Computer-controlled mechanical simulation of the artificially ventilated human respiratory system

A mechanical lung simulator can be used to simulate specific lung pathologies, to test lung-function equipment, and in instruction. A new approach to mechanical simulation of lung behavior is introduced that uses a computer-controlled active mechatronic system. The main advantage of this approach is that the static and dynamic properties of the simulator can easily be adjusted via the control software. A nonlinear single-compartment mathematical model of the artificially ventilated respiratory system has been derived and incorporated into the simulator control system. This model can capture both the static and dynamic compliance of the respiratory system as well as nonlinear flow-resistance properties. Parameters in this model can be estimated by using data from artificially ventilated patients. It is shown that the simulation model fits patient data well. This mathematical model of the respiratory system was then matched to a model of the available physical equipment (the simulator, actuators, and the interface electronics) in order to obtain the desired lung behavior. A significant time delay in the piston motion control loop has been identified, which can potentially cause oscillations or even instability for high compliance values. Therefore, a feedback controller based on the Smith-predictor scheme was developed to control the piston motion. The control system, implemented on a personal computer, also includes a user-friendly interface to allow easy parameter setting.

[1]  A Rossi,et al.  Analysis of the behavior of the respiratory system with constant inspiratory flow. , 1985, Journal of applied physiology.

[2]  E SALAZAR,et al.  AN ANALYSIS OF PRESSURE-VOLUME CHARACTERISTICS OF THE LUNGS. , 1964, Journal of applied physiology.

[3]  Kenneth Levenberg A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .

[4]  W. B. Saunders A Textbook of Physiology , 1932, Nature.

[5]  J. Sharp,et al.  Hysteresis and stress adaptation in the human respiratory system. , 1967, Journal of applied physiology.

[6]  M. Stenbeck,et al.  Respiratory system. , 1995, Acta oncologica.

[7]  P S Crooke,et al.  Comparison of mathematical and mechanical models of pressure-controlled ventilation. , 1993, Journal of applied physiology.

[8]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[9]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[10]  W. H. Howell,et al.  A TEXTBOOK OF PHYSIOLOGY , 1934 .

[11]  Astrom Computer Controlled Systems , 1990 .

[12]  J. Butler,et al.  Mechanical properties of the lung. , 1960, British Journal of Diseases of the Chest.

[13]  N. Dudney,et al.  Diffusion of hydrogen in Pb β‘ alumina , 1985 .

[14]  Gaston H. Gonnet,et al.  On the LambertW function , 1996, Adv. Comput. Math..

[15]  Anton F. M. Verbraak,et al.  Estimation of respiratory parameters via fuzzy clustering , 2001, Artif. Intell. Medicine.

[16]  F Chabot,et al.  Respiratory mechanics studied by multiple linear regression in unsedated ventilated patients. , 1992, The European respiratory journal.

[17]  Lennart Ljung,et al.  Modeling Of Dynamic Systems , 1994 .

[18]  J. Hildebrandt,et al.  Pressure-volume data of cat lung interpreted by a plastoelastic, linear viscoelastic model. , 1970, Journal of applied physiology.

[19]  J. Bates,et al.  Two-compartment modelling of respiratory system mechanics at low frequencies: gas redistribution or tissue rheology? , 1991, The European respiratory journal.

[20]  J. West Bioengineering aspects of the lung , 1977 .

[21]  B Suki Nonlinear phenomena in respiratory mechanical measurements. , 1993, Journal of applied physiology.

[22]  R. Mann,et al.  Human Physiology , 1839, Nature.