Comparative analysis of intensity modulation inverse planning modules of three commercial treatment planning systems applied to head and neck tumour model.

BACKGROUND AND PURPOSE Three commercial treatment planning modules for intensity modulated radiation therapy (IMRT) Inverse Planning, MDS-Nordion Helax-TMS, Varian Cadplan-Helios, and CMS Focus, were compared in an attempt to determine potential application limits or dosimetric differences among various optimisation algorithms. MATERIALS AND METHODS A comparative analysis of intensity modulated dose distributions was conducted at planning level on a group of four patients presenting advanced head and neck cancers. In the study, we analysed primarily the static 'step and shoot' multileaf implementation of modulation realisation with some investigation, on the Cadplan-Helios implementation of the 'sliding window', the Varian dynamic approach to IMRT delivery. The whole study was carried out using the inverse planning tools implemented by vendors fully optimising each plan to obtain the best dosimetry given some general plan objectives. To achieve adequate target coverage, optimisation was carried out on Helax-TMS and CMS Focus adding extra margins of 5 or 6mm to the planning target volume (PTV). Beam arrangements were set with five and nine equally spaced fields. The study was conducted with two complexity levels. At the first level, dose-volume constraints were applied only to the target volume and to the spinal cord, while parotid glands were added at the second level. The relative values of dose distributions and dose-volume histograms were compared, together with an estimate of the biological implications in terms of Equivalent Uniform Dose to the target. In the Cadplan-Helios system also the dosimetric implications of the number of intensity levels selected for the discretisation of the fluence matrix were investigated. RESULTS With the application of common planning strategies and the proper consideration of treatment planning system (TPS) specific features (e.g. the PTV margin problem), no substantial differences among the three algorithms were demonstrated at the first level for PTV and spinal cord. At the second level of the study differences were outlined for Helax-TMS, where sub-optimal results were obtained with the 5-field geometry. Mainly due to the differences in optimisation volumes, Cadplan-Helios presented significant better sparing of healthy tissue around the PTV, in terms of mean dose to healthy tissue and Irradiated Volume at 50% dose level. Finally, to achieve dosimetrically acceptable and stable results on target, a minimum of eight intensity levels should be applied for the multileaf collimator (MLC) segmentation, giving an average of 1.5 segments per field and per intensity level. CONCLUSIONS Results obtained for the three IMRT TPS show in first instance that the optimisation algorithms analysed, as well as the conversion from computed fluences to multileaf sequences implemented in the planning systems can produce substantially equivalent dose plans (for target coverage and organs at risk sparing) if planning is performed with common strategies and once a strong understanding of each system feature is achieved. Secondly, a limited number of dose levels (about eight) is adequate at planning level.

[1]  P Xia,et al.  Comparison of treatment plans involving intensity-modulated radiotherapy for nasopharyngeal carcinoma. , 2000, International journal of radiation oncology, biology, physics.

[2]  W Schlegel,et al.  Intensity modulation with the "step and shoot" technique using a commercial MLC: a planning study. Multileaf collimator. , 1999, International journal of radiation oncology, biology, physics.

[3]  L J Verhey,et al.  Comparison of three-dimensional conformal radiation therapy and intensity-modulated radiation therapy systems. , 1999, Seminars in radiation oncology.

[4]  R Miralbell,et al.  Optimizing radiotherapy of orbital and paraorbital tumors: intensity-modulated X-ray beams vs. intensity-modulated proton beams. , 2000, International journal of radiation oncology, biology, physics.

[5]  R Svensson,et al.  Simultaneous optimization of dynamic multileaf collimation and scanning patterns or compensation filters using a generalized pencil beam algorithm. , 1995, Medical physics.

[6]  T. Bortfeld,et al.  X-ray field compensation with multileaf collimators. , 1994, International journal of radiation oncology, biology, physics.

[7]  A Fogliata,et al.  A treatment planning comparison of 3D conformal therapy, intensity modulated photon therapy and proton therapy for treatment of advanced head and neck tumours. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  A Lomax,et al.  The exchange of radiotherapy data as part of an electronic patient-referral system. , 2000, International journal of radiation oncology, biology, physics.

[9]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[10]  D. Convery,et al.  The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation , 1992 .

[11]  V. Marchesi,et al.  Étude comparative dosimétrique de deux méthodes de modulation d'intensité réalisées sur le même accélérateur , 2000 .

[12]  R. Siochi,et al.  Minimizing static intensity modulation delivery time using an intensity solid paradigm. , 1999, International journal of radiation oncology, biology, physics.

[13]  M. Goitein,et al.  Tolerance of normal tissue to therapeutic irradiation. , 1991, International journal of radiation oncology, biology, physics.

[14]  R Mohan,et al.  The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy. , 2000, Medical physics.

[15]  Jorge Nocedal,et al.  A Limited Memory Algorithm for Bound Constrained Optimization , 1995, SIAM J. Sci. Comput..

[16]  A J Lomax,et al.  A treatment planning inter-comparison of proton and intensity modulated photon radiotherapy. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  A. Fogliata,et al.  Critical appraisal of a conformal head and neck cancer irradiation avoiding electron beams and field matching. , 1999, International journal of radiation oncology, biology, physics.

[18]  S. Spirou,et al.  Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations. , 1994, Medical physics.

[19]  A Fogliata,et al.  Dosimetric features of linac head and phantom scattered radiation outside the clinical photon beam: experimental measurements and comparison with treatment planning system calculations. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  A. Brahme,et al.  A generalized pencil beam algorithm for optimization of radiation therapy. , 1994, Medical physics.

[21]  M Miften,et al.  Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system. , 2000, Physics in medicine and biology.

[22]  A. Niemierko Reporting and analyzing dose distributions: a concept of equivalent uniform dose. , 1997, Medical physics.

[23]  S. Spirou,et al.  Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators. , 1994, Medical physics.

[24]  G T Chen,et al.  Fast iterative algorithms for three-dimensional inverse treatment planning. , 1998, Medical physics.

[25]  T. Bortfeld,et al.  Characterization of dose distribution in radiation therapy plans. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[26]  G J Kutcher,et al.  The potential and limitations of the inverse radiotherapy technique. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.