Simulation of the transient response of heat driven refrigerators with continuous temperature control

Abstract A theoretical and experimental study is presented and a mathematical model is introduced for a heat driven refrigeration system operating with continuous temperature control. The model consists of a refrigerated space, an absorption refrigerator, operating irreversibly, a temperature sensor and a reference signal, and a power law control action. The steady-state behavior of the absorption refrigerator model is validated by direct comparison between theoretical results and experimental data. The model is then used to identify an optimal thermal conductance allocation, for a fixed total thermal conductance inventory, such that the refrigeration rate is maximized and the `pull-down' time is minimized. A simulation of the system operating in a transient mode is carried out to show that closed-loop operation results in a large reduction of fuel consumption, with respect to the `on–off' operation. Appropriate dimensionless groups are identified and the generalized results reported in charts using dimensionless variables.

[1]  A. Bejan Theory of heat transfer-irreversible power plants , 1988 .

[2]  Horacio Perez-Blanco Conceptual design of a high-efficiency absorption cooling cycle , 1993 .

[3]  A. L Stolk New possibilities for absorption refrigeration machines for energy saving , 1980 .

[4]  Roberto Best,et al.  Thermodynamic design data for absorption heat pump systems operating on water-carrol. Part II: Heating , 1995 .

[5]  M. Sokolov,et al.  Optimal coupling and feasibility of a solar-powered year-round ejector air conditioner , 1993 .

[6]  J. Vargas,et al.  Simulation in transient regime of a heat pump with closed-loop and on-off control , 1995 .

[7]  N. E. Wijeysundera Performance limits of absorption cycles with external heat-transfer irreversibilities , 1996 .

[8]  A. Bejan,et al.  Optimal allocation of a heat-exchanger inventory in heat driven refrigerators , 1995 .

[9]  F. A. Holland,et al.  A study of the operating parameters in a water‐lithium bromide absorption cooler , 1986 .

[10]  J. Douglas Faires,et al.  Numerical Analysis , 1981 .

[11]  Adrian Bejan,et al.  Thermodynamic Optimization of Solar-Driven Refrigerators , 1996 .

[12]  S Ayyash,et al.  Performance results of solar absorption cooling installation , 1985 .

[13]  Benjamin C. Kuo,et al.  AUTOMATIC CONTROL SYSTEMS , 1962, Universum:Technical sciences.

[14]  Reinhard Radermacher,et al.  Part-load performance characteristics of residential absorption chillers and heat pump , 1984 .

[15]  S Ayyash,et al.  Solar absorption cooling effect on operational parameters on power saving , 1982 .

[16]  Adrian Bejan,et al.  Theory of heat transfer-irreversible refrigeration plants , 1989 .