In-patient comparison of immediately loaded and non-loaded implants within 6 months.

According to the Brånemark protocol, a stress-free healing period is one of the most emphasised requirements for implant integration. Recent studies have encouraged a progressive shortening of the healing period and immediate loading has been proposed for the edentulous mandible. This prospective study evaluated the clinical outcomes of 14 immediately loaded FRIALIT-2(R) implants compared with 28 non-loaded controls in an in-patient study. The results were based on clinical stability and on changes of bone level from implant placement to abutment connection 6 months after insertion. In the course of our investigation, seven patients with edentulous mandibles have been treated with 43 implants following an immediate-loading protocol. Six FRIALIT-2(R) implants were placed in the interforaminal region located at positions 34, 33, 32, 42, 43, 44. Bone level in relation to implant margin was measured and recorded. In order to obtain an in-patient comparison of immediately loaded and non-loaded implants, the ones at 33 and 43 were chosen to be immediately loaded by a Dolder-bar retained overdenture. The implants in position 32, 34, 42 and 44 were covered and left to heal. After a healing period of 6 months, second stage surgery was carried out. The clinical criteria to be checked at this point were survival, Periotest values and marginal bone level at the loaded and non-loaded implants. The mean Periotest value was -2.7 for the loaded and -5.6 for the non-loaded implants. The Mann-Whitney U-test showed that the difference was highly significant (P < 0.001). The mean bone level changes at prosthetic delivery were 0.9 mm resorption for the loaded implants and 0.33 mm for non-loaded implants. The difference was highly significant (P < 0.001). No implant failures were observed up to the prosthetic restoration 6 months post insertion. The results of this investigation allowed for direct comparison of implant survival and clinical results between immediately loaded implants and standard implants. Clinical bone changes at the 6-month evaluation demonstrated significantly higher crestal resorption around loaded implants. This fact was confirmed by higher median Periotest values (-3 vs. -6) of immediately loaded implants. According to the outcome of this study, immediate loading of two interforaminal implants with a Dolder-bar resulted in an intimate bone apposition comparable with implants with submerged healing. Nevertheless, the coronal bone level as well as clinical stability (PTV) were significantly lower in the case of the immediately loaded implants. Future studies will be necessary to evaluate marginal bone resorption, Periotest values and clinical success rates of mandibular immediately loaded implants in the long-term.

[1]  U. Lekholm,et al.  One-step surgical placement of Brånemark implants: a prospective multicenter clinical study. , 1997, The International journal of oral & maxillofacial implants.

[2]  D van Steenberghe,et al.  Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report. , 1991, The Journal of prosthetic dentistry.

[3]  D. Misiek,et al.  Titanium plasma-sprayed (TPS) screw implants for the reconstruction of the edentulous mandible. , 1986, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[4]  K. Nilner,et al.  Early functional loading of Brånemark dental implants: 5-year clinical follow-up study. , 2000, Clinical implant dentistry and related research.

[5]  J. Rubenstein,et al.  Ten-year results for Brånemark implants immediately loaded with fixed prostheses at implant placement. , 1997, The International journal of oral & maxillofacial implants.

[6]  P. Branemark Osseointegration and its experimental background. , 1983, The Journal of prosthetic dentistry.

[7]  M. Chiapasco,et al.  Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. , 1997, Clinical oral implants research.

[8]  M. Chiapasco,et al.  Implant-retained mandibular overdentures with immediate loading: a prospective study of ITI implants. , 2000, The International journal of oral & maxillofacial implants.

[9]  P. Glantz,et al.  Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study. , 1999, Clinical oral implants research.

[10]  P. Glantz,et al.  Clinical and radiographical features of submerged and nonsubmerged titanium implants. , 1994, Clinical oral implants research.

[11]  G A Favero,et al.  Considerations preliminary to the application of early and immediate loading protocols in dental implantology. , 2000, Clinical oral implants research.

[12]  D Buser,et al.  Biologic width around titanium implants. A physiologically formed and stable dimension over time. , 2000, Clinical oral implants research.

[13]  J. Fiorellini,et al.  Comparison of healed tissues adjacent to submerged and non-submerged unloaded titanium dental implants. A histometric study in beagle dogs. , 1996, Clinical oral implants research.

[14]  A. Piattelli,et al.  Immediate loading of titanium plasma-sprayed implants: an histologic analysis in monkeys. , 1998, Journal of periodontology.

[15]  G. Wolfinger,et al.  IMMEDIATE LOADING OF BRÅNEMARK IMPLANTS IN EDENTULOUS MANDIBLES: A PRELIMINARY REPORT , 1997, Implant dentistry.

[16]  D Buser,et al.  Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants. , 1990, Clinical oral implants research.

[17]  F Sutter,et al.  The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces. , 1981, Journal of maxillofacial surgery.

[18]  L. Rose,et al.  Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics--a technique reexamined: two case reports. , 1995, The International journal of periodontics & restorative dentistry.

[19]  I Naert,et al.  Overdentures supported by osseointegrated fixtures for the edentulous mandible: a 2.5-year report. , 1988, The International journal of oral & maxillofacial implants.

[20]  H. Hansson,et al.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. , 1981, Acta orthopaedica Scandinavica.

[21]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[22]  D P Tarnow,et al.  Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. , 1997, The International journal of oral & maxillofacial implants.

[23]  P. Branemark,et al.  Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. , 1990, The International journal of oral & maxillofacial implants.

[24]  H Spiekermann,et al.  A 10-year follow-up study of IMZ and TPS implants in the edentulous mandible using bar-retained overdentures. , 1995, The International journal of oral & maxillofacial implants.

[25]  T Jemt,et al.  A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss. , 1996, Clinical oral implants research.