Functional near infrared spectroscopy for awake monkey to accelerate neurorehabilitation study

Functional near-infrared spectroscopy (fNIRS) is suitable for measuring brain functions during neurorehabilitation because of its portability and less motion restriction. However, it is not known whether neural reconstruction can be observed through changes in cerebral hemodynamics. In this study, we modified an fNIRS system for measuring the motor function of awake monkeys to study cerebral hemodynamics during neurorehabilitation. Computer simulation was performed to determine the optimal fNIRS source–detector interval for monkey motor cortex. Accurate digital phantoms were constructed based on anatomical magnetic resonance images. Light propagation based on the diffusion equation was numerically calculated using the finite element method. The source–detector pair was placed on the scalp above the primary motor cortex. Four different interval values (10, 15, 20, 25 mm) were examined. The results showed that the detected intensity decreased and the partial optical path length in gray matter increased with an increase in the source-detector interval. We found that 15 mm is the optimal interval for the fNIRS measurement of monkey motor cortex. The preliminary measurement was performed on a healthy female macaque monkey using fNIRS equipment and custom-made optodes and optode holder. The optodes were attached above bilateral primary motor cortices. Under the awaking condition, 10 to 20 trials of alternated single-sided hand movements for several seconds with intervals of 10 to 30 s were performed. Increases and decreases in oxy- and deoxyhemoglobin concentration were observed in a localized area in the hemisphere contralateral to the moved forelimb.

[1]  Eiji Okada,et al.  Effect of probe arrangement on reproducibility of images by near-infrared topography evaluated by a virtual head phantom. , 2007, Applied optics.

[2]  S R Arridge,et al.  Direct calculation of the moments of the distribution of photon time of flight in tissue with a finite-element method. , 1995, Applied optics.

[3]  Ichiro Miyai,et al.  Review of functional near-infrared spectroscopy in neurorehabilitation , 2016, Neurophotonics.

[4]  A Taddeucci,et al.  Optical properties of brain tissue. , 1996, Journal of biomedical optics.

[5]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[6]  M. Schweiger,et al.  Photon-measurement density functions. Part 2: Finite-element-method calculations. , 1995, Applied optics.

[7]  M. Schweiger,et al.  Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head. , 1997, Applied optics.

[8]  Thierry Wannier,et al.  Can experiments in nonhuman primates expedite the translation of treatments for spinal cord injury in humans? , 2007, Nature Medicine.

[9]  Joseph T. Francis,et al.  Use of Frontal Lobe Hemodynamics as Reinforcement Signals to an Adaptive Controller , 2013, PloS one.

[10]  D T Delpy,et al.  Measurement of the optical properties of the skull in the wavelength range 650-950 nm , 1993, Physics in medicine and biology.

[11]  Tadashi Isa,et al.  Temporal Plasticity Involved in Recovery from Manual Dexterity Deficit after Motor Cortex Lesion in Macaque Monkeys , 2015, The Journal of Neuroscience.

[12]  M. Kohl,et al.  Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. , 1998, Physics in medicine and biology.

[13]  M. Schweiger,et al.  A finite element approach for modeling photon transport in tissue. , 1993, Medical physics.

[14]  Arthur W. Toga,et al.  Near-infrared spectroscopy (NIRS) in cognitive neuroscience of the primate brain , 2005, NeuroImage.

[15]  Wim Vanduffel,et al.  Fast optical signal not detected in awake behaving monkeys , 2008 .

[16]  D. Delpy,et al.  Near-infrared light propagation in an adult head model. I. Modeling of low-level scattering in the cerebrospinal fluid layer. , 2003, Applied optics.