An introduction to fluorescence imaging techniques geared towards biosensor applications.

After providing a brief overview of the basics of fluorescence and FRET, this chapter discusses the most commonly used methods to record FRET. Emphasis is on microscopy methods that are widely used for biosensor imaging. We cover choice of instruments, describe various ways to detect FRET based on intensity as well as on donor lifetime, and provide some guidelines to match particular recording methods with specific scientific experiments. We end with an extensive discussion on further practical considerations that may greatly affect the success of the experiments.

[1]  Jennifer C. Waters,et al.  Accuracy and precision in quantitative fluorescence microscopy , 2009, The Journal of cell biology.

[2]  Erez Raz,et al.  Imaging protein activity in live embryos using fluorescence resonance energy transfer biosensors , 2011, Nature Protocols.

[3]  W. Almers,et al.  A real-time view of life within 100 nm of the plasma membrane , 2001, Nature Reviews Molecular Cell Biology.

[4]  Joachim Goedhart,et al.  Sensitive Detection of p65 Homodimers Using Red-Shifted and Fluorescent Protein-Based FRET Couples , 2007, PloS one.

[5]  P J Verveer,et al.  Quantitative imaging of lateral ErbB1 receptor signal propagation in the plasma membrane. , 2000, Science.

[6]  Kees Jalink,et al.  Detecting cAMP‐induced Epac activation by fluorescence resonance energy transfer: Epac as a novel cAMP indicator , 2004, EMBO reports.

[7]  David Baker,et al.  Ca2+ indicators based on computationally redesigned calmodulin-peptide pairs. , 2006, Chemistry & biology.

[8]  A. Pietraszewska-Bogiel,et al.  FRET microscopy: from principle to routine technology in cell biology , 2011, Journal of microscopy.

[9]  A. Nakano Spinning-disk confocal microscopy -- a cutting-edge tool for imaging of membrane traffic. , 2002, Cell structure and function.

[10]  Joachim Goedhart,et al.  Structure-guided evolution of cyan fluorescent proteins towards a quantum yield of 93% , 2012, Nature Communications.

[11]  Kees Jalink,et al.  Correcting confocal acquisition to optimize imaging of fluorescence resonance energy transfer by sensitized emission. , 2004, Biophysical journal.

[12]  T. Gadella,et al.  FRET and FLIM techniques , 2009 .

[13]  J. Ogink,et al.  A Comparison of Donor-Acceptor Pairs for Genetically Encoded FRET Sensors: Application to the Epac cAMP Sensor as an Example , 2008, PloS one.

[14]  Seok-Jin R. Lee,et al.  Activation of CaMKII in single dendritic spines during long-term potentiation , 2009, Nature.