Characterization and optimization of microelectrode arrays for in vivo nerve signal recording and stimulation.

Revealing the complex signal-processing mechanisms and interconnection patterns of the nervous system has long been an intriguing puzzle. As a contribution to its understanding the optimization of the impedance behavior of implantable electrode arrays with via holes is discussed here. Peripheral axons will regenerate through these holes allowing for simultaneous nerve stimulation and signal recording. This approach is part of the ESPRIT project INTER and may eventually lead to devices driving sensory motor prosthesis with closed loop control. In the first set of experiments, micromachined platinum electrode arrays were prepared, characterized and optimized for nerve signal recording. The results of these studies are based on impedance spectroscopy and microscopic techniques. Equivalent circuits were modeled describing formally the electrical response behavior with ohmic resistances between 500 omega and 10 k omega. To attain low impedances for all electrodes on the INTER device, platinum from H2PtCl6 was electrodeposited, and sputter technology as well as electrochemical deposition from H2IrCl6 solution were used to produce thin iridium films. For the former, a lift-off process was established at one of the institutes to generate electrode structures with a line width of 5 microns. As a result in all three cases the electrodes showed almost constant impedances over the entire frequency range (10 Hz-1 kHz), which is relevant for nerve signal recording. In the second set of experiments, electrodes were optimized to allow for nerve stimulation. For this purpose, the charge delivery capacity (CDC) had to be increased and the impedance had to be decreased. Iridium oxide is the material of choice, because its CDC is much higher than the CDC of platinum at 75 microC/cm2 (Ziaie et al., 1991, IEEE Sensors & Actuators Transducers, 6, 124-127). A significant increase of the electrochemically active surface of the electrode structures could be observed by measuring the surface roughness. In first experiments, an activated iridium oxide film was formed with cyclic voltammetry and was evaluated using scanning force microscopy and impedance spectroscopy. The evaluation of the cyclic voltammograms showed a CDC up to 400 mC/cm2 for sputter deposited and oxidatively treated iridium films. Further investigations are directed towards increasing the stability of the iridium oxide electrodes with regard to long-term implants. Parallel experiments aim at the controlled axon adhesion without changing the impedance behavior of the described electrodes.

[1]  K. Najafi,et al.  A high-current IrO/sub x/ thin-film neuromuscular microstimulator , 1991, TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers.

[2]  Thomas M. McKenna,et al.  Enabling Technologies for Cultured Neural Networks , 1994 .

[3]  G. Beni,et al.  Anodic iridium oxide films: A new electrochromic , 1979, IEEE Transactions on Electron Devices.

[4]  J. Cox,et al.  Characterization of oxide films electrochemically deposited from solutions of palladium chloride and sodium hexachloroiridate , 1992 .

[5]  R. Kötz,et al.  Anodic Iridium Oxide Films XPS‐Studies of Oxidation State Changes and , 1984 .

[6]  L. Burke,et al.  A voltammetric investigation of the charge storage reactions of hydrous iridium oxide layers , 1984 .

[7]  P. Pickup,et al.  The Influence of the Aqueous Growth Medium on the Growth Rate, Composition, and Structure of Hydrous Iridium Oxide Films , 1988 .

[8]  B. Conway,et al.  Electron Microscopy Study of Formation of Thick Oxide Films on Ir and Ru Electrodes , 1984 .

[9]  F. Endres,et al.  Cyclic voltammetry of polyethylene stabilized hydrogen molybdenum bronzes , 1996 .

[10]  Wouter Olthuis,et al.  pH sensor properties of electrochemically grown iridium oxide , 1990 .

[11]  S. Gottesfeld,et al.  Electrochromism in Anodic Iridium Oxide Films II . pH Effects on Corrosion Stability and the Mechanism of Coloration and Bleaching , 1979 .

[12]  M. Vuković,et al.  Electrochemical behaviour of an electrodeposited iridium electrode in acid solution , 1990 .

[13]  E. Valderrama,et al.  Peripheral nerve regeneration through microelectrode arrays based on silicon technology. , 1996, Restorative neurology and neuroscience.

[14]  D. Michell,et al.  Analysis of the anodic oxygen layer on iridium by X-ray emission, electron diffraction and electron microscopy , 1977 .