Arthroscopic transosseous rotator cuff repair: technical note, outcomes, and complications.

The goal of this study was to review the authors' initial experience with arthroscopic transosseous rotator cuff repair. Thirty-one patients with full-thickness rotator cuff tears underwent arthroscopic transosseous rotator cuff repair over a 15-month period. Preoperatively, demographics and subjective scores were recorded. Postoperatively, pain levels, subjective shoulder values, satisfaction scores, American Shoulder and Elbow Surgeons (ASES) scores, complications, and reoperations were noted with a minimum 2-year follow-up. The relationships between pre- and intraoperative variables and outcome scores were determined with univariate analysis. Average patient age was 56 years, and 23 patients (74%) were men. Twenty patients (65%) underwent primary rotator cuff repair, and 11 patients (35%) underwent revision repair. Average time to follow-up was 26 months. Average preoperative pain level and subjective shoulder value were 5.1 of 10 and 35%, respectively. Average postoperative scores included pain level of 0.9 of 10, subjective shoulder value of 84%, satisfaction score of 90.6 of 100, and ASES score of 86.3 of 100. There were 3 (9.7%) major and 2 (6%) minor complications. Patients undergoing revision rotator cuff repair had significantly worse outcomes (pain level, subjective shoulder value, ASES score; P<.05) compared with those undergoing primary repair, and cortical augmentation did not significantly affect outcome. Overall, outcomes after arthroscopic transosseous rotator cuff repair are good, although patients undergoing revision repair do not have the same outcomes as those undergoing primary cuff repair. The procedure is not without complications (9.7% major, 6% minor complications). Cortical augmentation may be used to supplement fixation, although it does not necessarily affect outcomes. Patients without such augmentation may be at increased risk for suture cutout through the bone.

[1]  M. Lazarus,et al.  Arthroscopic Transosseous Rotator Cuff Repair , 2015, Orthopaedic Journal of Sports Medicine.

[2]  A. Tosteson,et al.  The cost-effectiveness of single-row compared with double-row arthroscopic rotator cuff repair. , 2012, Journal of Bone and Joint Surgery. American volume.

[3]  M. Lazarus,et al.  Arthroscopic bone tunnel augmentation for rotator cuff repair. , 2012, Orthopedics.

[4]  A. Green,et al.  Initial Fixation Strength of Transosseous-Equivalent Suture Bridge Rotator Cuff Repair Is Comparable With Transosseous Repair , 2012, The American journal of sports medicine.

[5]  Chien-Lin Liu,et al.  Clinical outcome and imaging of arthroscopic single-row and double-row rotator cuff repair: a prospective randomized trial. , 2012, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[6]  R. Garofalo,et al.  Arthroscopic transosseous (anchorless) rotator cuff repair , 2012, Knee Surgery, Sports Traumatology, Arthroscopy.

[7]  A. Lädermann,et al.  Midterm outcome of arthroscopic revision repair of massive and nonmassive rotator cuff tears. , 2011, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[8]  T. Hoffelner,et al.  Arthroscopic rotator cuff repair: a biomechanical comparison of the suture-bridge technique vs. a new transosseous technique using SutureButtons(®). , 2011, Clinical biomechanics.

[9]  W. Walsh,et al.  Biomechanical evaluation of four different transosseous-equivalent/suture bridge rotator cuff repairs , 2011, Knee Surgery, Sports Traumatology, Arthroscopy.

[10]  Grant L Jones,et al.  Outcomes of single-row and double-row arthroscopic rotator cuff repair: a systematic review. , 2010, The Journal of bone and joint surgery. American volume.

[11]  K. Yamaguchi,et al.  Revision arthroscopic rotator cuff repair: repair integrity and clinical outcome. , 2010, The Journal of bone and joint surgery. American volume.

[12]  R. Tashjian,et al.  Minimal clinically important differences in ASES and simple shoulder test scores after nonoperative treatment of rotator cuff disease. , 2010, The Journal of bone and joint surgery. American volume.

[13]  B. Cole,et al.  Outcomes after Arthroscopic Revision Rotator Cuff Repair , 2010, The American journal of sports medicine.

[14]  T. Duquin Clinical Outcomes of Double-Row Versus Single-Row Rotator Cuff Repairs , 2010 .

[15]  R. Brophy,et al.  Clinical outcomes of double-row versus single-row rotator cuff repairs. , 2009, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[16]  D. Goutallier,et al.  Long-term functional and structural outcome in patients with intact repairs 1 year after open transosseous rotator cuff repair. , 2009, Journal of shoulder and elbow surgery.

[17]  Frederick A Matsen Open rotator cuff repair without acromioplasty. , 2005, The Journal of bone and joint surgery. American volume.

[18]  M. Ramsey,et al.  What's new in shoulder and elbow surgery. , 2009, The Journal of bone and joint surgery. American volume.

[19]  A. Minami,et al.  In vitro and finite element analysis of a novel rotator cuff fixation technique. , 2008, Journal of shoulder and elbow surgery.

[20]  B. Fleming,et al.  Biomechanical comparison of single-row arthroscopic rotator cuff repair technique versus transosseous repair technique. , 2008, Journal of shoulder and elbow surgery.

[21]  J. Crues,et al.  Repair Site Integrity after Arthroscopic Transosseous-Equivalent Suture-Bridge Rotator Cuff Repair , 2008, The American journal of sports medicine.

[22]  N. Zheng,et al.  Failure analysis of rotator cuff repair: a comparison of three double-row techniques. , 2008, The Journal of bone and joint surgery. American volume.

[23]  M. Baums,et al.  Biomechanical evaluation of rotator cuff repairs in a sheep model: suture anchors using arthroscopic Mason-Allen stitches compared with transosseous sutures using traditional modified Mason-Allen stitches. , 2008, Clinical biomechanics.

[24]  C. Gerber,et al.  Comparison of the subjective shoulder value and the Constant score. , 2007, Journal of shoulder and elbow surgery.

[25]  Paul B. Lewis,et al.  Arthroscopic rotator cuff repair: prospective functional outcome and repair integrity at minimum 2-year follow-up. , 2007, Journal of shoulder and elbow surgery.

[26]  B. Fleming,et al.  Initial fixation strength of massive rotator cuff tears: in vitro comparison of single-row suture anchor and transosseous tunnel constructs. , 2007, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[27]  Neal S ElAttrache,et al.  Arthroscopic rotator cuff repairs: an anatomic and biomechanical rationale for different suture-anchor repair configurations. , 2007, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[28]  Stephen S Burkhart,et al.  Arthroscopic rotator cuff repair. , 2006, The Journal of the American Academy of Orthopaedic Surgeons.

[29]  I. Lo,et al.  Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. , 2006, Journal of shoulder and elbow surgery.

[30]  R. Kvitne,et al.  Biomechanical Comparison of a Single-Row versus Double-Row Suture Anchor Technique for Rotator Cuff Repair , 2006, The American journal of sports medicine.

[31]  C. Ahmad,et al.  Tendon-Bone Interface Motion in Transosseous Suture and Suture Anchor Rotator Cuff Repair Techniques , 2005, The American journal of sports medicine.

[32]  Maxwell C. Park,et al.  Tendon-to-Bone Pressure Distributions at a Repaired Rotator Cuff Footprint Using Transosseous Suture and Suture Anchor Fixation Techniques , 2005, The American journal of sports medicine.

[33]  D. P. O'connor,et al.  Arthroscopic rotator cuff repair with and without arthroscopic subacromial decompression: a prospective, randomized study of one-year outcomes. , 2004, Journal of shoulder and elbow surgery.

[34]  I. Lo,et al.  Arthroscopic revision of failed rotator cuff repairs: technique and results. , 2004, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[35]  F. Savoie,et al.  Arthroscopic repair of large and massive rotator cuff tears. , 2003, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[36]  Russell F Warren,et al.  Supplementation of Rotator Cuff Repair with a Bioresorbable Scaffold * , 2002, The American journal of sports medicine.

[37]  F. Wilson,et al.  Arthroscopic repair of full-thickness tears of the rotator cuff: 2- to 14-year follow-up. , 2002, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[38]  S S Burkhart,et al.  Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair. , 2001, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[39]  C. Gerber,et al.  Clinical Outcome After Structural Failure of Rotator Cuff Repairs* , 2000, The Journal of bone and joint surgery. American volume.

[40]  C. Gerber,et al.  Experimental rotator cuff repair. A preliminary study. , 1999, The Journal of bone and joint surgery. American volume.

[41]  R. Debski,et al.  Strength of Fixation with Transosseous Sutures in Rotator Cuff Repair* , 1997, The Journal of bone and joint surgery. American volume.

[42]  P. Noble,et al.  Fixation strength of rotator cuff repairs with suture anchors and the transosseous suture technique. , 1996, Journal of shoulder and elbow surgery.

[43]  C Gerber,et al.  Mechanical strength of repairs of the rotator cuff. , 1994, The Journal of bone and joint surgery. British volume.