Image-based motion compensation for high-resolution extremities cone-beam CT

Purpose: Cone-beam CT (CBCT) of the extremities provides high spatial resolution, but its quantitative accuracy may be challenged by involuntary sub-mm patient motion that cannot be eliminated with simple means of external immobilization. We investigate a two-step iterative motion compensation based on a multi-component metric of image sharpness. Methods: Motion is considered with respect to locally rigid motion within a particular region of interest, and the method supports application to multiple locally rigid regions. Motion is estimated by maximizing a cost function with three components: a gradient metric encouraging image sharpness, an entropy term that favors high contrast and penalizes streaks, and a penalty term encouraging smooth motion. Motion compensation involved initial coarse estimation of gross motion followed by estimation of fine-scale displacements using high resolution reconstructions. The method was evaluated in simulations with synthetic motion (1–4 mm) applied to a wrist volume obtained on a CMOS-based CBCT testbench. Structural similarity index (SSIM) quantified the agreement between motion-compensated and static data. The algorithm was also tested on a motion contaminated patient scan from dedicated extremities CBCT. Results: Excellent correction was achieved for the investigated range of displacements, indicated by good visual agreement with the static data. 10-15% improvement in SSIM was attained for 2-4 mm motions. The compensation was robust against increasing motion (4% decrease in SSIM across the investigated range, compared to 14% with no compensation). Consistent performance was achieved across a range of noise levels. Significant mitigation of artifacts was shown in patient data. Conclusion: The results indicate feasibility of image-based motion correction in extremities CBCT without the need for a priori motion models, external trackers, or fiducials.

[1]  Matthew W. Jacobson,et al.  Compensating for head motion in slowly-rotating cone beam CT systems with optimization transfer based motion estimation , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[2]  R Fahrig,et al.  Marker-free motion correction in weight-bearing cone-beam CT of the knee joint. , 2016, Medical physics.

[3]  Nikolaus Hansen,et al.  Evaluating the CMA Evolution Strategy on Multimodal Test Functions , 2004, PPSN.

[4]  Rebecca Fahrig,et al.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization. , 2013, Medical physics.

[5]  Mathias Unberath,et al.  Image-based compensation for involuntary motion in weight-bearing C-arm cone-beam CT scanning of knees , 2015, Medical Imaging.

[6]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[7]  Yiannis Kyriakou,et al.  Image features for misalignment correction in medical flat-detector CT. , 2012, Medical physics.

[8]  T Varslot,et al.  Reliable automatic alignment of tomographic projection data by passive auto-focus. , 2011, Medical physics.

[9]  Marcus Brehm,et al.  Artifact-resistant motion estimation with a patient-specific artifact model for motion-compensated cone-beam CT. , 2013, Medical physics.

[10]  Z Kuncic,et al.  A rigid motion correction method for helical computed tomography (CT) , 2015, Physics in medicine and biology.

[11]  Rebecca Fahrig,et al.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment. , 2014, Medical physics.

[12]  Jeffrey A. Fessler,et al.  3D Forward and Back-Projection for X-Ray CT Using Separable Footprints , 2010, IEEE Transactions on Medical Imaging.

[13]  D. Yang,et al.  A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization. , 2011, Medical physics.