Design and implementation of algorithms for focus automation in digital imaging time-lapse microscopy.

BACKGROUND Digital time-lapse microscopy using Nomarski-DIC requires that an autofocusing system adapt to changes in cell shape, size, and position while contending with drift, noise, and hysteresis in the microscope and imager. We have designed and implemented an autofocusing system that tracks subjects under dynamic conditions and maintains focus within a threshold of discriminability. METHODS With the use of proven and novel algorithms for autofocusing in Nomarski, we performed "virtual" experiments on recorded image stacks to simulate drift and sudden displacements and test the search algorithm response. RESULTS We found that combining a simple [1, -1] contrast function with an adaptive "warmer-colder" focusing algorithm yields a reasonable compromise between focusing precision and noise tolerance. This method was implemented to record growth kinetics of yeast cells in single and multiple fields of view over several hours. CONCLUSIONS We have implemented a robust digital autofocus that maintains focus on optically complex samples imaged at high resolution. The tolerance of this system of drift and vibration suggests that it is a practical system for time-lapse imaging in many biological applications.

[1]  J. Price,et al.  Comparison of phase-contrast and fluorescence digital autofocus for scanning microscopy. , 1994, Cytometry.

[2]  H. Netten,et al.  Autofocusing in microscopy based on the OTF and sampling , 1994 .

[3]  B H Mayall,et al.  Focus-assist device for a flying-spot microscope. , 1973, IEEE transactions on bio-medical engineering.

[4]  K Cook,et al.  Comparison of autofocus methods for automated microscopy. , 1991, Cytometry.

[5]  T R Bürglin A two‐channel four‐dimensional image recording and viewing system with automatic drift correction , 2000, Journal of microscopy.

[6]  W Böcker,et al.  A fast autofocus unit for fluorescence microscopy. , 1997, Physics in medicine and biology.

[7]  T. Cornsweet,et al.  The staircrase-method in psychophysics. , 1962, The American journal of psychology.

[8]  S. L. Ellenberger Influence of defocus on measurements in microscope images , 2000 .

[9]  M. Mendelsohn,et al.  Computer-oriented analysis of human chromosomes. 3. Focus. , 1972, Computers in biology and medicine.

[10]  J. Kiefer,et al.  Sequential minimax search for a maximum , 1953 .

[11]  L. Hartwell,et al.  The RAD9 gene controls the cell cycle response to DNA damage in Saccharomyces cerevisiae. , 1988, Science.

[12]  D. K. Green,et al.  Automatic Focusing of a Computer-Controlled Microscope , 1975, IEEE Transactions on Biomedical Engineering.

[13]  I T Young,et al.  A comparison of different focus functions for use in autofocus algorithms. , 1985, Cytometry.

[14]  C. Ortiz de Solórzano,et al.  Evaluation of autofocus functions in molecular cytogenetic analysis , 1997, Journal of microscopy.

[15]  A W Smeulders,et al.  Robust autofocusing in microscopy. , 2000, Cytometry.