Measurement time and statistics for a noise thermometer with a synthetic-noise reference

This paper describes methods for reducing the statistical uncertainty in measurements made by noise thermometers using digital cross-correlators and, in particular, for thermometers using pseudo-random noise for the reference signal. First, a discrete-frequency expression for the correlation bandwidth for conventional noise thermometers is derived. It is shown how an alternative frequency-domain computation can be used to eliminate the spectral response of the correlator and increase the correlation bandwidth. The corresponding expressions for the uncertainty in the measurement of pseudo-random noise in the presence of uncorrelated thermal noise are then derived. The measurement uncertainty in this case is less than that for true thermal-noise measurements. For pseudo-random sources generating a frequency comb, an additional small reduction in uncertainty is possible, but at the cost of increasing the thermometer's sensitivity to non-linearity errors. A procedure is described for allocating integration times to further reduce the total uncertainty in temperature measurements. Finally, an important systematic error arising from the calculation of ratios of statistical variables is described.

[1]  H. Klein,et al.  Measurement of the Thermodynamic Temperature of 4He at Various Vapour Pressures by a Noise Thermometer , 1979 .

[2]  David White,et al.  A Ratiometric Method for Johnson Noise Thermometry Using a Quantized Voltage Noise Source , 2003 .

[3]  John M. Martinis,et al.  Progress on Johnson noise thermometry using a quantum voltage noise source for calibration , 2005, IEEE Transactions on Instrumentation and Measurement.

[4]  D. R. White The noise bandwidth of sampled data systems , 1989 .

[5]  Sae Woo Nam,et al.  Resistance-Based Scaling of Noise Temperatures From 1 kHz to 1 MHz , 2007, IEEE Transactions on Instrumentation and Measurement.

[6]  Peter Kittel,et al.  Comment on the equivalent noise bandwidth approximation , 1977 .

[7]  John M. Martinis,et al.  An AC Josephson source for Johnson noise thermometry , 2002, Conference Digest Conference on Precision Electromagnetic Measurements.

[8]  S. P. Benz,et al.  Constraints on a synthetic-noise source for Johnson noise thermometry , 2008 .

[9]  B. Taylor,et al.  CODATA recommended values of the fundamental physical constants: 2006 | NIST , 2007, 0801.0028.

[10]  S. Benz,et al.  A Determination of the Ratio of the Zinc Freezing Point to the Tin Freezing Point by Noise Thermometry , 2008 .

[11]  S. Rice Mathematical analysis of random noise , 1944 .

[12]  D. Wait The sensitivity of the Dicke radiometer , 1967 .

[13]  J. W. Tukey,et al.  The Measurement of Power Spectra from the Point of View of Communications Engineering , 1958 .

[14]  A. Sripad,et al.  A necessary and sufficient condition for quantization errors to be uniform and white , 1977 .

[15]  D. White,et al.  Detection of corruption in Gaussian processes with application to noise thermometry , 1998 .

[16]  John M. Martinis,et al.  A New Approach to Johnson Noise Thermometry using a Josephson Quantized Voltage Source , 2002 .

[17]  Ronald N. Bracewell,et al.  The Fourier Transform and Its Applications , 1966 .

[18]  David White,et al.  Preamplifier limitations on the accuracy of Johnson noise thermometers , 2000 .

[19]  Weston L. Tew,et al.  Johnson Noise Thermometry near the Zinc Freezing Point Using Resistance-Based Scaling , 2007 .

[20]  John M. Martinis,et al.  Johnson noise thermometry measurements using a quantized voltage noise source for calibration , 2003, IEEE Trans. Instrum. Meas..

[21]  M. J. Roberts,et al.  Effect of filter frequency response on the uncertainty in measuring statistical estimators of input noise , 1985 .

[22]  A Actis,et al.  The status of Johnson noise thermometry , 1996 .