Deterministic sequential isolation of floating cancer cells under continuous flow.

Isolation of rare cells, such as circulating tumor cells, has been challenging because of their low abundance and limited timeframes of expressions of relevant cell characteristics. In this work, we devise a novel hydrodynamic mechanism to sequentially trap and isolate floating cells in biosamples. We develop a microfluidic device for the sequential isolation of floating cancer cells through a series of microsieves to obtain up to 100% trapping yield and >95% sequential isolation efficiency. We optimize the trappers' dimensions and locations through both computational and experimental analyses using microbeads and cells. Furthermore, we investigated the functional range of flow rates for effective sequential cell isolation by taking the cell deformability into account. We verify the cell isolation ability using the human breast cancer cell line MDA-MB-231 with perfect agreement with the microbead results. The viability of the isolated cells can be maintained for direct identification of any cell characteristics within the device. We further demonstrate that this device can be applied to isolate the largest particles from a sample containing multiple sizes of particles, revealing its possible applicability in isolation of circulating tumor cells in cancer patients' blood. Our study provides a promising sequential cell isolation strategy with high potential for rapid detection and analysis of general floating cells, including circulating tumor cells and other rare cell types.

[1]  Robert Rosenberg,et al.  Detection of circulating tumor cells in blood using an optimized density gradient centrifugation. , 2003, Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer.

[2]  E. Solomon INTRODUCTION TO HUMAN ANATOMY AND PHYSIOLOGY , 2008 .

[3]  Jongyoon Han,et al.  Enhancing malaria diagnosis through microfluidic cell enrichment and magnetic resonance relaxometry detection , 2015, Scientific Reports.

[4]  N. Melosh,et al.  Silicon chip-based patch-clamp electrodes integrated with PDMS microfluidics. , 2004, Biosensors & bioelectronics.

[5]  T. Huang,et al.  Acoustic separation of circulating tumor cells , 2015, Proceedings of the National Academy of Sciences.

[6]  Richard Superfine,et al.  Mechanical stiffness grades metastatic potential in patient tumor cells and in cancer cell lines. , 2011, Cancer research.

[7]  D. Weitz,et al.  Fluorescence-activated droplet sorting (FADS): efficient microfluidic cell sorting based on enzymatic activity. , 2009, Lab on a chip.

[8]  Li Wang,et al.  Microfluidic device with integrated microfilter of conical-shaped holes for high efficiency and high purity capture of circulating tumor cells , 2014, Scientific Reports.

[9]  D. Beebe,et al.  The present and future role of microfluidics in biomedical research , 2014, Nature.

[10]  Jianping Fu,et al.  Elastomeric microposts integrated into microfluidics for flow-mediated endothelial mechanotransduction analysis. , 2012, Lab on a chip.

[11]  Dong Sun,et al.  Enhanced cell sorting and manipulation with combined optical tweezer and microfluidic chip technologies. , 2011, Lab on a chip.

[12]  Michael D. Henry,et al.  Resistance to Fluid Shear Stress Is a Conserved Biophysical Property of Malignant Cells , 2012, PloS one.

[13]  Marcos,et al.  Dynamic aspects of electroosmotic flow in rectangular microchannels , 2004 .

[14]  J M Paulus,et al.  Platelet size in man. , 1975, Blood.

[15]  G. Whitesides,et al.  Soft lithography in biology and biochemistry. , 2001, Annual review of biomedical engineering.

[16]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[17]  Jean-Louis Viovy,et al.  Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells , 2008, Proceedings of the National Academy of Sciences.

[18]  Subra Suresh,et al.  Biomechanics and biophysics of cancer cells , 2007 .

[19]  Thomas Braschler,et al.  Continuous-flow electrical lysis device with integrated control by dielectrophoretic cell sorting. , 2010, Lab on a chip.

[20]  Katsuo Kurabayashi,et al.  Surface‐Micromachined Microfiltration Membranes for Efficient Isolation and Functional Immunophenotyping of Subpopulations of Immune Cells , 2013, Advanced healthcare materials.

[21]  P. Sajeesh,et al.  Particle separation and sorting in microfluidic devices: a review , 2014 .

[22]  Menake E Piyasena,et al.  Multinode acoustic focusing for parallel flow cytometry. , 2012, Analytical chemistry.

[23]  Allan Guan,et al.  Streamline based design guideline for deterministic microfluidic hydrodynamic single cell traps. , 2015, Biomicrofluidics.

[24]  Marcos,et al.  Frequency-dependent laminar electroosmotic flow in a closed-end rectangular microchannel. , 2004, Journal of colloid and interface science.

[25]  Siyang Zheng,et al.  Membrane microfilter device for selective capture, electrolysis and genomic analysis of human circulating tumor cells. , 2007, Journal of chromatography. A.

[26]  E. L. Persons STUDIES ON RED BLOOD CELL DIAMETER: III. The Relative Diameter of Immature (Reticulocytes) and Adult Red Blood Cells in Health and Anemia, Especially in Pernicious Anemia. , 1929, The Journal of clinical investigation.

[27]  C. Lim,et al.  Isolation and retrieval of circulating tumor cells using centrifugal forces , 2013, Scientific Reports.

[28]  Brittain,et al.  Prototyping of masks, masters, and stamps/molds for soft lithography using an office printer and photographic reduction , 2000, Analytical chemistry.

[29]  Dieter Falkenhagen,et al.  Enrichment of circulating tumor cells from a large blood volume using leukapheresis and elutriation: Proof of concept , 2011, Cytometry. Part B, Clinical cytometry.

[30]  Brian J. Kirby,et al.  Microfluidic transport in microdevices for rare cell capture , 2012, Electrophoresis.

[31]  T. Price,et al.  Circulating tumour cells: the evolving concept and the inadequacy of their enrichment by EpCAM-based methodology for basic and clinical cancer research. , 2014, Annals of oncology : official journal of the European Society for Medical Oncology.

[32]  Guangyu Liu,et al.  Multiparametric Biomechanical and Biochemical Phenotypic Profiling of Single Cancer Cells Using an Elasticity Microcytometer. , 2016, Small.

[33]  Todd Thorsen,et al.  High-density microfluidic arrays for cell cytotoxicity analysis. , 2007, Lab on a chip.

[34]  Nam-Trung Nguyen,et al.  Rare cell isolation and analysis in microfluidics. , 2014, Lab on a chip.

[35]  Maciej Zborowski,et al.  Magnetophoretic Cell Sorting Is a Function of Antibody Binding Capacity , 2003, Biotechnology progress.

[36]  H. Amini,et al.  Label-free cell separation and sorting in microfluidic systems , 2010, Analytical and bioanalytical chemistry.

[37]  Rajan P Kulkarni,et al.  High efficiency vortex trapping of circulating tumor cells. , 2015, Biomicrofluidics.

[38]  Xiaojun Feng,et al.  Hydrodynamic gating valve for microfluidic fluorescence-activated cell sorting. , 2010, Analytica chimica acta.

[39]  Marcos,et al.  A microfluidic chemotaxis assay to study microbial behavior in diffusing nutrient patches , 2008 .

[40]  Dino Di Carlo,et al.  Hydrodynamic stretching of single cells for large population mechanical phenotyping , 2012, Proceedings of the National Academy of Sciences.

[41]  G. B. Jeffery The motion of ellipsoidal particles immersed in a viscous fluid , 1922 .

[42]  Roman Stocker,et al.  Separation of microscale chiral objects by shear flow. , 2009, Physical review letters.