Evaluation of carbon nanotube probes in critical dimension atomic force microscopes

Abstract. The decreasing size of semiconductor features and the increasing structural complexity of advanced devices have placed continuously greater demands on manufacturing metrology, arising both from the measurement challenges of smaller feature sizes and the growing requirement to characterize structures in more than just a single critical dimension. For scanning electron microscopy, this has resulted in increasing sophistication of imaging models. For critical dimension atomic force microscopes (CD-AFMs), this has resulted in the need for smaller and more complex tips. Carbon nanotube (CNT) tips have thus been the focus of much interest and effort by a number of researchers. However, there have been significant issues surrounding both the manufacture and use of CNT tips. Specifically, the growth or attachment of CNTs to AFM cantilevers has been a challenge to the fabrication of CNT tips, and the flexibility and resultant bending artifacts have presented challenges to using CNT tips. The Korea Research Institute for Standards and Science (KRISS) has invested considerable effort in the controlled fabrication of CNT tips and is collaborating with the National Institute of Standards and Technology on the application of CNT tips for CD-AFM. Progress by KRISS on the precise control of CNT orientation, length, and end modification, using manipulation and focused ion beam processes, has allowed us to implement ball-capped CNT tips and bent CNT tips for CD-AFM. Using two different generations of CD-AFM instruments, we have evaluated these tip types by imaging a line/space grating and a programmed line edge roughness specimen. We concluded that these CNTs are capable of scanning the profiles of these structures, including re-entrant sidewalls, but there remain important challenges to address. These challenges include tighter control of tip geometry and careful optimization of scan parameters and algorithms for using CNT tips.

[1]  Maki Tanaka,et al.  New technique to reconstruct effective 3D profile from tilt images of CD-SEM , 2004, SPIE Advanced Lithography.

[2]  Johann Foucher,et al.  Overcoming silicon limitations: new 3D-AFM carbon tips with constantly high-resolution for sub-28nm node semiconductor requirements , 2012, Advanced Lithography.

[3]  Christopher J. Raymond,et al.  Dome scatterometry for the measurement of advanced geometry semiconductor devices , 2006, SPIE Advanced Lithography.

[4]  Ndubuisi G. Orji,et al.  Scanning probe microscope dimensional metrology at NIST , 2011 .

[5]  Vladimir A. Ukraintsev,et al.  Review of reference metrology for nanotechnology: significance, challenges, and solutions , 2012 .

[6]  Chang-Soo Han,et al.  Imaging artefacts in atomic force microscopy with carbon nanotube tips , 2005 .

[7]  Y. Lee,et al.  Introduction of next-generation 3D AFM for advanced process control , 2013, Advanced Lithography.

[8]  Richard A. Allen,et al.  Metrology needs for through-silicon via fabrication , 2014 .

[9]  B. C. Park,et al.  Precision carbon nanotube tip for critical dimension measurement with atomic force microscope , 2005, SPIE Advanced Lithography.

[10]  Ndubuisi G. Orji,et al.  Distributed Force Probe Bending Model of CD-AFM Bias | NIST , 2013 .

[11]  Tsuneo Terasawa,et al.  Three-dimensional metrology with side-wall measurement using tilt-scanning operation in digital probing AFM , 2006, SPIE Advanced Lithography.

[12]  Alok Vaid,et al.  Hybrid metrology co-optimization of critical dimension scanning electron microscope and optical critical dimension , 2014 .

[13]  Ndubuisi G. Orji,et al.  Effects of lateral tip control in CD-AFM width metrology , 2014 .

[14]  Daniel F. Sunday,et al.  Evaluation of the effect of data quality on the profile uncertainty of critical dimension small angle x-ray scattering , 2016 .

[15]  Ndubuisi G. Orji,et al.  Interactions of higher order tip effects in critical dimension-AFM linewidth metrology , 2015 .

[16]  Nobuo Kochi,et al.  Three-dimensional measurement by tilting and moving objective lens in CD-SEM , 2003, SPIE Advanced Lithography.

[17]  Seiji Akita,et al.  Carbon-nanotube tips for scanning probe microscopy: Preparation by a controlled process and observation of deoxyribonucleic acid , 1999 .

[18]  Ndubuisi G. Orji,et al.  Distributed force probe bending model of critical dimension atomic force microscopy bias , 2013 .

[19]  S. Sohail H. Naqvi,et al.  Scatterometry for CD measurements of etched structures , 1996, Advanced Lithography.

[20]  Wei Chu,et al.  An image stitching method to eliminate the distortion of the sidewall in linewidth measurement , 2004, SPIE Advanced Lithography.

[21]  M. Meyyappan,et al.  Carbon nanotube tip probes: stability and lateral resolution in scanning probe microscopy and application to surface science in semiconductors , 2001 .

[22]  Yueming Hua,et al.  Three-dimensional imaging of undercut and sidewall structures by atomic force microscopy. , 2011, The Review of scientific instruments.

[23]  Ndubuisi G. Orji,et al.  Traceable calibration of a critical dimension atomic force microscope , 2011, Defense + Commercial Sensing.

[24]  H. Kumar Wickramasinghe,et al.  Method for imaging sidewalls by atomic force microscopy , 1994 .

[25]  Hui Zhou,et al.  Optimizing hybrid metrology: rigorous implementation of Bayesian and combined regression , 2015, Journal of micro/nanolithography, MEMS, and MOEMS : JM3.

[26]  Byong-Chon Park,et al.  Bending of a Carbon Nanotube in Vacuum Using a Focused Ion Beam , 2006 .

[27]  Ndubuisi G. Orji,et al.  Progress on implementation of a reference measurement system based on a critical-dimension atomic force microscope , 2007 .

[28]  Byong Chon Park,et al.  Accuracy improvement of protrusion angle of carbon nanotube tips by precision multiaxis nanomanipulator , 2005 .

[29]  Hiroshi Itoh,et al.  Atomic force microscope method for sidewall measurement through carbon nanotube probe deformation correction , 2012 .

[30]  B. C. Park,et al.  Application of carbon nanotube probes in a critical dimension atomic force microscope , 2007, SPIE Advanced Lithography.

[31]  Byong Chon Park,et al.  Ion Beam Bending of Nano Scale Materials in Free Space , 2006 .

[32]  Jun-Hyuk Choi,et al.  Carbon nanotube probes for three-dimensional critical-dimension metrology , 2006, SPIE Advanced Lithography.

[33]  H. Dai,et al.  Nanotubes as nanoprobes in scanning probe microscopy , 1996, Nature.

[34]  John S. Villarrubia,et al.  CD-SEM measurement line edge roughness test patterns for 193 nm lithography , 2003, SPIE Advanced Lithography.

[35]  Gregory A. Dahlen,et al.  Carbon nanotube AFM probes for microlithography process control , 2006, SPIE Advanced Lithography.

[36]  Martha I. Sanchez,et al.  Carbon nanotube scanning probe for surface profiling of DUV and 193-nm photoresist pattern , 2002, SPIE Advanced Lithography.

[37]  Gaoliang Dai,et al.  New developments at Physikalisch Technische Bundesanstalt in three-dimensional atomic force microscopy with tapping and torsion atomic force microscopy mode and vector approach probing strategy , 2012 .

[38]  Gregory A. Dahlen,et al.  Tip characterization and surface reconstruction of complex structures with critical dimension atomic force microscopy , 2005 .

[39]  Heather Patrick,et al.  Progress toward traceable nanoscale optical critical dimension metrology for semiconductors , 2007, SPIE Optical Engineering + Applications.

[40]  Benjamin Bunday,et al.  Assessment of critical dimension small-angle x-ray scattering measurement approaches for FinFET fabrication process monitoring , 2014 .