal ECG extraction without maternal or scalp electrode data , 2014, Physiological measurement.

[57]  Massimo Mischi,et al.  Estimation of internal uterine pressure by joint amplitude and frequency analysis of electrohysterographic signals , 2008, Physiological measurement.

[58]  Christian Jutten,et al.  Fetal QRS complex detection based on three-way tensor decomposition , 2013, Computing in Cardiology 2013.

[59]  K. Rosen,et al.  The effects of intrapartum hypoxia on the fetal QT interval , 2004, BJOG : an international journal of obstetrics and gynaecology.

[60]  S Abboud,et al.  Quantification of the fetal electrocardiogram using averaging technique. , 1990, Computers in biology and medicine.

[61]  C. East,et al.  The effect of intrapartum fetal pulse oximetry, in the presence of a nonreassuring fetal heart rate pattern, on operative delivery rates: a multicenter, randomized, controlled trial (the FOREMOST trial). , 2006, American journal of obstetrics and gynecology.

[62]  Gábor Hosszú,et al.  Fetal phonocardiography - Past and future possibilities , 2011, Comput. Methods Programs Biomed..

[63]  Pablo Laguna,et al.  Noninvasive fetal ECG estimation based on linear transformations , 2013, Computing in Cardiology 2013.

[64]  H. Lagercrantz,et al.  The relationship between circulating catecholamines and ST waveform in the fetal lamb electrocardiogram during hypoxia. , 1984, American journal of obstetrics and gynecology.

[65]  M. Peters,et al.  Monitoring the fetal heart non-invasively: a review of methods , 2001, Journal of perinatal medicine.

[66]  Raymond G Kennedy Electronic fetal heart rate monitoring: retrospective reflections on a twentieth-century technology , 1998, Journal of the Royal Society of Medicine.

[67]  K. Greene,et al.  Changes in the ST waveform of the fetal lamb electrocardiogram with hypoxemia. , 1982, American journal of obstetrics and gynecology.

[68]  Peng Li,et al.  Systematic methods for fetal electrocardiographic analysis: Determining the fetal heart rate, RR interval and QT interval , 2013, Computing in Cardiology 2013.

[69]  N. Fisk,et al.  Non‐invasive fetal electrocardiography in singleton and multiple pregnancies , 2003, BJOG : an international journal of obstetrics and gynaecology.

[70]  MA Hasan,et al.  Detection and Processing Techniques of FECG Signal for Fetal Monitoring , 2009, Biological Procedures Online.

[71]  Fernando Andreotti,et al.  A Bayesian Filtering Framework for accurate extracting of the non-invasive FECG morphology , 2014, Computing in Cardiology 2014.

[72]  Rui Rodrigues,et al.  Fetal ECG detection in abdominal recordings: A method for QRS location , 2013, Computing in Cardiology 2013.

[73]  S. B. Barnett,et al.  Guidelines and recommendations for safe use of Doppler ultrasound in perinatal applications , 2001 .

[74]  J. Crowe,et al.  Compact long-term recorder for the transabdominal foetal and maternal electrocardiogram , 2006, Medical and Biological Engineering and Computing.

[75]  J. Nuovo,et al.  Interpretation of the electronic fetal heart rate during labor. , 1999, American family physician.

[76]  Ali Ghaffari,et al.  Robust fetal QRS detection from noninvasive abdominal electrocardiogram based on channel selection and simultaneous multichannel processing , 2015, Australasian Physical & Engineering Sciences in Medicine.

[77]  G. Camps,et al.  Fetal ECG extraction using an FIR neural network , 2001, Computers in Cardiology 2001. Vol.28 (Cat. No.01CH37287).

[78]  Joachim Behar,et al.  Extraction of clinical information from the non-invasive fetal electrocardiogram , 2016, ArXiv.

[79]  Joachim Behar,et al.  Crowd-Sourced Annotation of ECG Signals Using Contextual Information , 2013, Annals of Biomedical Engineering.

[80]  M Macklin,et al.  Changes in the conduction of the fetal electrocardiogram to the maternal abdominal surface during gestation. , 1977, American journal of obstetrics and gynecology.

[81]  Qiao Li,et al.  Open source Java-based ECG analysis software and Android app for Atrial Fibrillation screening , 2013, Computing in Cardiology 2013.

[82]  J. Neilson Fetal electrocardiogram (ECG) for fetal monitoring during labour. , 2015, The Cochrane database of systematic reviews.

[83]  Pierre-Yves Gumery,et al.  A multi-modal approach using a non-parametric model to extract fetal ECG , 2015, 2015 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[84]  Christian Jutten,et al.  Fetal ECG extraction from a single sensor by a non-parametric modeling , 2012, 2012 Proceedings of the 20th European Signal Processing Conference (EUSIPCO).

[85]  E. Graham,et al.  Intrapartum Electronic Fetal Heart Rate Monitoring and the Prevention of Perinatal Brain Injury , 2006, Obstetrics and gynecology.

[86]  I Kjellmer,et al.  Myocardial metabolism in relation to electrocardiographic changes and cardiac function during graded hypoxia in the fetal lamb. , 1981, Acta physiologica Scandinavica.

[87]  I. Hildingsson,et al.  Postoperative pain after cesarean birth affects breastfeeding and infant care. , 2007, Journal of obstetric, gynecologic, and neonatal nursing : JOGNN.

[88]  Javier Jiménez Candil,et al.  Intervalo QT e isquemia miocárdica aguda: viejas promesas, nuevas evidencias , 2008 .

[89]  P. Langley,et al.  Extracting fetal heart beats from maternal abdominal recordings: selection of the optimal principal components , 2014, Physiological measurement.

[90]  Sebastian Zaunseder,et al.  An ECG simulator for generating maternal-foetal activity mixtures on abdominal ECG recordings , 2014, Physiological measurement.

[91]  Rodica Strungaru,et al.  Fetal ECG extraction during labor using an adaptive maternal beat subtraction technique , 2007, Biomedizinische Technik. Biomedical engineering.

[92]  Roger Abächerli,et al.  Cancellation of the maternal and extraction of the fetal ECG in noninvasive recordings , 2013, Computing in Cardiology 2013.

[93]  Patrick E. McSharry,et al.  A dynamical model for generating synthetic electrocardiogram signals , 2003, IEEE Transactions on Biomedical Engineering.

[94]  Joos Vandewalle,et al.  Fetal electrocardiogram extraction by blind source subspace separation , 2000, IEEE Transactions on Biomedical Engineering.

[95]  Rik Vullings,et al.  Novel Bayesian Vectorcardiographic Loop Alignment for Improved Monitoring of ECG and Fetal Movement , 2013, IEEE Transactions on Biomedical Engineering.

[96]  Reza Sameni,et al.  A robust framework for noninvasive extraction of fetal electrocardiogram signals , 2013, Computing in Cardiology 2013.

[97]  B. Widrow,et al.  Adaptive noise cancelling: Principles and applications , 1975 .

[98]  N. Fisk,et al.  Non‐invasive intrapartum fetal ECG: preliminary report , 2005, BJOG : an international journal of obstetrics and gynaecology.

[99]  Sebastian Zaunseder,et al.  Effects of ECG sampling rate on QT interval variability measurement , 2016, Biomed. Signal Process. Control..

[100]  Mika P. Tarvainen,et al.  Advanced maternal ECG removal and noise reduction for application of fetal QRS detection , 2013, Computing in Cardiology 2013.

[101]  Mohammad B. Shamsollahi,et al.  Fetal electrocardiogram R-peak detection using robust tensor decomposition and extended Kalman filtering , 2013, Computing in Cardiology 2013.

[102]  Fernando Andreotti,et al.  R-peak estimation using multimodal lead switching , 2014, Computing in Cardiology 2014.

[103]  G. Saade,et al.  A Randomized Trial of Intrapartum Fetal ECG ST-Segment Analysis , 2015 .

[104]  Massimo Mischi,et al.  A robust fetal ECG detection method for abdominal recordings , 2007, Physiological measurement.

[105]  Christian Jutten,et al.  Multichannel Electrocardiogram Decomposition Using Periodic Component Analysis , 2008, IEEE Transactions on Biomedical Engineering.

[106]  Bart De Schutter,et al.  DAISY : A database for identification of systems , 1997 .

[107]  Thomas Downs,et al.  Fetal heart rate pattern notification guidelines and suggested management algorithm for intrapartum electronic fetal heart rate monitoring. , 2007, The Permanente journal.

[108]  B. Hayes-Gill,et al.  Comparison of non-invasive fetal electrocardiogram to Doppler cardiotocogram during the 1st stage of labor , 2010, Journal of perinatal medicine.

[109]  M. Tarvainen,et al.  Principal component model for maternal ECG extraction in fetal QRS detection , 2014, Physiological measurement.

[110]  Sebastian Zaunseder,et al.  fecgsyngui: A GUI interface to fecgsyn for simulation of maternal-foetal activity mixtures on abdominal electrocardiogram recordings , 2014, Computing in Cardiology 2014.

[111]  E. W. Hancock,et al.  AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American , 2009, Journal of the American College of Cardiology.