Accuracy and precision of test weighing to assess milk intake in newborn infants

Background: Test weighing is commonly used to estimate milk intake in newborn infants. Objective: To assess the accuracy and precision of test weighing in clinical practice. Methods: Infants fed by bottle, cup, or nasogastric tube were weighed before and immediately after feeding by a blinded investigator. Actual milk intake was determined by reading the millilitre scale of the milk container before and after feeding. The accuracy and precision of test weighing was assessed by examining the frequency distribution of the difference between weight change and actual milk intake. Results: Ninety four infants completed the study. The mean difference between weight change and actual milk intake was 1.3 ml, indicating good accuracy. The precision of test weighing, however, was poor: 95% of differences between weight change and actual milk intake ranged from −12.4 to 15 ml. The maximum difference was 30 ml. Imprecision was not influenced by the presence of monitor or oxygen saturation wires, intravenous lines, or vomiting of the infant. Conclusions: Test weighing is an imprecise method for assessing milk intake in young infants. This is probably because infant weighing scales are not sensitive enough to pick up small changes in an infant’s weight after feeding. Because of its unreliability, test weighing should not be used in clinical practice.

[1]  M. P. Alexander,et al.  Assessment of infant feeding: the validity of measuring milk intake. , 2002, Nutrition reviews.

[2]  P. Meier,et al.  Estimating Milk Intake of Hospitalized Preterm Infants Who Breastfeed , 1996, Journal of human lactation : official journal of International Lactation Consultant Association.

[3]  P. Meier,et al.  A New Scale for In-Home Test-Weighing for Mothers of Preterm and High Risk Infants , 1994, Journal of human lactation : official journal of International Lactation Consultant Association.

[4]  B. Thomsen,et al.  The Copenhagen Cohort Study on Infant Nutrition and Growth: breast-milk intake, human milk macronutrient content, and influencing factors. , 1994, The American journal of clinical nutrition.

[5]  J. Kent,et al.  The determination of short‐term breast volume changes and the rate of synthesis of human milk using computerized breast measurement , 1992, Experimental physiology.

[6]  P. Meier,et al.  The Accuracy of Test Weighing for Preterm Infants , 1990, Journal of pediatric gastroenterology and nutrition.

[7]  K. Amatayakul,et al.  Indirect test weighing: a non-intrusive technique for estimating night-time breast milk intake. , 1987, Human nutrition. Clinical nutrition.

[8]  P. Arthur,et al.  Measurement of the milk intake of breast-fed infants. , 1987, Journal of pediatric gastroenterology and nutrition.

[9]  R. Hannemann,et al.  Evaluation of test-weighing for the assessment of milk volume intake of formula-fed infants and its application to breast-fed infants. , 1986, The American journal of clinical nutrition.

[10]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[11]  M. Neville,et al.  Accuracy of single- and two-feed test weighing in assessing 24 h breast milk production. , 1984, Early human development.

[12]  M. Whitfield,et al.  Validity of routine clinical test weighing as a measure of the intake of breast-fed infants. , 1981, Archives of disease in childhood.

[13]  M. Whitfield,et al.  How accurate is clinical test weighing of the newborn? , 1980, Midwives chronicle.