Is It Safe to Back Out Pedicle Screws After Augmentation With Polymethyl Methacrylate or Calcium Phosphate Cement?: A Biomechanical Study

Study Design Biomechanical cadaveric study. Objective To determine the torque required to remove pedicle screws augmented with polymethyl methacrylate (PMMA) or calcium phosphate cement (CPC); thus, proving the safety of back out of augmented screws in the osteopotoric model, which would be a more dangerous setting than the nonosteoporotic model. Summary of Background Data To our knowledge, no earlier study has characterized the safety of backing out pedicle screw augmented with PMMA or CPC. Methods Pedicle screws were inserted in 24 osteoporotic vertebrae (48 pedicles). The maximal insertion torque and pullout strength of each screw were recorded. After pullout of the pedicle screws, the vertebrae were then randomized into 2 groups of 12 (24 pedicles) each. PMMA was injected into the pedicles in the first group and CPC was injected into the second group after which the pedicle screws were inserted. The pedicle screws were inserted into the pedicle holes augmented with PMMA or CPC, respectively. Finally, all augmented screws were backed out and the maximal removal torque was recorded using a digital torque wrench. Results Throughout the study, no incidence of pedicle or lamina fractures was observed. The average insertion torque was 0.5±0.27 and 0.45±0.29 N·m for groups 1 and 2, respectively (P=0.724). The average pullout strength was 723.1±391.7 and 671.2±383.0 N (P=0.950). After cement augmentation, the average removal torque was 0.77±0.31 and 0.81±0.26 N·m for PMMA and CPC, respectively (P=0.494). Conclusions The results of this study showed that pedicle screws can be easily and safely backed out after augmentation with PMMA or CPC. The result of CPC, however, may only be valid before any bony ingrowth.

[1]  Serkan Erkan,et al.  The Effect on the Pullout Strength by the Timing of Pedicle Screw Insertion After Calcium Phosphate Cement Injection , 2011, Journal of Spinal Disorders & Techniques.

[2]  R. McLain,et al.  Primary Pedicle Screw Augmentation in Osteoporotic Lumbar Vertebrae: Biomechanical Analysis of Pedicle Fixation Strength , 2007, Spine.

[3]  Chunhui Wu,et al.  Biomechanical Comparison of Anatomic Trajectory Pedicle Screw versus Injectable Calcium Sulfate Graft-Augmented Pedicle Screw for Salvage in Cadaveric Thoracic Bone , 2006, Journal of spinal disorders & techniques.

[4]  M. Kinoshita,et al.  Efficacy of novel-concept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine , 2005, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[5]  G. Andersson,et al.  Augmentation of Pedicle Screw Fixation Strength Using an Injectable Calcium Phosphate Cement as a Function of Injection Timing and Method , 2004, Spine.

[6]  Hiroshi Yamamoto,et al.  Enhancement of pedicle screw stability using calcium phosphate cement in osteoporotic vertebrae: in vivo biomechanical study , 2003, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[7]  W. Walsh,et al.  Hydroxyapatite Composite Resin Cement Augmentation of Pedicle Screw Fixation , 2003, Clinical orthopaedics and related research.

[8]  D. Spengler,et al.  Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength. , 2002, The spine journal : official journal of the North American Spine Society.

[9]  P Augat,et al.  A new bioresorbable polymer for screw augmentation in the osteosynthesis of osteoporotic cancellous bone: a biomechanical evaluation. , 2001, Journal of biomedical materials research.

[10]  B. V. van Royen,et al.  Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: an innovative technique , 2000, European Spine Journal.

[11]  S. Yerby,et al.  Revision of Failed Pedicle Screws Using Hydroxyapatite Cement: A Biomechanical Analysis , 1998, Spine.

[12]  J. Lotz,et al.  Carbonated Apatite Cement Augmentation of Pedicle Screw Fixation in the Lumbar Spine , 1997, Spine.

[13]  D. Moore,et al.  Restoration of Pedicle Screw Fixation With an in Situ Setting Calcium Phosphate Cement , 1997, Spine.

[14]  M. Krag,et al.  Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. , 1994, Spine.

[15]  K. Murota,et al.  An Experimental Study on Transpedicular Screw Fixation in Relation to Osteoporosis of the Lumbar Spine , 1991, Spine.