Ionic liquids as mobile phase additives in high-performance liquid chromatography with electrochemical detection: application to the determination of heterocyclic aromatic amines in meat-based infant foods.

The beneficial effects of several ionic liquids (ILs) as mobile phase additives in high-performance liquid chromatography with electrochemical detection for the determination of six heterocyclic aromatic amines (HAs) have been evaluated for first-time. The studied ionic liquids were 1-butyl-3-methylimidazolium tetrafluoroborate (BMIm-BF(4)), 1-hexyl-3-methylimidazolium tetrafluoroborate (HMIm-BF(4)) and 1-methyl-3-octylimidazolium tetrafluoroborate (MOIm-BF(4)). Several chromatographic parameters have been evaluated in the presence or absence of ILs, or using ammonium acetate as the most common mobile phase additive, with three different C18 stationary phases. The effect of the acetonitrile content was also addressed. In general, best resolution, lower peak-widths (up to 72.1% lower) and lower retention factors are obtained when using ILs rather than ammonium acetate as mobile phase additives. The main improvement was obtained in the baseline noise, being 360% less noisy for BMIm-BF(4), 310% for HMIm-BF(4), and 227% for MOIm-BF(4), when compared to ammonium acetate at +1000 mV. Different chromatographic methods using the best conditions for each IL were also evaluated and compared. Finally, the best chromatographic conditions using 1mM of BMIm-BF(4) as mobile phase additive, the Nova-Pak C18 column, 19% (v/v) of acetonitrile content in the mobile phase, and +1000 mV in the ECD, have been applied for the chromatographic analysis of six HAs contained in meat-based infant foods. The whole extraction method of meat-based infant foods using focused microwave-assisted extraction and solid-phase extraction has also been optimized. Extraction efficiencies up to 89% and detection limits ranged between 9.30 and 0.165 ng g(-1) have been obtained under optimized conditions.

[1]  Jingtian Hu,et al.  Use of ionic liquids for liquid-phase microextraction of polycyclic aromatic hydrocarbons. , 2003, Analytical chemistry.

[2]  Luis Cuadros Rodríguez,et al.  Estimation of Performance Characteristics of an Analytical Method Using the Data Set Of The Calibration Experiment , 1993 .

[3]  J. H. Ayala,et al.  Analytical methods applied to the determination of heterocyclic aromatic amines in foods. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[4]  Serge Rudaz,et al.  Characterization and comparison of the chromatographic performance of different types of reversed-phase stationary phases. , 2007, Journal of pharmaceutical and biomedical analysis.

[5]  M. Galceran,et al.  High-performance liquid chromatographic determination of ten heterocyclic aromatic amines with electrochemical detection , 1993 .

[6]  M. Galceran,et al.  Analysis of heterocyclic amines in chicken by liquid chromatography with electrochemical detection , 2005 .

[7]  R. Kaliszan,et al.  Reduction of silanophilic interactions in liquid chromatography with the use of ionic liquids , 2005 .

[8]  J. Flieger Effect of mobile phase composition on the retention of selected alkaloids in reversed-phase liquid chromatography with chaotropic salts. , 2007, Journal of chromatography. A.

[9]  M. Galceran,et al.  Ion-trap tandem mass spectrometry for the determination of heterocyclic amines in food. , 2002, Journal of chromatography. A.

[10]  M. Galceran,et al.  Evaluation of different clean-up procedures for the analysis of heterocyclic aromatic amines in a lyophilized meat extract. , 1999, Journal of chromatography. A.

[11]  J. Dorsey,et al.  Chromatographic silanol activity test procedures: the quest for a universal test. , 2000, Journal of chromatography. A.

[12]  Qian Wang,et al.  Surface confined ionic liquid as a stationary phase for HPLC. , 2006, The Analyst.

[13]  A. Berthod,et al.  Ionic liquids versus triethylamine as mobile phase additives in the analysis of beta-blockers. , 2006, Journal of chromatography. A.

[14]  J. H. Ayala,et al.  Determination of less polar heterocyclic amines in meat extracts: fast sample preparation method using solid-phase microextraction prior to high-performance liquid chromatography-fluorescence quantification. , 2007, Analytica chimica acta.

[15]  A. Berthod,et al.  Use of the ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate in countercurrent chromatography , 2004, Analytical and bioanalytical chemistry.

[16]  V. González,et al.  Exposure to heterocyclic aromatic amines from the consumption of cooked red meat and its effect on human cancer risk: A review , 2008, Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment.

[17]  N. Watanabe,et al.  Studies on mammary carcinogenesis induced by a heterocyclic amine, 2‐amino‐1‐methyl‐6‐phenylimidazo[4,5‐b]pyridine, in mice and rats , 2002, Environmental and molecular mutagenesis.

[18]  Jongki Hong,et al.  Simultaneous determination of anabolic steroids and synthetic hormones in meat by freezing-lipid filtration, solid-phase extraction and gas chromatography-mass spectrometry. , 2005, Journal of chromatography. A.

[19]  R. Kaliszan,et al.  Evaluation of the silanol-suppressing potency of ionic liquids. , 2006, Journal of separation science.

[20]  Liang Zhao,et al.  Effect of 1-alkyl-3-methylimidazolium-based ionic liquids as the eluent on the separation of ephedrines by liquid chromatography. , 2003, Journal of chromatography. A.

[21]  Y. Koo,et al.  Application of ionic liquids as mobile phase modifier in HPLC , 2006 .

[22]  R. Kaliszan,et al.  Application of Ionic Liquids in Liquid Chromatography , 2007 .

[23]  R. Turesky Formation and biochemistry of carcinogenic heterocyclic aromatic amines in cooked meats. , 2006, Toxicology letters.

[24]  Veronika R. Meyer,et al.  Practical High-Performance Liquid Chromatography , 1988 .

[25]  B. Lavine,et al.  Enhancement of selectivity in reversed-phase liquid chromatography. , 2002, Journal of chromatography. A.

[26]  D. Armstrong,et al.  Immobilized ionic liquids as high-selectivity/high-temperature/high-stability gas chromatography stationary phases. , 2005, Analytical chemistry.

[27]  M. Galceran,et al.  Evaluation of reversed-phase columns for the analysis of heterocyclic aromatic amines by liquid chromatography-electrospray mass spectrometry. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[28]  V. Pino,et al.  Focused Microwave‐Assisted Extraction and HPLC with Electrochemical Detection to Determine Heterocyclic Amines in Meat Extracts , 2007 .

[29]  R. Kaliszan,et al.  Suppression of deleterious effects of free silanols in liquid chromatography by imidazolium tetrafluoroborate ionic liquids. , 2004, Journal of chromatography. A.

[30]  J. H. Ayala,et al.  Experimental Design Optimization of Solid‐Phase Microextraction Conditions for the Determination of Heterocyclic Aromatic Amines by High‐Performance Liquid Chromatography , 2006 .

[31]  Lloyd R. Snyder,et al.  Practical HPLC method development , 1988 .

[32]  G. Gross,et al.  Quantitation of mutagenic/carcinogenic heterocyclic aromatic amines in food products. , 1992, Journal of chromatography.

[33]  A. Berthod,et al.  Nonmolecular solvents in separation methods: dual nature of room temperature ionic liquids. , 2005, Analytical chemistry.

[34]  G. Guiochon,et al.  Comparison of the performance of a few packing materials designed to minimize the thermodynamic band tailing of basic compounds in reversed-phase liquid chromatography. , 2008, Journal of chromatography. A.

[35]  M. Galceran,et al.  Heterocyclic amines in griddled beef steak analysed using a single extract clean-up procedure. , 2007, Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association.

[36]  D. Armstrong,et al.  Ionic liquids in separations. , 2007, Accounts of chemical research.

[37]  L. Snyder,et al.  Column selectivity in reversed-phase liquid chromatography. IV. Type-B alkyl-silica columns. , 2003, Journal of chromatography. A.

[38]  V. Pino,et al.  The ionic liquid 1-hexadecyl-3-methylimidazolium bromide as novel extracting system for polycyclic aromatic hydrocarbons contained in sediments using focused microwave-assisted extraction. , 2008, Journal of chromatography. A.

[39]  E. Soczewiński,et al.  The relation between the composition of certain ternary two-phase solvent systems and RM values , 1962 .

[40]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.