Silicon microsystems for neuroscience and neural prostheses

Silicon-based microsystems are being developed to interface with the central nervous system (CNS) at the cellular level. Dense three-dimensional (3-D) microelectrode arrays with as many as several hundred sites permit acute and semichronic single-unit recording and stimulation, while on-chip circuitry for site selection, amplification, and multiplexing reduces noise and limits the number of output leads to manageable levels. Hybrid implant-mounted circuitry can be used to separate single units from baseline noise and provide simultaneous wireless access to more than a hundred information channels. This article focuses on the technology for electronically interfacing with the CNS at the cellular level. Devices based on silicon-on-insulator technology and silicon array structures not based as directly on the planar processes of ICs are given notice. Tissue interface and cabling problems still exist for long-term applications but the basic technology platform is robust and should allow engineering solutions to be developed over time. Present technology is consistent with real breakthroughs in our understanding of the brain at the circuit/system level during the coming decade though detailed mapping that has been impossible in the past. Such mapping could also serve as a basis for prosthetic devices for treating some of mankind's most debilitating disorders.

[1]  S. Shamma,et al.  A tantalum-on-sapphire microelectrode array , 1979, IEEE Transactions on Electron Devices.

[2]  K. Wise,et al.  A fully-integrated bandpass amplifier for extracellular neural recording , 2003, First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings..

[3]  Daryl R. Kipke,et al.  Wireless implantable microsystems: high-density electronic interfaces to the nervous system , 2004, Proceedings of the IEEE.

[4]  H. K. Charles,et al.  Multisite microprobes for neural recordings , 1991, IEEE Transactions on Biomedical Engineering.

[5]  Qing Bai,et al.  A high-yield microassembly structure for three-dimensional microelectrode arrays , 2000, IEEE Transactions on Biomedical Engineering.

[6]  P.T. Bhatti,et al.  A high-density electrode array for a cochlear prosthesis , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[7]  James D. Meindl,et al.  Integrated circuits for a bidirectional implantable pulsed Doppler ultrasonic blood flowmeter , 1978 .

[8]  J. Csicsvari,et al.  Mechanisms of Gamma Oscillations in the Hippocampus of the Behaving Rat , 2003, Neuron.

[9]  R A Normann,et al.  The Utah intracortical Electrode Array: a recording structure for potential brain-computer interfaces. , 1997, Electroencephalography and clinical neurophysiology.

[10]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[11]  U. Hofmann,et al.  Institute of Physics Publishing Journal of Micromechanics and Microengineering a 32-site Neural Recording Probe Fabricated by Drie of Soi Substrates , 2022 .

[12]  R. Olsson,et al.  A three-dimensional neural recording microsystem with implantable data compression circuitry , 2005, ISSCC. 2005 IEEE International Digest of Technical Papers. Solid-State Circuits Conference, 2005..

[13]  Luke P. Lee,et al.  Implantable multichannel electrode array based on SOI technology , 2003 .

[14]  K.D. Wise,et al.  A three-dimensional neural recording microsystem with implantable data compression circuitry , 2005, IEEE Journal of Solid-State Circuits.

[15]  J. Hetke,et al.  Surface modification of neural recording electrodes with conducting polymer/biomolecule blends. , 2001, Journal of biomedical materials research.

[16]  M. Kuperstein,et al.  A Practical 24 Channel Microelectrode for Neural Recording in Vivo , 1981, IEEE Transactions on Biomedical Engineering.

[17]  Khalil Najafi,et al.  An Ultra-Thin Hermetic Package Utilizing Electroplated Gold , 2001 .

[18]  O. Prohaska,et al.  Thin-Film Multiple Electrode Probes: Possibilities and Limitations , 1986, IEEE Transactions on Biomedical Engineering.

[19]  Sung June Kim,et al.  A micromachined silicon depth probe for multichannel neural recording , 2000, IEEE Transactions on Biomedical Engineering.

[20]  G. E. Loeb,et al.  Analysis and microelectronic design of tubular electrode arrays intended for chronic, multiple singleunit recording from captured nerve fibres , 1977, Medical and Biological Engineering and Computing.

[21]  G. Loeb,et al.  A miniature microelectrode array to monitor the bioelectric activity of cultured cells. , 1972, Experimental cell research.

[22]  K. Wise,et al.  An integrated-circuit approach to extracellular microelectrodes. , 1970, IEEE transactions on bio-medical engineering.

[23]  K. Wise,et al.  An IC piezoresistive pressure sensor for biomedical instrumentation. , 1973, IEEE transactions on bio-medical engineering.

[24]  Hao Yu A wireless microsystem for multichannel neural recording microprobes. , 2004 .

[25]  J. D. Meindl,et al.  Micropower integrated circuits for an implantable pulsed-doppler ultrasonic blood flowmeter , 1975 .

[26]  K. Wise,et al.  A shuttered probe with in-line flowmeters for chronic in-vivo drug delivery , 2001, Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090).

[27]  K. Wise,et al.  An implantable multielectrode array with on-chip signal processing , 1986 .

[28]  K. Najafi,et al.  Long-term testing of hermetic anodically bonded glass-silicon packages , 2002, Technical Digest. MEMS 2002 IEEE International Conference. Fifteenth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.02CH37266).

[29]  James D. Meindl,et al.  MOS electronics for a portable reading aid for the blind , 1972 .

[30]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[31]  Kensall D. Wise,et al.  A 256-Site 3D CMOS Microelectrode Array for Multipoint Stimulation and Recording in the Central Nervous System , 2001 .

[32]  James D. Plummer,et al.  Integrated Electronics for a Reading Aid for the Blind , 1969 .

[33]  G. E. Perlin,et al.  The effect of the substrate on the extracellular neural activity recorded micromachined silicon microprobes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[34]  J. Borky,et al.  Integrated signal conditioning for diaphragm pressure sensors , 1979, 1979 IEEE International Solid-State Circuits Conference. Digest of Technical Papers.

[35]  James M. Bower,et al.  Plasma-etched neural probes , 1996 .

[36]  R. J. Vetter,et al.  Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[37]  K.D. Wise,et al.  A fully integrated multisite pressure sensor for wireless arterial flow characterization , 2006, Journal of Microelectromechanical Systems.

[38]  J. Hetke,et al.  Strength characterization of silicon microprobes in neurophysiological tissues , 1990, IEEE Transactions on Biomedical Engineering.

[39]  Eduardo Fernandez,et al.  High-resolution spatio-temporal mapping of visual pathways using multi-electrode arrays , 2001, Vision Research.

[40]  Kensall D. Wise,et al.  A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology , 1975, IEEE Transactions on Biomedical Engineering.

[41]  J. Csicsvari,et al.  Massively parallel recording of unit and local field potentials with silicon-based electrodes. , 2003, Journal of neurophysiology.