Background Tissue-engineered heart valve leaflets are a promising way to overcome the inherent limitations of current prosthetic valves. The aim of this study was to compare the biological responses of an autologous cell seeded scaffold and an acellular scaffold implanted in the pulmonary valve leaflet in the same animal. Methods Myofibroblasts and endothelial cells were isolated and cultured from an ovine artery. A synthetic biodegradable scaffold consisting of polyglycolic acid and polylactic acid was initially seeded with the myofibroblasts, then coated with endothelial cells. Cells were seeded using a medium containing collagen and cultured. A tissue-engineered construct and a plain scaffold were implanted as double pulmonary valve leaflet replacement in the same animal in an ovine model (n=3). Additionally, the tissue-engineered construct (n=2) and the plain scaffold (n=2) were implanted as single valve leaflet replacements for long-term analysis. After sacrifice, the implanted valve leaflet tissues were retrieved, analyzed visually and using light microscopy. Results Three animals that underwent replacement of two valve leaflets with a tissue-engineered construct and a plain scaffold, survived only a short-time (12, 24, 36 hours). The death was attributed to heart failure caused by severe pulmonary insufficiency. Animals that underwent single valve leaflet replacement survived longer and were electively sacrificed at 6 and 9 weeks after operation. The analysis of the leaflets from the short-term survivors showed that the tissue-engineered constructs contained less fibrins and protein exudates than the plain scaffold. In contrast, leaflets obtained from animals surviving 6 and 9 weeks showed similar well organized granulation tissues in the tissue-engineered constructs and the plain scaffolds. Conclusion This animal experiment demonstrates that in the early phase of implantation, the tissue-engineered construct shows a better biological response in terms of antithrombogenicity than the plain scaffold, although both of them have similar results in the later reparative phase.
[1]
F J Schoen,et al.
Tissue-engineered valved conduits in the pulmonary circulation.
,
2000,
The Journal of thoracic and cardiovascular surgery.
[2]
C K Breuer,et al.
Tissue-engineered heart valves. Autologous valve leaflet replacement study in a lamb model.
,
1996,
Circulation.
[3]
A Haverich,et al.
Tissue engineering of heart valves--human endothelial cell seeding of detergent acellularized porcine valves.
,
1998,
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.
[4]
R Langer,et al.
Tissue-engineered heart valve leaflets: does cell origin affect outcome?
,
1997,
Circulation.
[5]
C K Breuer,et al.
Tissue engineering heart valves: valve leaflet replacement study in a lamb model.
,
1995,
The Annals of thoracic surgery.
[6]
R Langer,et al.
Creation of viable pulmonary artery autografts through tissue engineering.
,
1998,
The Journal of thoracic and cardiovascular surgery.
[7]
Y. Jo,et al.
Tissue-Engineered Heart Valve Leaflets: An Effective Method for Seeding Autologous Cells on Scaffolds
,
2000,
The International journal of artificial organs.
[8]
C K Breuer,et al.
Tissue engineering lamb heart valve leaflets
,
1996,
Biotechnology and bioengineering.
[9]
M A Moses,et al.
Tissue engineering of autologous aorta using a new biodegradable polymer.
,
1999,
The Annals of thoracic surgery.
[10]
R. Langer,et al.
Degradation, Structure and Properties of Fibrous Nonwoven Poly(Glycolic Acid) Scaffolds for Tissue Engineering
,
1995
.