Hyperpolarized 3He magnetic resonance functional imaging semiautomated segmentation.

RATIONALE AND OBJECTIVES To improve intra- and interobserver variability and enable the use of functional magnetic resonance imaging (MRI) for multicenter, multiobserver studies, we generated a semiautomated segmentation method for hyperpolarized helium-3 ((3)He) MRI. Therefore the objective of this study was to compare the reproducibility and spatial agreement of manual and semiautomated segmentation of (3)He MRI ventilation defect volume (VDV) and ventilation volume (VV) in subjects with asthma, chronic obstructive pulmonary disease (COPD), and cystic fibrosis (CF). MATERIALS AND METHODS The multistep semiautomated segmentation method we developed employed hierarchical K-means clustering to classify (3)He MRI pixel intensity values into five user-determined clusters ranging from signal void to hyperintense. A seeded region-growing algorithm was also used to segment the (1)H MRI thoracic cavity for coregistration to the (3)He cluster-map, generating VDV and VV. RESULTS We compared manual segmentation performed by an expert observer and semiautomated measurements of (3)He MRI VDV and observed strong significant correlations between the volumes generated using each method (asthma, n = 5, r = 0.89, P < .0001; COPD, n = 5, r = 0.84, P < .0001; CF, n = 5, r = 0.89, P < .0001). Semiautomated VDV had high interobserver reproducibility (coefficient of variation [CV] = 7%, intraclass correlation coefficient [ICC] = 0.96); intraobserver reproducibility was significantly higher for semiautomated (CV = 5%, ICC = 1.00) compared to manual VDV (CV = 12%, ICC = 0.98). Spatial agreement for VV determined using the Dice coefficient (D) was also high for all disease states (asthma, D = 0.95; COPD, D = 0.88; CF, D = 0.90). CONCLUSIONS Semiautomated segmentation (3)He MRI provides excellent inter- and intraobserver precision with high spatial and quantitative agreement with manual measurements enabling its use in longitudinal studies.

[1]  S. Walter,et al.  Sample size and optimal designs for reliability studies. , 1998, Statistics in medicine.

[2]  John P Mugler,et al.  Evaluation of asthma with hyperpolarized helium-3 MRI: correlation with clinical severity and spirometry. , 2006, Chest.

[3]  Edwin J R van Beek,et al.  Quantitative analysis of regional airways obstruction using dynamic hyperpolarized 3He MRI—Preliminary results in children with cystic fibrosis , 2005, Journal of magnetic resonance imaging : JMRI.

[4]  Miranda Kirby,et al.  Development and application of methods to quantify spatial and temporal hyperpolarized 3He MRI ventilation dynamics: preliminary results in chronic obstructive pulmonary disease , 2010, Medical Imaging.

[5]  M Thelen,et al.  Imaging of the lungs using 3he MRI: Preliminary clinical experience in 18 patients with and without lung disease , 1997, Journal of magnetic resonance imaging : JMRI.

[6]  J R Brookeman,et al.  Lung air spaces: MR imaging evaluation with hyperpolarized 3He gas. , 1999, Radiology.

[7]  Jim M. Wild,et al.  Feasibility of Image Registration and Intensity-Modulated Radiotherapy Planning With Hyperpolarized Helium-3 Magnetic Resonance Imaging for Non–Small-Cell Lung Cancer , 2007, International journal of radiation oncology, biology, physics.

[8]  Masaru Ishii,et al.  A robust method for estimating regional pulmonary parameters in presence of noise. , 2008, Academic radiology.

[9]  Grace Parraga,et al.  Hyperpolarized 3He magnetic resonance imaging of chronic obstructive pulmonary disease: reproducibility at 3.0 tesla. , 2008, Academic radiology.

[10]  Aaron Fenster,et al.  Hyperpolarized 3He Ventilation Defects and Apparent Diffusion Coefficients in Chronic Obstructive Pulmonary Disease: Preliminary Results at 3.0 Tesla , 2007, Investigative radiology.

[11]  G. Parraga,et al.  Detection of longitudinal lung structural and functional changes after diagnosis of radiation-induced lung injury using hyperpolarized 3He magnetic resonance imaging. , 2009, Medical physics.

[12]  G. Parraga,et al.  Mapping and quantifying hyperpolarized 3He magnetic resonance imaging apparent diffusion coefficient gradients. , 2008, Journal of applied physiology.

[13]  H C Charles,et al.  Cystic fibrosis: combined hyperpolarized 3He-enhanced and conventional proton MR imaging in the lung--preliminary observations. , 1999, Radiology.

[14]  Grace Parraga,et al.  Hyperpolarized 3He magnetic resonance imaging of ventilation defects in healthy elderly volunteers: initial findings at 3.0 Tesla. , 2008, Academic radiology.

[15]  Aaron Fenster,et al.  Quantification of carotid plaque volume measurements using 3D ultrasound imaging. , 2005, Ultrasound in medicine & biology.

[16]  Scott T. Acton,et al.  Merging parametric active contours within homogeneous image regions for MRI-based lung segmentation , 2003, IEEE Transactions on Medical Imaging.

[17]  Rolf Adams,et al.  Seeded Region Growing , 1994, IEEE Trans. Pattern Anal. Mach. Intell..

[18]  Mark G. Vangel,et al.  Confidence Intervals for a Normal Coefficient of Variation , 1996 .

[19]  J. MacQueen Some methods for classification and analysis of multivariate observations , 1967 .

[20]  Eduard E de Lange,et al.  MRI of the lungs using hyperpolarized noble gases , 2002, Magnetic resonance in medicine.

[21]  John P Mugler,et al.  Feature analysis of hyperpolarized helium‐3 pulmonary MRI: A study of asthmatics versus nonasthmatics , 2010, Magnetic resonance in medicine.

[22]  J. Wild,et al.  Single‐scan acquisition of registered hyperpolarized 3He ventilation and ADC images using a hybrid 2D gradient‐echo sequence , 2007, Magnetic resonance in medicine.

[23]  Miranda Kirby,et al.  Chronic obstructive pulmonary disease: longitudinal hyperpolarized (3)He MR imaging. , 2010, Radiology.

[24]  M. Eliasziw,et al.  Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. , 1994, Physical therapy.

[25]  Eduard E de Lange,et al.  Hyperpolarized HHe 3 MRI of the lung in cystic fibrosis: assessment at baseline and after bronchodilator and airway clearance treatment. , 2005, Academic radiology.

[26]  D. Yablonskiy,et al.  Rapid imaging of hyperpolarized gas using EPI , 1999, Magnetic resonance in medicine.

[27]  L. R. Dice Measures of the Amount of Ecologic Association Between Species , 1945 .

[28]  T A Altes,et al.  Hyperpolarized 3He MR lung ventilation imaging in asthmatics: Preliminary findings , 2001, Journal of magnetic resonance imaging : JMRI.

[29]  G. Parraga,et al.  Hyperpolarized ³He magnetic resonance imaging: preliminary evaluation of phenotyping potential in chronic obstructive pulmonary disease. , 2011, European journal of radiology.

[30]  Helen Marshall,et al.  Synchronous acquisition of hyperpolarised 3He and 1H MR images of the lungs – maximising mutual anatomical and functional information , 2011, NMR in biomedicine.

[31]  S. Choy,et al.  Hyperpolarized (3)He magnetic resonance imaging-derived pulmonary pressure-volume curves. , 2010, Journal of applied physiology.

[32]  Kenneth Lutchen,et al.  The difference in ventilation heterogeneity between asthmatic and healthy subjects quantified using hyperpolarized 3He MRI. , 2009, Journal of applied physiology.

[33]  F. Martinez,et al.  Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: GOLD executive summary. , 2007, American journal of respiratory and critical care medicine.

[34]  Edwin J R van Beek,et al.  Combined helium‐3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never‐smokers , 2005, Journal of magnetic resonance imaging : JMRI.

[35]  M Salerno,et al.  Dynamic spiral MRI of pulmonary gas flow using hyperpolarized 3He: Preliminary studies in healthy and diseased lungs , 2001, Magnetic resonance in medicine.

[36]  John P Mugler,et al.  The variability of regional airflow obstruction within the lungs of patients with asthma: assessment with hyperpolarized helium-3 magnetic resonance imaging. , 2007, The Journal of allergy and clinical immunology.

[37]  J. MacFall,et al.  Hyperpolarized 3He-enhanced MR imaging of lung transplant recipients: preliminary results. , 1999, AJR. American journal of roentgenology.

[38]  H. Kauczor,et al.  Volumetry of Ventilated Airspaces by 3He MRI: Preliminary Results , 2001, Investigative radiology.

[39]  W. Busse,et al.  Evaluation of structure-function relationships in asthma using multidetector CT and hyperpolarized He-3 MRI. , 2008, Academic radiology.

[40]  E. V. van Beek,et al.  MR imaging of the lungs with hyperpolarized helium-3 gas transported by air. , 2002, Physics in medicine and biology.

[41]  Balthasar Eberle,et al.  Functional analysis in single-lung transplant recipients: a comparative study of high-resolution CT, 3He-MRI, and pulmonary function tests. , 2004, Chest.

[42]  M. Paley,et al.  Parallel imaging of hyperpolarized helium‐3 with simultaneous slice excitation , 2006, Magnetic resonance in medicine.