Operation of multiple inverters in grid-connected large-size photovoltaic installations

This paper deals with the characterisation of the waveform distortion in the operation of grid-connected photovoltaic (PV) inverters. The PV system assessment is based on experimental results. The data elaborated are taken from the measurements gathered at the terminals of individual PV inverters and at the point of common coupling (PCC) between the PV plant and the grid. For the connection of multiple PV inverters to the grid, the peculiar characteristics of the PV plants, allowing for their distinction with respect to the harmonic loads addressed in the literature, are identified and discussed. Specific harmonic and interharmonic models are constructed on the basis of experimental data, indicating the different ways in which low-order and high- order harmonics sum up at the PCC.

[1]  D.G. Infield,et al.  Power quality from multiple grid-connected single-phase inverters , 2004, IEEE Transactions on Power Delivery.

[2]  A. Jäger-Waldau,et al.  Photovoltaics and renewable energies in Europe , 2007 .

[3]  David Infield,et al.  Impact of widespread photovoltaics generation on distribution systems , 2007 .

[4]  J. David Tàbara,et al.  Harmonization of renewable electricity feed-in laws in the European Union , 2007 .

[5]  Achim Woyte,et al.  Investigating performance, reliability and safety parameters of photovoltaic module inverter: Test results and compliances with the standards , 2006 .

[6]  Gianfranco Chicco,et al.  Experimental assessment of the waveform distortion in grid-connected photovoltaic installations , 2009 .

[7]  G. Chicco,et al.  Performance of Grid-Connected Photovoltaic Systems in Fixed and Sun-Tracking Configurations , 2007, 2007 IEEE Lausanne Power Tech.

[8]  J. Schlabbach,et al.  Voltage Quality in Electrical Power Systems , 2001 .

[9]  Niccolò Aste,et al.  Evaluation of energy policies for promotion and dissemination of photovoltaic technology in Italy , 2007 .

[10]  P.J.M. Heskes,et al.  Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.

[11]  Pablo Sanchis,et al.  On the testing, characterization, and evaluation of PV inverters and dynamic MPPT performance under real varying operating conditions , 2007 .

[12]  J. Schlabbach,et al.  Prediction of harmonic currents of PV-inverters using measured solar radiation data , 2006, MELECON 2006 - 2006 IEEE Mediterranean Electrotechnical Conference.

[13]  S. M. Halpin,et al.  Determination of Allowable Penetration Levels of Distributed Generation Resources Based on Harmonic Limit Consideration , 2002, IEEE Power Engineering Review.

[14]  Juan Carlos Balda,et al.  A PV dispersed generator: a power quality analysis within the IEEE 519 , 2003 .

[15]  G. Chicco,et al.  Experimental evaluation of the performance of grid-connected photovoltaic systems , 2004, Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521).

[16]  W. G. Sherman Summation of harmonics with random phase angles , 1972 .