[Assessment of measured respirable dust sampler penetration and the sampling convention for work environment measurement].

The relationship between dust size and penetration for a static horizontal elutriator (Sibata C-30) was measured in calm air. The elutriator as a low-volume air sampler is widely used as a dust size classifier in work environment measurements. The actual penetrations were compared with the theoretical models of the sampler and with sampling convention for respirable dust in work environment measurement. The sampling convention was recently introduced into the Japanese standard for work environment measurement and is based on the ISO 7708 respirable dust convention. The bias of sampled masses from the respirable dust was calculated for two flow rates of the sampler, i.e., 50% cut sizes of 4 microm and 5 microm, from measured penetration curves. The bias of the sampler was overestimated in the 5 microm, 50% cut condition and underestimated in the 4 microm, 50% cut condition for most workplace sampling situations.

[1]  Jing-Shiang Hwang,et al.  Laboratory Performance Comparison of Respirable Samplers , 1999 .

[2]  Wolfgang Koch,et al.  Design and Performance of a New Personal Aerosol Monitor , 1999 .

[3]  Paul A. Baron,et al.  Personal Aerosol Sampler Design: A Review , 1998 .

[4]  M. Gautam,et al.  Performance of a respirable multi-inlet cyclone sampler , 1997 .

[5]  L. C. Kenny,et al.  THE PERFORMANCE OF RESPIRABLE DUST SAMPLERS: SAMPLER BIAS, PRECISION AND INACCURACY , 1992 .

[6]  G. Lidén,et al.  Comparison of measured respirable dust sampler penetration curves with sampling conventions. , 1991, The Annals of occupational hygiene.

[7]  P. Hewett Limitations in the Use of Particle Size-Selective Sampling Criteria in Occupational Epidemiology , 1991 .

[8]  J H Vincent,et al.  Entry characteristics of practical workplace aerosol samplers in relation to the ISO recommendations. , 1990, The Annals of occupational hygiene.

[9]  T. Carsey LISA: a new aerosol generation system for sampler evaluation. , 1987, American Industrial Hygiene Association journal.

[10]  T. Ogden,et al.  An inhalable-dust sampler, for measuring the hazard from total airborne particulate. , 1978, The Annals of occupational hygiene.

[11]  Ogden Tl,et al.  The human head as a dust sampler. , 1975, Inhaled particles.

[12]  Benjamin Y. H. Liu,et al.  Generation of monodisperse aerosol standards , 1973 .

[13]  P. Görner,et al.  Study of fifteen respirable aerosol samplers used in occupational hygiene. , 2001, The Annals of occupational hygiene.

[14]  T. Myojo A Simple Method to Determine the Length Distribution of Fibrous Aerosols , 1999 .

[15]  L. Kenny Developments in workplace aerosol sampling. A review. , 1996, The Analyst.

[16]  L. C. Kenny,et al.  A technique for assessing size-selective dust samplers using the APS and polydisperse test aerosols , 1991 .

[17]  S C Soderholm,et al.  Proposed international conventions for particle size-selective sampling. , 1989, The Annals of occupational hygiene.

[18]  J. Heyder,et al.  Deposition of particles in the human respiratory tract in the size range 0.005–15 μm , 1986 .

[19]  Paul A. Baron,et al.  Calibration and Use of the Aerodynamic Particle Sizer (APS 3300) , 1986 .

[20]  J H Vincent,et al.  Applications of blunt sampler theory to the definition and measurement of inhalable dust. , 1982, The Annals of occupational hygiene.

[21]  L Armbruster,et al.  Investigations into defining inhalable dust. , 1982, The Annals of occupational hygiene.