Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study

Background: As breast tissue expanders consist of metallic materials in the needle guard and ferromagnetic injection port, irradiation can produce radioactivation.Materials and Methods: A CPX4 (Mentor Worldwide LLD) breast tissue expander was exposed using the Versa HD (Elekta) linear accelerator. Two photon energies of 6 and 10 MV-flattening filter free (FFF) beams with 5,000 monitor units (MU) were irradiated to identify the types of radiation. Furthermore, 300 MU with 10 MV-FFF beam was exposed to the CPX4 breast tissue expander by varying the machine dose rates (MDRs) 600, 1,200, and 2,200 MU/ min. To assess the instantaneous dose rates (IDRs) solely from the CPX4, a tissue expander was placed outside the treatment room after beam irradiation, and a portable radioisotope identification device was used to identify the types of radiation and measure IDR.Results and Discussion: After 5,000 MU delivery to the CPX4 breast tissue expander, the energy spectrum whose peak energy of 511 keV was found with 10 MV-FFF, while there was no resultant one with 6 MV-FFF. The time of each measurement was 1 minute, and the mean IDRs from the 10 MV-FFF were 0.407, 0.231, and 0.180 μSv/hr for the three successive measurements. Following 10 MV-FFF beam irradiation with 300 MU indicated around the background level from the first measurement regardless of MDRs.Conclusion: As each institute room entry time protocol varies according to the working hours and occupational doses, we suggest an addition of 1 minute from the institutes’ own room entry time protocol in patients with CPX4 tissue expander and the case of radiotherapy vaults equipped with a maximum energy of 10 MV photon beams.

[1]  Y. Lim Recent Trend of Occupational Exposure to Ionizing Radiation in Korea, 2015–2019 , 2022, Journal of Radiation Protection and Research.

[2]  Dong Wook Kim,et al.  Measurements of Neutron Activation and Dose Rate Induced by High-Energy Medical Linear Accelerator , 2021, Progress in Medical Physics.

[3]  Dong Wook Kim,et al.  Current status of disposal and measurement analysis of radioactive components in linear accelerators in Korea , 2021, Nuclear Engineering and Technology.

[4]  Hyun Soo Shin,et al.  Inter-institutional Variation in Intensity-modulated Radiotherapy for Breast Cancer in Korea (KROG 19-01) , 2021, AntiCancer Research.

[5]  J. Canady,et al.  Safety of CPX4 Breast Tissue Expanders in Primary Reconstruction Patients , 2021, Plastic and reconstructive surgery. Global open.

[6]  Liang-Chih Liu,et al.  Automated Hypofractionated IMRT treatment planning for early-stage breast Cancer , 2020, Radiation Oncology.

[7]  S. Ahn,et al.  Patterns of Practice in Radiotherapy for Breast Cancer in Korea , 2018, Journal of breast cancer.

[8]  Rui Zhang,et al.  Modeling of the metallic port in breast tissue expanders for photon radiotherapy , 2018, Journal of applied clinical medical physics.

[9]  Shogo Hatanaka,et al.  Determination of the appropriate physical density of internal metallic ports in temporary tissue expanders for the treatment planning of post-mastectomy radiation therapy , 2018, Journal of radiation research.

[10]  D. Lee,et al.  Assessment of human exposure doses received by activation of medical linear accelerator components , 2017 .

[11]  E. Raposio,et al.  Tissue expansion for breast reconstruction: Methods and techniques , 2017, Annals of medicine and surgery.

[12]  S. Cilla,et al.  Intensity modulated radiation therapy for breast cancer: current perspectives , 2017, Breast cancer.

[13]  Ali Diba,et al.  Determination of room entry times for radiation therapists after routine 15 MV photon treatments , 2015 .

[14]  S. Suriyapee,et al.  Evaluation of equivalent dose from neutrons and activation products from a 15-MV X-ray LINAC , 2015, Journal of radiation research.

[15]  M Saiful Huq,et al.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71. , 2014, Medical physics.

[16]  U. Schneider,et al.  Measurement of skin and target dose in post-mastectomy radiotherapy using 4 and 6 MV photon beams , 2013, Radiation oncology.

[17]  U. Schneider,et al.  Measurement of skin and target dose in post-mastectomy radiotherapy using 4 and 6 MV photon beams , 2013, Radiation Oncology.

[18]  R. Zellars,et al.  Dosimetric Impact and 3D Nondeformable Modeling of Metallic Breast Expander Ports During Postmastectomy Radiation Therapy , 2013 .

[19]  V. Dixit,et al.  Tissue expansion: Concepts, techniques and unfavourable results , 2013, Indian journal of plastic surgery : official publication of the Association of Plastic Surgeons of India.

[20]  O. Riesterer,et al.  Breast reconstruction and post-mastectomy radiation practice , 2013, Radiation oncology.

[21]  A. Losken,et al.  Impact of internal metallic ports in temporary tissue expanders on postmastectomy radiation dose distribution. , 2013, International journal of radiation oncology, biology, physics.

[22]  S. Cardoso,et al.  Influence of the Presence of Tissue Expanders on Energy Deposition for Post-Mastectomy Radiotherapy , 2013, PloS one.

[23]  P. White,et al.  Evaluation of Optimum Room Entry Times for Radiation Therapists after High Energy Whole Pelvic Photon Treatments , 2012, Journal of occupational health.

[24]  M. Zambetti,et al.  Outcome of Different Timings of Radiotherapy in Implant-Based Breast Reconstructions , 2011, Plastic and reconstructive surgery.

[25]  P. Karaiskos,et al.  Dose perturbation in the radiotherapy of breast cancer patients implanted with the Magna‐Site: a Monte Carlo study , 2011, Journal of applied clinical medical physics.

[26]  B. Poppe,et al.  COMPARISON OF ACTIVATION PRODUCTS AND INDUCED DOSE RATES IN DIFFERENT HIGH-ENERGY MEDICAL LINEAR ACCELERATORS , 2008, Health physics.

[27]  Björn Poppe,et al.  Activation processes in a medical linear accelerator and spatial distribution of activation products , 2006, Physics in medicine and biology.

[28]  P. Cordeiro,et al.  Do metallic ports in tissue expanders affect postmastectomy radiation delivery? , 2006, International journal of radiation oncology, biology, physics.

[29]  P. Cordeiro,et al.  Unilateral Postoperative Chest Wall Radiotherapy in Bilateral Tissue Expander/Implant Reconstruction Patients: A Prospective Outcomes Analysis , 2005, Plastic and reconstructive surgery.

[30]  J. Valentin,et al.  Protecting people against radiation exposure in the event of a radiological attack , 2005, Annals of the ICRP.

[31]  K. Griffith,et al.  Dosimetry around metallic ports in tissue expanders in patients receiving postmastectomy radiation therapy: an ex vivo evaluation. , 2004, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[32]  A. Niemierko,et al.  Radiotherapy and breast reconstruction: complications and cosmesis with TRAM versus tissue expander/implant. , 2002, International journal of radiation oncology, biology, physics.

[33]  M. Griem Neutron Contamination From Medical Electron Accelerators , 1985 .

[34]  K. Mohammadi,et al.  Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations , 2014, Journal of medical physics.

[35]  Qu Liang,et al.  The United Nations Scientific Committee on the Effects of Atomic Radiation , 1965, Nature.