The effect of multimicrophone noise reduction systems on sound source localization by users of binaural hearing aids.

This paper evaluates the influence of three multimicrophone noise reduction algorithms on the ability to localize sound sources. Two recently developed noise reduction techniques for binaural hearing aids were evaluated, namely, the binaural multichannel Wiener filter (MWF) and the binaural multichannel Wiener filter with partial noise estimate (MWF-N), together with a dual-monaural adaptive directional microphone (ADM), which is a widely used noise reduction approach in commercial hearing aids. The influence of the different algorithms on perceived sound source localization and their noise reduction performance was evaluated. It is shown that noise reduction algorithms can have a large influence on localization and that (a) the ADM only preserves localization in the forward direction over azimuths where limited or no noise reduction is obtained; (b) the MWF preserves localization of the target speech component but may distort localization of the noise component. The latter is dependent on signal-to-noise ratio and masking effects; (c) the MWF-N enables correct localization of both the speech and the noise components; (d) the statistical Wiener filter approach introduces a better combination of sound source localization and noise reduction performance than the ADM approach.

[1]  Fa-Long Luo,et al.  Adaptive null-forming scheme in digital hearing aids , 2002, IEEE Trans. Signal Process..

[2]  E. Zwicker,et al.  Subdivision of the audible frequency range into critical bands , 1961 .

[3]  Marc Moonen,et al.  Spatially pre-processed speech distortion weighted multi-channel Wiener filtering for noise reduction , 2003, Signal Process..

[4]  R Plomp,et al.  The effect of head-induced interaural time and level differences on speech intelligibility in noise. , 1987, The Journal of the Acoustical Society of America.

[5]  William M. Hartmann,et al.  How we localize sound , 1999 .

[6]  Richard Van Hoesel,et al.  Sound-Direction Identification, Interaural Time Delay Discrimination, and Speech Intelligibility Advantages in Noise for a Bilateral Cochlear Implant User , 2002, Ear and hearing.

[7]  Marc Moonen,et al.  GSVD-based optimal filtering for single and multimicrophone speech enhancement , 2002, IEEE Trans. Signal Process..

[8]  Walter Kellermann,et al.  Multi-Channel Source Separation Preserving Spatial Information , 2007, 2007 IEEE International Conference on Acoustics, Speech and Signal Processing - ICASSP '07.

[9]  Marc Moonen,et al.  Binaural Multi-Channel Wiener Filtering for Hearing Aids: Preserving Interaural Time and Level Differences , 2006, 2006 IEEE International Conference on Acoustics Speech and Signal Processing Proceedings.

[10]  M. Moonen,et al.  Distortion of interaural time cues by directional noise reduction systems in modern digital hearing aids , 2005, IEEE Workshop on Applications of Signal Processing to Audio and Acoustics, 2005..

[11]  J. Blauert Spatial Hearing: The Psychophysics of Human Sound Localization , 1983 .

[12]  C. Lorenzi,et al.  Sound localization in noise in normal-hearing listeners. , 1997, The Journal of the Acoustical Society of America.

[13]  F. Wightman,et al.  The dominant role of low-frequency interaural time differences in sound localization. , 1992, The Journal of the Acoustical Society of America.

[14]  Patrick M. Zurek,et al.  Microphone-array hearing aids with binaural output. II. A two-microphone adaptive system , 1997, IEEE Trans. Speech Audio Process..

[15]  Volker Hohmann,et al.  Strategy-selective noise reduction for binaural digital hearing aids , 2003, Speech Commun..

[16]  Gitte Keidser,et al.  The effect of multi-channel wide dynamic range compression, noise reduction, and the directional microphone on horizontal localization performance in hearing aid wearers , 2006, International journal of audiology.

[17]  S. Haykin,et al.  Adaptive Filter Theory , 1986 .

[18]  Marc Moonen,et al.  Binaural Noise Reduction Algorithms for Hearing Aids That Preserve Interaural Time Delay Cues , 2007, IEEE Transactions on Signal Processing.

[19]  Marc Moonen,et al.  THEORETICAL ANALYSIS OF BINAURAL CUE PRESERVATION USING MULTI-CHANNEL WIENER FILTERING AND INTERAURAL TRANSFER FUNCTIONS , 2006 .

[20]  Patrick M. Zurek,et al.  Microphone-array hearing aids with binaural output .I. Fixed-processing systems , 1997, IEEE Trans. Speech Audio Process..

[21]  Denis Byrne,et al.  Open Earmold Fittings for Improving Aided Auditory Localization for Sensorineural Hearing Losses with Good High‐Frequency Hearing , 1998, Ear and hearing.

[22]  A. M. Mimpen,et al.  Improving the reliability of testing the speech reception threshold for sentences. , 1979, Audiology : official organ of the International Society of Audiology.

[23]  Marc Moonen,et al.  Binaural Cue Preservation for Hearing Aids using an Interaural Transfer Function Multichannel Wiener Filter , 2007, 2007 IEEE International Conference on Acoustics, Speech and Signal Processing - ICASSP '07.

[24]  Marc Moonen,et al.  Horizontal localization with bilateral hearing aids: without is better than with. , 2006, The Journal of the Acoustical Society of America.

[25]  Marc Moonen,et al.  Noise Reduction Results of an Adaptive Filtering Technique for Dual-Microphone Behind-the-Ear Hearing Aids , 2004, Ear and hearing.

[26]  R. Plomp,et al.  Binaural speech intelligibility in noise for hearing-impaired listeners. , 1989, The Journal of the Acoustical Society of America.

[27]  Patrick M. Zurek,et al.  Two-Microphone Adaptive Array Hearing Aids With Monaural And Binaural Outputs , 2000 .

[28]  W Noble,et al.  Improvement in aided sound localization with open earmolds: observations in people with high-frequency hearing loss. , 1998, Journal of the American Academy of Audiology.

[29]  Jian-Kang Zhang,et al.  A fractionally spaced blind equalizer based on linear programming , 2002, IEEE Trans. Signal Process..

[30]  W Noble,et al.  A comparison of different binaural hearing aid systems for sound localization in the horizontal and vertical planes. , 1990, British journal of audiology.

[31]  T Houtgast,et al.  Method for the selection of sentence materials for efficient measurement of the speech reception threshold. , 1999, The Journal of the Acoustical Society of America.