CdTe/CZT under high flux irradiation

Direct converting quantum counting detectors based on cadmium telluride and cadmium zinc telluride have been investigated with respect to their properties under intense X-ray irradiation. To derive a detailed picture of the performance of such detectors, the influence of the electric field, the detector thickness, the temperature and the intensity of the X-ray irradiation was studied. The results are discussed in terms of the ``polarization'' phenomenon, a reduction of the electric field strength inside the detector due to immobile charge carriers accumulating during irradiation. Furthermore, the impact of Te-inclusions and –precipitates is presented.

[1]  Y. Nemirovsky,et al.  Effect of the geometrical parameters on the electric field of pixelated two-dimensional arrays of γ-ray spectrometers , 2000 .

[2]  I. Turkevych,et al.  High-temperature electron and hole mobility in CdTe , 2002 .

[3]  P. Luke,et al.  Factors affecting energy resolution of coplanar-grid CdZnTe detectors , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[4]  M. Martini Semiconductor Radiation Probes for Nuclear Medicine and Radiobiology the State of the Art , 1973 .

[5]  F. Smith Electrically active point defects in cadmium telluride , 1970 .

[6]  Carrier transport properties of HPB CdZnTe and THM CdTe:Cl , 2001 .

[7]  K. Zanio Purification of CdTe from, tellurium-rich solutions , 1974 .

[8]  Matthias Simon,et al.  Towards direct conversion detectors for medical imaging with X-rays , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[9]  C. Jacoboni,et al.  A review of some charge transport properties of silicon , 1977 .

[10]  M. Funaki,et al.  THM Growth and Characterization of 100 mm Diameter CdTe Single Crystals , 2008, IEEE Transactions on Nuclear Science.

[11]  M. A. Wolf,et al.  Use of a Cadmium Telluride Detector in a New Tiny Personal Radiation Chirper , 1979, IEEE Transactions on Nuclear Science.

[12]  Jeffrey Frey,et al.  Electron velocity in Si and GaAs at very high electric fields , 1980 .

[13]  A. Loutchanski,et al.  Correlation between quality of CZT crystals and spectrometric performance of hemispherical radiation detectors , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[14]  M. Lorenz,et al.  Electrical Properties ofn-Type CdTe , 1963 .

[15]  H. B. Barber,et al.  Signals induced in semiconductor gamma-ray imaging detectors , 1999 .

[16]  P. Sellin,et al.  Drift mobility and mobility-lifetime products in CdTe:Cl grown by the travelling heater method , 2005, IEEE Transactions on Nuclear Science.

[17]  P. Luke,et al.  Electron trapping nonuniformity in high-pressure-Bridgman-grown CdZnTe , 2002 .

[18]  Csaba Szeles,et al.  Nature of polarization in wide-bandgap semiconductor detectors under high-flux irradiation: Application to semi-insulating Cd 1 − x Zn x Te , 2008 .

[19]  Adriano Cola,et al.  The polarization mechanism in CdTe Schottky detectors , 2009 .

[20]  William C. Barber,et al.  Large area photon counting X-ray imaging arrays for clinical dual-energy applications , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[21]  C. Canali,et al.  Transport Properties of CdTe , 1971 .

[22]  M. Martini,et al.  Measurement of the Disappearance Rate of 75-Se Sodium Selenite in the Eye of the Rat by a CdTe Medical Probe , 1972 .

[23]  R. James,et al.  Modelling the effects of Te precipitates on the electron transport in CdZnTe radiation detectors , 2007 .

[24]  R. Triboulet,et al.  Growth of High Purity CdTe Single Crystals by Vertical Zone Melting , 1973 .

[25]  A Jahnke,et al.  Signal formation and decay in CdTe x-ray detectors under intense irradiation. , 1999, Medical physics.

[26]  Goro Sato,et al.  CdTe and CdZnTe detectors for timing measurements , 2001 .

[27]  John H. Reed,et al.  High-dynamic-range x-ray imager employing CdZnTe detector arrays , 1993, Optics & Photonics.

[28]  P. Siffert,et al.  Polarization in Cadmium Telluride Nuclear Radiation Detectors , 1976, IEEE Transactions on Nuclear Science.

[29]  F. P. Doty,et al.  Cd 1-x Zn x Te gamma ray detectors , 1991 .

[30]  B. Heismann,et al.  Spectral and spatial resolution of semiconductor detectors in medical X- and gamma ray imaging , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[31]  A. Cola,et al.  Study on instability phenomena in CdTe diode-like detectors , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[32]  F. P. Doty,et al.  Cd/sub 1-x/Zn/sub x/Te gamma ray detectors , 1992 .

[33]  M. Schieber,et al.  Reduction of Polarization in Mercuric Iodide Nuclear Radiation Detectors , 1980, IEEE Transactions on Nuclear Science.

[34]  D. Bale,et al.  Multiple-Scale Analysis of Charge Transport in Semiconductor Radiation Detectors: Application to Semi-Insulating CdZnTe , 2009 .

[35]  S. Kappler,et al.  Dual-energy performance of dual kVp in comparison to dual-layer and quantum-counting CT system concepts , 2009, Medical Imaging.

[36]  J. A. Jenkins,et al.  Development of IMARAD CZT detectors with PIN contacts , 1999, Optics & Photonics.

[37]  Aleksey E. Bolotnikov,et al.  Effect of Te precipitates on the performance of CdZnTe detectors , 2005 .

[38]  T. D. Reilly,et al.  Fundamentals of passive nondestructive assay of fissionable material , 1974 .

[39]  Edgar Kraft,et al.  A research prototype system for quantum-counting clinical CT , 2010, Medical Imaging.