An Adaptive Dual-Window Step Detection Method for a Waist-Worn Inertial Navigation System

In waist-worn pedestrian navigation systems, the periodic vertical acceleration peak signal at body centre of gravity is widely used for detecting steps. Due to vibration and waist shaking interference, accelerometer output signals contain false peaks and thus reduce step detection accuracy. This paper analyses the relationship between periodic acceleration at pedestrian centre of gravity and walking stance during walking. An adaptive dual-window step detection method is proposed based on this analysis. The peak signal is detected by a dual-window and the window length is adjusted according to the change in step frequency. The adaptive dual window approach is shown to successfully suppress the effects of vibration and waist shaking, thereby improving the step detection accuracy. The effectiveness of this method is demonstrated through step detection experiments and pedestrian navigation positioning experiments respectively. The step detection error rate was found to be less than 0·15% in repeated experiments consisting of 345 steps, while the longer (about 1·3 km) pedestrian navigation experiments demonstrated typical positioning error was around 0·67% of the distance travelled.

[1]  Yunseok Chang,et al.  Adaptive Step Detection Algorithm for Wireless Smart Step Counter , 2013, 2013 International Conference on Information Science and Applications (ICISA).

[2]  Valérie Renaudin,et al.  Motion Mode Recognition and Step Detection Algorithms for Mobile Phone Users , 2013, Sensors.

[3]  Corina Kim Schindhelm,et al.  Activity recognition and step detection with smartphones: Towards terminal based indoor positioning system , 2012, 2012 IEEE 23rd International Symposium on Personal, Indoor and Mobile Radio Communications - (PIMRC).

[4]  K. Tumkur,et al.  Modeling Human Walking for Step Detection and Stride Determination by 3-Axis Accelerometer Readings in Pedometer , 2012, 2012 Fourth International Conference on Computational Intelligence, Modelling and Simulation.

[5]  Kun-Chan Lan,et al.  Using simple harmonic motion to estimate walking distance for waist-mounted PDR , 2012, 2012 IEEE Wireless Communications and Networking Conference (WCNC).

[6]  K. Abdulrahim,et al.  Using Constraints for Shoe Mounted Indoor Pedestrian Navigation , 2011, Journal of Navigation.

[7]  Fernando Seco Granja,et al.  PDR with a Foot-Mounted IMU and Ramp Detection , 2011, Sensors.

[8]  Chris Hide,et al.  Aiding Low Cost Inertial Navigation with Building Heading for Pedestrian Navigation , 2011, Journal of Navigation.

[9]  Carsten Isert,et al.  Self-contained indoor positioning on off-the-shelf mobile devices , 2010, 2010 International Conference on Indoor Positioning and Indoor Navigation.

[10]  Lucila Patino-Studencki,et al.  Comparison and evaluation of acceleration based step length estimators for handheld devices , 2010, 2010 International Conference on Indoor Positioning and Indoor Navigation.

[11]  S. H. Shin,et al.  Pedestrian dead reckoning system with phone location awareness algorithm , 2010, IEEE/ION Position, Location and Navigation Symposium.

[12]  Fernando Seco Granja,et al.  Indoor pedestrian navigation using an INS/EKF framework for yaw drift reduction and a foot-mounted IMU , 2010, 2010 7th Workshop on Positioning, Navigation and Communication.

[13]  F. Seco,et al.  A comparison of Pedestrian Dead-Reckoning algorithms using a low-cost MEMS IMU , 2009, 2009 IEEE International Symposium on Intelligent Signal Processing.

[14]  J.W. Kim,et al.  Adaptive Step Length Estimation Algorithm Using Low-Cost MEMS Inertial Sensors , 2007, 2007 IEEE Sensors Applications Symposium.

[15]  Chan Gook Park,et al.  MEMS Based Pedestrian Navigation System , 2005 .

[16]  Helena Leppäkoski,et al.  Error Analysis of Step Length Estimation in Pedestrian Dead Reckoning , 2002 .

[17]  Jukka Saarinen,et al.  MEMS-IMU Based Pedestrian Navigator for Handheld Devices , 2001 .

[18]  Kenji Mase,et al.  Recognition of walking behaviors for pedestrian navigation , 2001, Proceedings of the 2001 IEEE International Conference on Control Applications (CCA'01) (Cat. No.01CH37204).

[19]  R. Jirawimut,et al.  A method for dead reckoning parameter correction in pedestrian navigation system , 2001, IMTC 2001. Proceedings of the 18th IEEE Instrumentation and Measurement Technology Conference. Rediscovering Measurement in the Age of Informatics (Cat. No.01CH 37188).

[20]  Quentin Ladetto,et al.  On foot navigation: continuous step calibration using both complementary recursive prediction and adaptive Kalman filtering , 2000 .

[21]  Fernando Seco Granja,et al.  Accurate Pedestrian Indoor Navigation by Tightly Coupling Foot-Mounted IMU and RFID Measurements , 2012, IEEE Transactions on Instrumentation and Measurement.

[22]  Qing-Hua Huang,et al.  An optical coherence tomography (OCT)-based air jet indentation system for measuring the mechanical properties of soft tissues , 2009, Measurement science & technology.

[23]  Weifeng Tian,et al.  Activity classification and dead reckoning for pedestrian navigation with wearable sensors , 2008 .

[24]  H. Weinberg Using the ADXL202 in Pedometer and Personal Navigation Applications , 2002 .