A Distributed Measurement System for Correlating Faults to Lightning in Distribution Networks
暂无分享,去创建一个
Mario Paolone | Lorenzo Peretto | Roberto Tinarelli | Alberto Borghetti | Carlo Alberto Nucci | Fabio Napolitano | Koichi Yamabuki | M. Bernardi | Roberto Vitale
[1] N. Balijepalli,et al. Distribution system reliability assessment due to lightning storms , 2005, IEEE Transactions on Power Delivery.
[2] Vladimir A. Rakov,et al. Testing of the LIOV-EMTP96 Code for Computing Lightning-Induced Currents on Real Distribution Lines: Triggered-Lightning Experiments , 2004 .
[3] Alessandro Ferrero,et al. A distributed system for electric power quality measurement , 2002, IEEE Trans. Instrum. Meas..
[4] Farhad Rachidi,et al. Lightning-induced voltages on complex distribution systems: models, advanced software tools and experimental validation , 2004 .
[5] Ashok K. Agrawal,et al. Transient Response of Multiconductor Transmission Lines Excited by a Nonuniform Electromagnetic Field , 1980 .
[6] R. B. Anderson. Lightning performance criteria for electric power systems , 1985 .
[7] M. Paolone,et al. A Statistical Approach for Estimating the Correlation between Lightning and Faults in Power Distribution Systems , 2006, 2006 International Conference on Probabilistic Methods Applied to Power Systems.
[8] Martin A. Uman,et al. Transient electric and magnetic fields associated with establishing a finite electrostatic dipole , 1983 .
[9] E. Gunther,et al. A survey of distribution system power quality-preliminary results , 1995 .
[10] V. Kinnares,et al. Analysis of harmonic for 12-pulse converter under unbalanced voltage operation due to lightning related voltage sags and short interruption , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).
[11] M. Ianoz,et al. On lightning return stroke models for LEMP calculations , 1988 .
[12] Vernon Cooray,et al. Underground electromagnetic fields generated by the return strokes of lightning flashes , 2001 .
[13] M. Ianoz,et al. Influence of a lossy ground on lightning-induced voltages on overhead lines , 1996 .
[14] Vernon Cooray,et al. Horizontal fields generated by return strokes , 1992 .
[15] Mario Paolone,et al. Lightning-Induced Voltages on Overhead Distribution Lines: Theoretical and Experimental Investigation of Related Problems and their Impact on Power Quality , 2004 .
[16] Giovanni Bucci,et al. Digital measurement station for power quality analysis in distributed environments , 2003, IEEE Trans. Instrum. Meas..
[17] Mario Paolone,et al. On the use of data from distributed measurement systems for correlating voltage transients to lightning , 2004, IEEE Transactions on Instrumentation and Measurement.
[18] Kenneth L. Cummins,et al. The U.S. National Lightning Detection NetworkTM and Applications of Cloud-to-Ground Lightning Data by Electric Power Utilities , 1998 .
[19] M. Rubinstein,et al. An approximate formula for the calculation of the horizontal electric field from lightning at close, intermediate, and long range , 1996 .
[20] A. Piantini,et al. A Scale Model for the Study of the LEMP Response of Complex Power Distribution Networks , 2007, IEEE Transactions on Power Delivery.
[21] R. Sasdelli,et al. A system for the measurement of the starting instant of impulsive transients [power systems] , 2004, Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510).
[22] Farhad Rachidi,et al. Interaction of electromagnetic fields with electrical networks generated by lightning , 2003 .
[23] J. G. Kappenman,et al. Location-centered mitigation of lightning-caused disturbances , 1996 .