Feasibility of pulmonary MRI for nodule detection in comparison to computed tomography

Background To assess the feasibility of various magnetic resonance imaging (MRI) sequences for the detection of pulmonary nodules by comparing the detection rate of computed tomography (CT). Methods Forty-two patients with pulmonary nodules detected by multi-slice CT (MSCT) were prospectively enrolled in the present study between November 2016 and February 2017. Chest MRI was acquired within 24 h of CT. The MRI protocol included free-breathing radial VIBE (r-VIBE) and a conventional breathhold T1-weighted VIBE (C-VIBE) were analyzed by two independent radiologists. Both detection and morphology results of each MRI image were recorded. Subjective image evaluation in terms of overall nodule morphology on the MRI images was carried out using the 4-point scoring criteria. The MRI results were compared with those from CT, with the results of MSCT serving as the reference standard. Results Two hundred and fifty-eight solid pulmonary nodules in 42 patients were detected by CT. The r-VIBE correctly detected 94% of the pulmonary nodules as compared with CT. The detection rate increased to 100% for lesions ≥6 mm. The C-VIBE had a lower overall detection rate (64.3%) of pulmonary nodules. The difference in the subjective image evaluation scores between the two sequences was statistically significant ( p  < 0.001). Conclusion Significantly increased detection rates were obtained with free-breathing r-VIBE as compared with C-VIBE for the detection of pulmonary nodules and also provided more information when evaluating the nodules as compared with C-VIBE.

[1]  I. Grudzinski,et al.  MR Imaging of Pulmonary Nodules: Detection Rate and Accuracy of Size Estimation in Comparison to Computed Tomography , 2016, PloS one.

[2]  J. Biederer,et al.  MRI of pulmonary nodules: technique and diagnostic value , 2008, Cancer imaging : the official publication of the International Cancer Imaging Society.

[3]  Danny C. Kim,et al.  Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient Echo Sequence: A Viable Alternative for Contrast-Enhanced Liver Imaging in Patients Unable to Suspend Respiration , 2011, Investigative radiology.

[4]  Hilde van der Togt,et al.  Publisher's Note , 2003, J. Netw. Comput. Appl..

[5]  Vikas Gulani,et al.  Quantitative High-Resolution Renal Perfusion Imaging Using 3-Dimensional Through-Time Radial Generalized Autocalibrating Partially Parallel Acquisition , 2014, Investigative radiology.

[6]  T. Lehnert,et al.  Comparative evaluation of non-contrast CAIPIRINHA-VIBE 3T-MRI and multidetector CT for detection of pulmonary nodules: In vivo evaluation of diagnostic accuracy and image quality. , 2016, European journal of radiology.

[7]  Hersh Chandarana,et al.  Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI , 2014, European Radiology.

[8]  A. Wetter,et al.  Thoracic staging of non-small-cell lung cancer using integrated 18F-FDG PET/MR imaging: diagnostic value of different MR sequences , 2015, European Journal of Nuclear Medicine and Molecular Imaging.

[9]  C. Geppert,et al.  Pulmonary nodules in patients with primary malignancy: comparison of hybrid PET/MR and PET/CT imaging. , 2013, Radiology.

[10]  Shivani Kumar,et al.  MRI in radiotherapy for lung cancer: A free-breathing protocol at 3T. , 2017, Practical radiation oncology.

[11]  Li Feng,et al.  Free-Breathing Contrast-Enhanced Multiphase MRI of the Liver Using a Combination of Compressed Sensing, Parallel Imaging, and Golden-Angle Radial Sampling , 2013, Investigative radiology.

[12]  G. Gamsu Magnetic resonance imaging in lung cancer. , 1986, Chest.

[13]  H. Kang,et al.  Free-breathing radial volumetric interpolated breath-hold examination vs breath-hold cartesian volumetric interpolated breath-hold examination magnetic resonance imaging of the liver at 1.5T. , 2016, World journal of radiology.

[14]  Hans-Ulrich Kauczor,et al.  MRI of the lung: state of the art. , 2012, Diagnostic and interventional radiology.

[15]  Richard C. Semelka,et al.  Free breathing three‐dimensional gradient echo‐sequence with radial data sampling (radial 3D‐GRE) examination of the pancreas: Comparison with standard 3D‐GRE volumetric interpolated breathhold examination (VIBE) , 2013, Journal of magnetic resonance imaging : JMRI.

[16]  H. Schild,et al.  Highlights T 2 w MultiVane images can be aqcuired during free breathing The T 2 w MultiVane sequence shows great artifact reduction and better image quality than FSE The MultiVane , 2015 .

[17]  Y. Ohno,et al.  Pulmonary high‐resolution ultrashort TE MR imaging: Comparison with thin‐section standard‐ and low‐dose computed tomography for the assessment of pulmonary parenchyma diseases , 2016, Journal of magnetic resonance imaging : JMRI.

[18]  Geoffrey McLennan,et al.  Recent technological and application developments in computed tomography and magnetic resonance imaging for improved pulmonary nodule detection and lung cancer staging , 2010, Journal of magnetic resonance imaging : JMRI.

[19]  D. Moses,et al.  Feasibility of free breathing Lung MRI for Radiotherapy using non-Cartesian k-space acquisition schemes. , 2017, The British journal of radiology.

[20]  D. Moses,et al.  Magnetic resonance imaging in lung: a review of its potential for radiotherapy. , 2016, The British journal of radiology.

[21]  J. Biederer,et al.  Simulated pulmonary nodules implanted in a dedicated porcine chest phantom: sensitivity of MR imaging for detection. , 2003, Radiology.

[22]  Brian M Dale,et al.  Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: preliminary observations. , 2011, AJR. American journal of roentgenology.