Efficiency optimization in ZVS series resonant inverters with asymmetrical voltage-cancellation control

This paper presents a time-domain analysis and a computerized search algorithm for optimizing the efficiency in zero-voltage switching (ZVS) full-bridge series resonant inverters with asymmetrical voltage-cancellation (AVC) control for different load quality factors. The optimum AVC control found allows all the switches to be turned on with zero voltage with the minimum switching frequency. In order to minimize losses, the switching frequency is kept as close as possible to resonance. The optimum AVC control is compared with previous fixed or narrow frequency range control strategies to show that it improves performance over all the output power range for different loads. The detailed steady-state analysis carried out here increases the precision of the first-harmonic analysis of a previous work, which is especially important with distorted output currents due to low load quality factors or highly asymmetrical modulation strategies. The theoretical results are verified experimentally.

[1]  F. Lee,et al.  Offline application of the fixed-frequency clamped-mode series resonant converter , 1991 .

[2]  F. C. Lee,et al.  Control system design and small-signal analysis of a phase-shift-controlled series-resonant inverter for induction heating , 1995, Proceedings of PESC '95 - Power Electronics Specialist Conference.

[3]  Dariusz Czarkowski,et al.  Phase-controlled series-parallel resonant converter , 1993 .

[4]  J. A. Sabate,et al.  Design of a 10 kW, 500 kHz phase-shift controlled series-resonant inverter for induction heating , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[5]  Fred C. Lee,et al.  Constant-frequency, clamped-mode resonant converters , 1987, IEEE Power Electronics Specialists Conference.

[6]  M. Kazimierczuk,et al.  Phase control of series resonant converter , 1993, Proceedings of IEEE Power Electronics Specialist Conference - PESC '93.

[7]  N. Mohan,et al.  Asymmetrical duty cycle permits zero switching loss in PWM circuits with no conduction loss penalty , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[8]  Praveen Jain,et al.  Asymmetrical Pulse-Width-Modulated , 1996 .

[9]  J. A. Sabate,et al.  Off-line application of the fixed frequency clamped mode series-resonant converter , 1989, Proceedings, Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[10]  Phua Chee Heng,et al.  Soft-switched DC/DC converter with PWM control , 1993, Proceedings of Intelec 93: 15th International Telecommunications Energy Conference.

[11]  Ned Mohan,et al.  New directions in DC-DC power conversion based on idealized concepts leading ultimately to the asymmetrical duty-cycle power converter , 1997 .

[12]  M. Kazimierczuk Synthesis of phase-modulated resonant DC/AC inverters and DC/DC convertors , 1992 .

[13]  Mehrdad Ehsani,et al.  A review of soft-switched DC-AC converters , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[14]  J.M. Burdio,et al.  Comparison study of fixed-frequency control strategies for ZVS DC/DC series resonant converters , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[15]  J. Acero,et al.  Asymmetrical voltage-cancellation control for full-bridge series resonant inverters , 2004, IEEE Transactions on Power Electronics.

[16]  M. Kazimierczuk,et al.  Resonant Power Converters , 1995 .